Testing and Modeling of Wood–Masonry Hybrid Wall Assembly
Publication: Journal of Structural Engineering
Volume 143, Issue 2
Abstract
Reinforced concrete or masonry cores commonly exist in multistory light wood frame buildings (LWFBs) as elevator shafts and stairwells. These cores are often not accounted for in structural design as part of the lateral load resisting system in combination with the light wood frame subsystem due to the uncertainty regarding material compatibility. In this paper, the interaction between the wood frame and masonry walls in a hybrid lateral load resisting wall system was investigated using a two-dimensional numerical model. Two two-story hybrid wood-masonry walls as well as individual wall subsystems and connections were tested experimentally under reversed cyclic loading to provide confidence in the ability of the numerical model to predict the lateral load response of the hybrid wall systems. From the experimental results it was noted that the bolted connections first failed when the load was applied to the wood frame in the hybrid system, while masonry walls first failed when the load was applied to the masonry wall. The results show that as displacement increases, the load shared by the wood subsystem was reduced due to progressive softening of wood shear wall specimens. When the load was applied to the wood frame subsystem the connections did contribute to the energy dissipation of the whole hybrid wall system. When the load was applied to the stiffer masonry wall, the energy dissipation by the connections can be ignored.
Get full access to this article
View all available purchase options and get full access to this article.
References
ABAQUS version 6.10 [Computer software]. Dassault Systemes Simulia, Providence, RI.
APEGBC (Association of Professional Engineers and Geoscientists of BC). (2009). “Technical and practice bulletin—Structural, fire protection and building envelope professional engineering services for 5 and 6 story wood frame residential building projects (mid-rise buildings).” Vancouver, BC, Canada.
Ash, C., Aschheim, M., Mar, D., and King, B. (2004). “Reversed cyclic in-plane tests of load-bearing plastered straw bale walls.” Proc., 13th World Conf. of Earthquake Engineering, Canadian Association for Earthquake Engineering, Vancouver, BC, 1–5.
Asiz, A., Chui, Y. H., Ni, C., Mohammad, M., and Doudak, G. (2011). “Seismic performance of multi-story light wood frame buildings with hybrid bracing systems.” Proc., Canadian Society for Civil Engineering, Curran Associates, Red Hook, NY.
Beattie, G. J. (1999). “Earthquake load sharing between timber framed and masonry walls.” Proc., Pacific Timber Engineering Conf., New Zealand Forest Research Institute, Rotorua, NZ.
Blaylock, J. R. (2012). “Wood infill walls in reinforced concrete frame structures: A wood/concrete construction niche.” Ph.D. thesis, Univ. of Western Ontario, London, ON.
CSA (Canadian Standards Association). (2004). “Design of masonry structures.”, Mississauga, ON, Canada.
CSA (Canadian Standards Association). (2009). “Engineering design in wood.”, Toronto, ON, Canada.
Guo, S., He, M., and Ni, C. (2014). “Seismic analysis of hybrid multi-story light wood frames in China.” Proc., 13th World Conf. on Timber Engineering, FPInnovations, Quebec, QC.
He, M., Lam, F., and Prion, H. G. (1998). “Influence of cyclic test protocols on performance of wood-based shear walls.” Can. J. Civ. Eng., 25(3), 539–550.
He, M., Li, Z., Lam, F., Ma, R., and Ma, Z. (2014). “Experimental investigation on lateral performance of timber-steel hybrid shear wall systems.” J. Struct. Eng., 04014029.
Källsner, B., and Lam, F. (1995). “Diaphragms and shear walls.” Holzbauwerke nach Eurocode 5—Step 3, Düsseldorf, Germany, 15-1–15-19.
Li, Z., He, M., Lam, F., Li, M., Ma, R., and Ma, Z. (2014). “Finite element modeling and parametric analysis of timber-steel hybrid structures.” Struct. Design Tall Special Build., 23(14), 1045–1063.
Schwartz, J., Mojsilović, N., Becker, C., and Curiger, P. (2011). “Cyclic shear load tests on seismically strengthened masonry walls.” Proc., 11th North American masonry Conf., Masonry Society, Boulder, CO, 1331–42.
Wang, Q. (2009). “Relationship between fastening properties and load-deflection response of wood shear walls.” M.Sc. thesis, Univ. of New Brunswick, Fredericton, NB.
Xiong, H., and Jia, G. (2008). “Research on seismic behavior of wood-concrete hybrid structure.” Proc., 10th World Conf. on Timber Engineering, Curran Associates, Red Hook, NY.
Xu, J. (2006). “Development of a general dynamic hysteretic light-frame structure model and study on the torsional behavior of open-front light-frame structures.” Ph.D. dissertation, Washington State Univ., Pullman, WA.
Xu, J., and Dolan, J. D. (2009). “Development of nailed wood joint element in ABAQUS.” J. Struct. Eng., 968–976.
Information & Authors
Information
Published In
Copyright
© 2016 American Society of Civil Engineers.
History
Received: Jan 12, 2016
Accepted: Jul 18, 2016
Published online: Sep 2, 2016
Published in print: Feb 1, 2017
Discussion open until: Feb 2, 2017
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.