Stainless Steel Grids for Confinement of Clay Brick Masonry Columns
Publication: Journal of Structural Engineering
Volume 142, Issue 7
Abstract
This work presents the results of an experimental investigation on the behavior of 21 solid clay brick columns internally strengthened by stainless steel grids placed in the horizontal joints of mortar. This reinforcing technique can be applied as a constructive technique for new construction or as a retrofitting technique for existing structures (old structures to be reconstructed by original constructive method and internal reinforcement). Monotonic compressive loading tests were carried out under concentric and eccentric load. The effects of different numbers of steel grids and eccentricity of the external load were examined. Also, a detailed characterization of the constituent materials was made experimentally. The compression tests show the effectiveness of the proposed strengthening technique, which proves to be able to produce the increases in strength and energy required to collapse brick columns under both concentric and eccentric loads. To provide an analysis method for practical applications, an analytical expression is proposed that gives the strength value of confined brick columns by considering that the biaxial strength domain of the bricks is modified due to the tensile contribution offered by the presence of steel grids. Moreover, moment-axial force domains, derived using the plane cross section theory, are calibrated on the basis of the compressive strength values experimentally detected.
Get full access to this article
View all available purchase options and get full access to this article.
References
Aiello, M., Micelli, F., and Valente, L. (2009). “FRP confinement of square masonry columns.” J. Compos. Constr., 148–158.
ASTM. (2014). “Standard test method for compressive strength of masonry prisms.” ASTM C1314, West Conshohocken, PA.
Binda, L., Saisi, A., and Tiraboschi, C. (2000). “Investigation procedures for the diagnosis of historic masonries.” Constr. Build. Mater., 14(4), 199–233.
Borri, A., Castori, G., and Corradi, M. (2011). “Masonry confined by steel fiber-composite wraps.” Materials, 4(12), 311–326.
Brencich, A., Corradi, C., and Gambarotta, L. (2008). “Eccentrically loaded brickwork: Theoretical and experimental results.” Eng. Struct., 30(12), 3629–3643.
Campione, G., Granata, M. F., and Cucchaira, C. (2014). “Strengthening of solid brick masonry columns with joints collared by steel wires.” J. Civ. Eng. Sci., 3(3), 171–179.
Cavaleri, L., Failla, A., La Mendola, L., and Papia, M. (2005). “ Experimental and analytical response of masonry elements under eccentric vertical loads.” Eng. Struct., 27(8), 1175–1184.
Cavaleri, L., Fossetti, M., and Papia, M. (2009). “Modelling of out-of-plane behaviour of masonry walls.” J. Struct. Eng., 135(12), 1522–1532.
CEB (Comite Euro-international du Beton). (1993). “CEB-FIP model code 1990: Design code.” Thomas Telford, London.
Corradi, M., Borri, A., and Grazini, A. (2007). “Confinement of brick masonry columns with CFRP materials.” Compos. Sci. Technol., 67(9), 1772–1783.
Corradi, M., Borri, A., and Vignoli, A. (2002). “Strengthening techniques tested on masonry structures struck by the Umbria-Marche earthquake of 1997-1998.” Constr. Build. Mater., 16(4), 229–239.
Di Ludovico, M., D’Ambra, C., Prota, A., and Manfredi, G. (2010). “FRP confinement of tuff and clay brick columns: Experimental study and assessment of analytical models.” J. Compos. Constr., 583–596.
Ewing, B. D., and Kowalsky, M. J. (2004). “Compressive behaviour of unconfined and confined clay brick masonry.” J. Struct. Eng., 650–661.
Jurina, L. (2009). “Collapse tests on masonry externally wrapped.” Proc., IF CRASC 09, AIF (Italian Association of Forensic Engineering), Napoli, Italy.
Krevaikas, T. D., and Triantafillou, T. C. (2005). “Masonry confinement with fiber-reinforced polymers.” J. Compos. Constr., 128–135.
McNary, W. S., and Abrams, D. P. (1985). “Mechanics of masonry in compression.” J. Struct. Eng., 857–870.
Priestley, M. J. N., and Bridgeman, D. O. (1974). “Seismic resistance of brick masonry walls.” Bull. New Zealand National Soc. Earthquake Eng., 7(4), 167–187.
Priestley, M. J. N., and Elder, D. M. (1983). “Stress-strain curves for unconfined and confined masonry.” ACI J., 80(3), 192–201.
TestXpert v.7.11 [Computer software]. Zwick, Ulm, Germany.
Information & Authors
Information
Published In
Copyright
© 2016 American Society of Civil Engineers.
History
Received: Mar 23, 2015
Accepted: Jan 8, 2016
Published online: Feb 29, 2016
Published in print: Jul 1, 2016
Discussion open until: Jul 29, 2016
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.