Test of a Steel Plate Shear Wall with Partially Encased Composite Columns and RBS Frame Connections
Publication: Journal of Structural Engineering
Volume 144, Issue 2
Abstract
A large-scale steel plate shear wall with partially encased composite (PEC) columns and reduced beam section (RBS) frame connections was tested at the University of Alberta to investigate the behavior of the system and quantify some key characteristics related to seismic design of this system. The use of RBS connections was intended to reduce the demand on the beam-to-column connection and obtain improved seismic performance. Subjected to quasi-static cyclic load until severe damage was observed, the specimen showed desirable characteristics such as high elastic lateral stiffness, ductility, and energy dissipation capacity. The use of RBS frame connections was proven to be a viable option to improve the seismic performance of these walls. The test observations indicated that the detailing of the PEC columns played an important role in improving the seismic performance of the specimen. Several design and detailing recommendations have been made based on the observations during this test and previous experimental studies.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
Funding for this study was provided by the Natural Sciences and Engineering Research Council of Canada and the Canam Group. The first author received financial support in the form of scholarships from Alberta Innovates and the University of Alberta. Lehigh Inland Cement Limited provided the required concrete for this research.
References
AISC. (2010). “Seismic provisions for structural steel buildings.” ANSI/AISC 341-10, Chicago.
ATC (Applied Technology Council). (1992). “Guidelines for cyclic seismic testing of components of steel structures.”, Redwood City, CA.
Begum, M., Driver, R. G., and Elwi, A. E. (2007). “Finite-element modeling of partially encased composite columns using the dynamic explicit method.” J. Struct. Eng., 326–334.
Bouchereau, R., and Toupin, J. D. (2003). “Étude du comportement en compression-flexion des poteaux mixtes partiellement enrobés.”, École Polytechnique, Montreal (in French).
Chicoine, T., Massicotte, B., and Tremblay, R. (2002a). “Finite element modelling and design of partially encased composite columns.” Steel Compos. Struct., 2(3), 171–194.
Chicoine, T., Tremblay, R., Massicotte, B., Ricles, J., and Lu, L. W. (2002b). “Behaviour and strength of partially encased composite columns with built up shapes.” J. Struct. Eng., 279–288.
CSA (Canadian Standards Association). (2014). “Design of steel structures.” CSA S16-14, Mississauga, ON, Canada.
Dastfan, M., and Driver, R. G. (2008). “Flexural stiffness limits for frame members of steel plate shear wall systems.” Proc., 2008 Annual Stability Conf., Univ. of Missouri-Rolla, Rolla, MO, 321–334.
Dastfan, M., and Driver, R. G. (2009). “Investigations on the effect of frame member connection rigidity on the behavior of steel plate shear wall systems.” Proc., STESSA 2009 Behaviour of Steel Structures in Seismic Areas, Taylor and Francis Group, London, 231–235.
Dastfan, M., and Driver, R. G. (2016). “Large-scale test of a modular steel plate shear wall with partially encased composite columns.” J. Struct. Eng., 04015142.
Deng, X., Dastfan, M., and Driver, R. G. (2008). “Behaviour of steel plate shear walls with composite columns.” Proc., American Society of Civil Engineers Structures Congress, ASCE, Reston, VA.
Deng, X., and Driver, R. G. (2007). “Steel plate shear walls with partially encased composite columns.” Proc., Structural Stability Research Council Annual Stability Conf., Univ. of Missouri-Rolla, Rolla, MO, 437–453.
Grubbs, K. V. (1997). “The effect of dogbone connection on the elastic stiffness of steel moment frames.” M.Sc. thesis, Univ. of Texas at Austin, Austin, TX.
Moore, K. S., Malley, J. O., and Engelhardt, M. D. (1999). “Design of reduced beam section (RBS) moment frame connections.” Steel tips, Structural Steel Educational Council, Moraga, CA.
Prickett, B. S., and Driver, R. G. (2006). “Behavior of partially encased composite columns made with high performance concrete.”, Univ. of Alberta, Edmonton, AB, Canada.
Qu, B., and Bruneau, M. (2010). “Capacity design of intermediate horizontal boundary elements of steel plate shear walls.” J. Struct. Eng., 665–675.
Tremblay, R., Massicotte, B., Filion, I., and Maranda, R. (1998). “Experimental study on the behaviour of partially encased composite columns made with light welded H steel shapes under compressive axial loads.” Proc., 1998 Structural Stability Research Council Annual Technical Meeting, Univ. of Florida, Gainesville, FL, 195–204.
Tremblay, R., Tirca, L., Bouchereau, R., Toupin, J. D., and Massicotte, B. (2003). “Flexural demand on partially-encased composite columns in multi-story concentrically braced steel frames.” Proc., STESSA 2003 Behavior of Steel Structures in Seismic Areas, A.A. Balkema, Rotterdam, Netherlands, 479–485.
Vincent, R., and Tremblay, R. (2001). “An innovative partially encased composite column system for high-rise buildings.” Proc., North American Conf. on Steel Construction, AISC, Chicago, 30-3–30-17.
Information & Authors
Information
Published In
Copyright
©2017 American Society of Civil Engineers.
History
Received: Feb 26, 2017
Accepted: Jul 21, 2017
Published online: Nov 17, 2017
Published in print: Feb 1, 2018
Discussion open until: Apr 17, 2018
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.