Seismic Performance Evaluation of Posttensioned Hybrid Precast Wall-Frame Buildings and Comparison with Shear Wall-Frame Buildings
Publication: Journal of Structural Engineering
Volume 142, Issue 6
Abstract
Seismic performance of posttensioned hybrid precast wall systems has been mainly studied in the past without considering the interaction of the wall system with the rest of the structure. In the present study, the multilevel seismic response of posttensioned hybrid precast wall-frame (PWF) buildings is evaluated using nonlinear response history analysis and compared with the response of shear wall-frame (SWF) buildings under unidirectional excitation. For that purpose, three-dimensional finite-element models of code-compliant 4- and 8-story PWF and SWF buildings designed with different frame shear ratios are considered. The performance of buildings is evaluated under spectrum-matched earthquake motions to represent two levels of shaking viz the design earthquake (DE) level and the risk-targeted maximum considered earthquake () level. The effect of the vertical component of earthquake motion on the peak response indicators of both types of buildings is also studied. It is determined that the seismic performance of PWF buildings is superior to SWF buildings in terms of limiting structural damage under the DE-level and the -level ground motions, despite the relatively larger roof drifts observed in the PWF buildings; however, nonstructural damage caused by floor accelerations is more pronounced in the PWF buildings. In addition, it is determined that the inclusion of the vertical component of earthquake motion does not significantly affect the peak response indicators of the PWF and SWF buildings considered in this study.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The first author gratefully acknowledges a Monbukagakusho (Ministry of Education, Culture, Sports, Science, and Technology, Japan) scholarship for graduate students. The authors are grateful to the anonymous reviewers for helpful suggestions, which have considerably improved this manuscript.
References
ACI (American Concrete Institute). (2009). “Design of a special unbonded post-tensioned precast shear wall satisfying ACI ITG-5.1 requirements.”, ACI Innovation Task Group 5, Detroit.
ACI (American Concrete Institute). (2011). “Building code requirements for structural concrete and commentary.”, Detroit.
Ajrab, J., Pekcan, G., and Mander, J. (2004). “Rocking wall-frame structures with supplemental tendon systems.” J. Struct. Eng., 895–903.
ASCE. (2010). “Minimum design loads for buildings and other structures.”, Reston, VA.
Bailey, S., Dizhur, D., Trowsdale, J., Griffith, M., and Ingham, J. M. (2014). “Performance of posttensioned seismic retrofit of two stone masonry buildings during the Canterbury earthquakes.” J. Perform. Constr. Facil., 04014111.
Bean, J. R., Schultz, A. E., and Drake, C. R. (2007). “Behavior of slender, post-tensioned masonry walls under transverse loading.” J. Struct. Eng., 1541–1550.
Belleri, A., Schoettler, M. J., Restrepo, J. I., and Fleischman, R. B. (2014). “Dynamic behavior of rocking and hybrid cantilever walls in a precast concrete building.” ACI Struct. J., 111(3), 661–672.
Calugaru, V., and Panagiotou, M. (2014). “Seismic response of 20-story base-isolated and fixed-base reinforced concrete structural wall buildings at a near-fault site.” Earthquake Eng. Struct. Dyn., 43(6), 927–948.
Chang, G. A., and Mander, J. B. (1994). “Seismic energy based fatigue damage analysis of bridge columns: Part 1—Evaluation of seismic capacity.”, State Univ. of New York, Buffalo, NY.
Cheok, G. S., Stone, W. C., and Nakaki, S. D. (1996). “Simplified design procedure for hybrid precast concrete connections.”, National Institute of Standards and Technology, Gaithersburg, MD.
FEMA. (2009). “NEHRP recommended seismic provisions for new buildings and other structures.”, Prepared by National Institute of Building Sciences Building Seismic Safety Council, Washington, DC.
Hancock, J., et al. (2006). “An improved method of matching response spectra of recorded earthquake ground motion using wavelets.” J. Earthquake Eng., 10, 67–89.
Henry, R. S., Ingham, J. M., and Sritharan, S. (2012). “Wall-to-floor interaction in concrete buildings with rocking wall systems.” NZSEE Conf., Christchurch, New Zealand, 72.
Holden, T., Restrepo, J., and Mander, J. B. (2003). “Seismic performance of precast reinforced and prestressed concrete walls.” J. Struct. Eng., 286–296.
Kabeyasawa, T., Shiohara, H., Otani, S., and Aoyama, H. (1983). “Analysis of the full-scale seven-story reinforced concrete test structure.” J. Faculty Eng., 37(2), 431–478.
Kim, J. S., and Elnashai, A. S. (2009). “Characterization of shaking intensity distribution and seismic assessment of RC buildings for the Kashmir (Pakistan) earthquake of October 2005.” Eng. Struct., 31(12), 2998–3015.
Kurama, Y. (2002). “Hybrid post-tensioned precast concrete walls for use in seismic regions.” PCI J., 47(5), 36–59.
Marriott, D., Pampanin, S., Bull, D., and Palermo, A. (2008). “Dynamic testing of precast, post-tensioned rocking wall systems with alternative dissipating solutions.” Bull. N. Z. Soc. Earthquake Eng., 41(2), 90–103.
Marriott, D., Pampanin, S., and Palermo, A. (2011). “Biaxial testing of unbonded post-tensioned rocking bridge piers with external replaceable dissipaters.” Earthquake Eng. Struct. Dyn., 40(15), 1723–1741.
Menegotto, M., and Pinto, P. (1973). “Methods of analysis for cyclically loaded R/C frames.” Proc., Symp. of Resistance and Ultimate Deformability of Structure Acted by Well Defined Repeated Load, IABSE, Lisbon, Portugal, 15–22.
Nagae, T., et al. (2012). “Test results of four-story reinforced concrete and post-tensioned concrete buildings: The 2010 E-Defense shaking table test.” Proc., 15th World Conf. on Earthquake Engineering, Lisbon, Portugal.
OpenSees [Computer software]. Univ. of California, Berkeley, CA.
Orakcal, K., Massone, L. M., and Wallace, J. W. (2006). “Analytical modeling of reinforced concrete walls for predicting flexural and coupled-shear-flexural responses.”, Univ. of California, Berkeley, CA.
Pampanin, S., Priestley, M. J. N., and Sritharan, S. (2001). “Analytical modeling of the seismic behavior of precast concrete frames designed with ductile connections.” J. Earthquake Eng., 5(3), 329–367.
Park, R., Priestley, M. J. N., and Gill, W. D. (1982). “Ductility of square-confined concrete columns.” J. Struct. Div., 108(4), 929–950.
PEER (Pacific Earthquake Engineering Research Center). (2012). “PEER ground motion database.” 〈http://peer.berkeley.edu/peer_ground_motion_database/〉 (Jun. 10, 2012).
Pennucci, D., Calvi, G. M., and Sullivan, T. J. (2009). “Displacement-based design of precast walls with additional dampers.” J. Earthquake Eng., 13(S1), 40–65.
Perez, F. J., Sause, R., and Pessiki, S. (2007). “Analytical and experimental lateral load behavior of unbonded posttensioned precast concrete walls.” J. Struct. Eng., 1531–1540.
Priestley, M. J. N. (1991). “Overview of PRESSS research program.” PCI J., 36(4), 50–57.
Priestley, M. J. N., Calvi, G. M., and Kowalsky, M. J. (2007). Displacement-based seismic design of structures, IUSS Press, Pavia, Italy.
Priestley, M. J. N., Sritharan, S., Conley, J. R., and Pampanin, S. (1999). “Preliminary results and conclusions from the PRESSS five-story precast concrete test building.” PCI J., 44(6), 42–67.
Rahman, M. A., and Sritharan, S. (2007). “Performance-based seismic evaluation of two five-story precast concrete hybrid frame buildings.” J. Struct. Eng., 1489–1500.
Restrepo, J., and Rahman, A. (2007). “Seismic performance of self-centering structural walls incorporating energy dissipators.” J. Struct. Eng., 1560–1570.
Ryu, D., Wijeyewickrema, A. C., ElGawady, M. A., and Madurapperuma, M. A. K. M. (2014). “Effects of tendon spacing on in-plane behavior of posttensioned masonry walls.” J. Struct. Eng., 04013096.
Smith, B. J., and Kurama, Y. (2012). “Seismic design guidelines for special precast precast concrete shear walls.”, Univ. of Notre Dame, South Bend, IN.
Smith, B. J., Kurama, Y., and McGinnis, M. J. (2011). “Design and measured behavior of a precast precast concrete wall specimen for seismic regions.” J. Struct. Eng., 1052–1062.
Smith, B. J., Kurama, Y., and McGinnis, M. J. (2013). “Behavior of precast concrete shear walls for seismic regions: comparison of hybrid and emulative specimens.” J. Struct. Eng., 1917–1927.
Thomsen, J., and Wallace, J. W. (1995). “Displacement-based design of RC structural walls: an experimental investigation of walls with rectangular and T-shaped cross-sections.”, Dept. of Civil and Environmental Engineering, Clarkson Univ., Potsdam, NY.
Tuna, Z., Gavridou, S., Wallace, J. W., Nagae, T., and Matsumori, T. (2012). “2010 E-Defense four-story reinforced concrete and post-tensioned buildings—Preliminary comparative study of experimental and analytical results.” Proc., 15th World Conf. on Earthquake Engineering, Lisbon, Portugal.
Vulcano, A., Bertero, V. V., and Colotti, V. (1988). “Analytical modeling of RC structural walls.” Proc., 9th World Conf. on Earthquake Engineering, Vol. 6, Tokyo-Kyoto, Japan, 41–46.
Wallace, J. W. (1992). “BIAX: Revision 1-computer program for the analysis of reinforced concrete and reinforced masonry sections.”, Structural Engineering, Mechanics, and Materials, Clarkson Univ., Potsdam, NY.
Wiebe, L., and Christopoulos, C. (2009). “Mitigation of higher mode effects in base-rocking systems by using multiple rocking sections.” J. Earthquake Eng., 13(S1), 83–108.
Yassin, M. H. M. (1994). “Nonlinear analysis of prestressed concrete structures under monotonic and cyclic loads.” Ph.D. dissertation, Univ. of California, Berkeley, CA.
Information & Authors
Information
Published In
Copyright
© 2016 American Society of Civil Engineers.
History
Received: Jan 2, 2015
Accepted: Nov 3, 2015
Published online: Jan 25, 2016
Published in print: Jun 1, 2016
Discussion open until: Jun 25, 2016
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.