Experimental Study of Cold-Formed Steel Built-Up Beams
Publication: Journal of Structural Engineering
Volume 146, Issue 7
Abstract
This paper describes a comprehensive experimental program on cold-formed steel built-up beams with two different cross-sectional geometries. The work aimed to experimentally investigate the interaction between the individual components under increasing loading and to quantify the effect of the connector spacing on the cross-sectional moment capacity and the behavior of the beams. In total, 12 specimens were tested in a four-point bending configuration, with lateral restraints provided at the loading points in order to avoid global instabilities. The built-up specimens were composed of three or four plain channels with nominal thicknesses of 1.2 and 1.5 mm, which were joined together using M6 bolts. Each built-up geometry was tested with three different connector spacings. The specimens were designed to fail by local buckling of their components. Additionally, strut buckling of the channel comprising the top flange in between connector points was observed. The local buckling deformations and the beam deflections were recorded during the tests. The material properties of the test specimens were determined by means of coupon tests and the geometric imperfections were measured prior to testing. The experimental results showed clear evidence of interaction between the local buckling patterns of the components, with the interaction being affected by the connector spacing and the type of geometry. However, the connector spacing showed a less significant effect on the ultimate capacity when failure was governed by local instabilities of the components.
Get full access to this article
View all available purchase options and get full access to this article.
Data Availability Statement
Some or all data, models, or code generated or used during the study are available from the corresponding author by request, including material properties data, geometric imperfections data, connector behavior data, and out-of-plane deformation data.
Acknowledgments
The authors are grateful for the financial support provided by the EPSRC through Grant No. EP/M011976/1.
References
AISI (American Iron and Steel Institute). 2016. North American specification for the design of cold-formed steel structural members. AISI S136. Toronto: AISI.
Becque, J. 2014. “Local-overall interaction buckling of inelastic columns: A numerical study of the inelastic Van der Neut column.” Thin Walled Struct. 81 (Aug): 101–107. https://doi.org/10.1016/j.tws.2013.07.010.
Blum, H. B., and K. J. R. Rasmussen. 2019. “Experimental investigation of long-span cold-formed steel double channel portal frames.” J. Constr. Steel Res. 155 (Apr): 316–330. https://doi.org/10.1016/j.jcsr.2018.11.020.
CEN (European Committee for Standardization). 2004. Continuously hot-dip coated strip and sheet of structural steels—Technical delivery conditions. EN 10326. Brussels, Belgium: CEN.
CEN (European Committee for Standardization). 2005. Design of steel structures, Part 1.1: General rules and rules for buildings. EN 1993-1-1. Brussels, Belgium: CEN.
CEN (European Committee for Standardization). 2016. Designation systems for steels, Part 1: Steel names. EN 10024-1. Brussels, Belgium: CEN.
Dang, K. P., and K. J. R. Rasmussen. 2019. “Flexural rigidity of cold-formed steel built-up members.” Thin Walled Struct. 140 (Jul): 438–449. https://doi.org/10.1016/j.tws.2019.03.051.
Di Lorenzo, G., F. Portioli, and R. Landolfo. 2004. “On the characterization of the material properties for cold-formed steel members.” In Proc., 4th Int. Conf. on Thin-Walled Structures, 251–258. Loughborough, UK.
Di Lorenzo, G., F. Portioli, and R. Landolfo. 2006. “Experimental investigation on the load bearing capacity of built-up cold-formed steel beams.” In Proc., Int. Colloquium on Stability and Ductility of Steel Structures. Lisbon, Portugal.
Dubina, D., A. Stratan, and Z. Nagy. 2009. “Full-scale tests on cold-formed steel pitched-roof portal frames with bolted joints.” Adv. Steel Constr. 5 (2): 175–194.
ECCS TC. 2009. The testing of connections with mechanical fasteners in steel sheeting and sections. Brussels, Belgium: European Convention for Constructional Steelwork Technical Committee.
Jeyaragan, S., and M. Mahendran. 2008a. “Experimental investigation of the new built-up LiteSteel beams.” In Proc., 5th Int. Conf. on Thin-Walled Structures. Brisbane, Australia.
Jeyaragan, S., and M. Mahendran. 2008b. “Numerical modelling and design of the new built-up LiteSteel beams.” In Proc., 5th Int. Conf. on Coupled Instabilities in Metal Structures, Sydney, Australia.
Landolfo, R., O. Mammana, F. Portioli, G. Di Lorenzo, and M. R. Guerrieri. 2008. “Laser welded built-up cold-formed steel beams: Experimental investigations.” Thin Walled Struct. 46 (7–9): 781–791. https://doi.org/10.1016/j.tws.2008.03.009.
Landolfo, R., O. Mammana, F. Portioli, G. Di Lorenzo, and M. R. Guerrieri. 2009. “Experimental investigation on laser welded connections for built-up cold-formed steel beams.” J. Constr. Steel Res. 65 (1): 196–208. https://doi.org/10.1016/j.jcsr.2008.03.015.
Lim, J. B. P., and D. A. Nethercot. 2002. “Design and development of a general cold-formed steel portal framing system.” Struct. Eng. 80 (21): 31–39.
Meza, F., S. Cheng, J. Becque, and I. Hajirasouliha. 2016. “Experimental investigation of the cross-sectional stability of cold-formed steel built-up columns.” In Proc., Int. Colloquium on Stability and Ductility of Steel Structures SDSS2016. Timisoara, Romania.
Meza, F. J. 2018. “The behaviour of cold-formed steel built-up structural members.” Ph.D. thesis, Dept. of Civil and Structural Engineering, Univ. of Sheffield.
Meza, F. J., J. Becque, and I. Hajirasouliha. 2020. “Experimental study of cold-formed steel built-up columns.” Thin Walled Struct. 140: 106291. https://doi.org/10.1016/j.tws.2019.106291.
Portioli, F., G. Di Lorenzo, R. Landolfo, and F. M. Mazzolani. 2012. “Contact buckling effects in built-up cold-formed steel beams.” Proc., 6th Int. Conf. on Coupled Instabilities in Metal Structures, 1–8. Glasgow, Scotland.
Schafer, B. W. 2006. “Buckling analysis of cold-formed steel members using CUFSM: Conventional and constrained finite strip methods.” In Proc., 18th Int. Specialty Conf. on Cold-Formed Steel Structures. Orlando, Florida.
Timoshenko, S. 1940. Strength of materials—Part 1: Elementary theory and problems. 2nd ed. New York: D. Van Nostrand Company.
Van der Neut, A. 1969. “The interaction of local buckling and column failure of thin-walled compression members.” In Proc., 12th Int. Congress of Applied Mechanics, 389–399. Delft, Netherlands: Delft Univ. of Technology.
Venkataramaiah, K. R., and J. Roorda. 1982. “Analysis of local plate buckling experimental data.” In Proc., 6th Int. Specialty Conf. on Cold-Formed Steel Structures, 45–73. St. Louis, MO.
Wang, L., and B. Young. 2015. “Beam tests of cold-formed steel built-up sections with web perforations.” J. Constr. Steel Res. 115 (Dec): 18–33. https://doi.org/10.1016/j.jcsr.2015.08.001.
Wang, L., and B. Young. 2016a. “Behavior of cold-formed steel built-up sections with intermediate stiffeners under bending. I: Tests and numerical validation.” J. Struct. Eng. 142 (3): 04015150. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001428.
Wang, L., and B. Young. 2016b. “Behavior of cold-formed steel built-up sections with intermediate stiffeners under bending. II: Parametric study and design.” J. Struct. Eng. 142 (3): 04015151. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001427.
Zhang, X., and K. Rasmussen. 2014. “Tests of cold-formed steel portal frames with slender sections.” Steel Constr. 7 (3): 199–203. https://doi.org/10.1002/stco.201410030.
Information & Authors
Information
Published In
Copyright
©2020 American Society of Civil Engineers.
History
Received: Jul 17, 2019
Accepted: Jan 27, 2020
Published online: Apr 25, 2020
Published in print: Jul 1, 2020
Discussion open until: Sep 25, 2020
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.