Investigation of Steel Column–Baseplate Connection Details Incorporating Ductile Anchors
Publication: Journal of Structural Engineering
Volume 143, Issue 8
Abstract
It is widely accepted that the behavior of steel column–baseplate connections will profoundly impact the seismic response of steel buildings and other structures. Previous investigations into moment-frame steel column–baseplate connections have focused on the relationship between global metrics such as connection strength and stiffness to basic design parameters such as anchor arrangement and size, baseplate thickness, and column size. However, there is growing recognition that other details, such as the column setting method, baseplate hole size, anchor material selection, and anchor stretch length may significantly affect connection performance. This paper describes nine full-scale connection tests exploring the effects of such details on strength, rotation capacity, and postyield behavior. A comparison of the present with a prior test program on the basis of physical damage evolution and moment-rotation behavior is undertaken. The baseplate setting arrangement and anchor stretch length were found to have the most pronounced impact on the connection cyclic moment-rotation response. Suggestions for connection details that promote connection robustness, ductility, and strength are presented.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
Hilti Corporation funded this research with material and technical assistance provided also by Hilti North America. The authors gratefully acknowledge the support of these organizations. The authors would also like to thank Dr. Ulrich Bourgund, Dr. Philipp Grosser, Dr. Roberto Piccinin, Mr. John Silva, and Mr. Matteo Copellini for their input, as well as the staff of the UCSD Powell Laboratories for their assistance during testing. Opinions, findings, and conclusions are those of the authors, and do not necessarily reflect the views of the sponsoring organizations.
References
Abrishami, H., and Mitchell, D. (1996). “Analysis of bond stress distributions in pullout specimens.” J. Struct. Eng., 255–261.
ACI (American Concrete Institute). (2014). “Building code requirements for structural concrete and commentary.” ACI 318R-14, Farmington Hills, MI.
ASTM. (2007). “Standard specification for anchor bolts, Steel, 36, 55, and 105-ksi Yield Strength.” ASTM F1554-07ae1, West Conshohocken, PA.
ASTM. (2014a). “Standard specification for alloy-steel and stainless steel bolting for high temperature or high pressure service and other special purpose applications.” ASTM A193/A193M-14, West Conshohocken, PA.
ASTM. (2014b). “Standard specification for carbon structural steel.” ASTM A36/A36M-14, West Conshohocken, PA.
ASTM. (2015). “Standard specification for structural steel shapes.” ASTM A992/A992M-11, West Conshohocken, PA.
Clark, P., Frank, K., Krawinkler, H., and Shaw, R. (1997). “Protocol for fabrication, inspection, testing, and documentation for beam column connection tests and other experimental specimens.”, SAC Joint Venture, Sacramento, CA.
Fahmy, M. (1999). “Seismic behavior of moment-resisting steel column bases.” Ph.D. dissertation, Dept. of Civil and Environmental Engineering, Univ. of Michigan, Ann Arbor, MI.
Fisher, J. M., and Kloiber, L. A. (2006). Design guide 1: Base plate and anchor rod design, 2nd Ed., American Institute of Steel Construction, Chicago.
Gomez, I., Deierlein, G., and Kanvinde, A. (2010). Exposed column base connections subjected to axial compression and flexure, American Institute of Steel Construction, Chicago.
Grauvilardell, J., Lee, D., Hajjar, J., and Dexter, R. (2005) “Synthesis of design, testing, and research on steel column base connections in high-seismic zones.”, Univ. of Minnesota Structural Engineering, Minneapolis.
Kanvinde, A., Grilli, D., and Zareian, F. (2012). “Rotational stiffness of exposed column base connections: Experiments and analytical models.” J. Struct. Eng., 549–560.
Krawinkler, H., Gupta, A., Medina, R., and Luco, N. (2000). “Development of loading histories for testing of steel beam-to-column assemblies.” ⟨http://ssdaslottedweb.com/tech_loadhistory.pdf⟩ (Sep. 7, 2016).
Salmon, C. G., Shaker, L., and Johnston, B. G. (1957). “Moment-rotation characteristics of column anchorages.” Trans. ASCE, 122, 132–154.
Trautner, C., and Hutchinson, T. (2016). “Structural base plate connection component testing—Phase II Part 2: Data analysis, modeling, and conclusions.”, Univ. of California, San Diego.
Trautner, C., Hutchinson, T., Copellini, M., Grosser, P., Bachman, R., and Silva, J. (2016). Developing ductility using concrete anchorage, American Concrete Institute, Farmington Hills, MI.
Trautner, C., Hutchinson, T. C., Grosser, P, and Silva, J. (2016). “Effects of connection detailing on the cyclic behavior of steel baseplate connections.” J. Struct. Eng., .
Information & Authors
Information
Published In
Copyright
©2017 American Society of Civil Engineers.
History
Received: May 7, 2016
Accepted: Nov 18, 2016
Published online: Mar 29, 2017
Published in print: Aug 1, 2017
Discussion open until: Aug 29, 2017
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.