Multiple Tuned Liquid Dampers for Efficient and Robust Structural Control
Publication: Journal of Structural Engineering
Volume 141, Issue 12
Abstract
In traditional tuned liquid damper (TLD) installations, TLD tank(s) are tuned to a single optimal frequency as determined by well-known dynamic vibration absorber theory. A multiple tuned liquid damper (MTLD) is created when the sloshing frequencies are distributed over a range near the structural frequency. In this paper, an equivalent mechanical model for a structure–MTLD system is developed. A third-order nonlinear multimodal model is employed to assess nonlinear fluid affects and serve as independent model verification. To the authors’ knowledge, this is the first time the nonlinear energy dissipation associated with damping screens and the nonlinear coupling amongst sloshing modes has been considered for MTLD systems. MTLD systems consisting of one (traditional TLD), two, and three tanks are used to reduce the resonant response of a single degree of freedom structure. The MTLD provides structural control that is superior to a traditional TLD. The MTLD is less sensitive to the structural excitation amplitude, which enables the device performance to be maintained at low amplitude excitations associated with common wind events. The MTLD is also shown to be more robust to changes to the structure’s natural frequency than the traditional TLD. Since many TLD installations require multiple tanks to satisfy space restrictions, the findings of this paper are highly relevant to structural engineering. This paper shows that by slightly altering the fluid depth of each tank, improved structural control performance can be achieved at little additional cost.
Get full access to this article
View all available purchase options and get full access to this article.
References
Ashasi-Sorkhabi, A., Kristie, J., and Mercan, O. (2014). “Investigations of the use of multiple tuned liquid dampers in vibration control.” Proc., Structures Congress, ASCE, Reston, VA, 1185–1196.
Caughey, T. K. (1963). “Equivalent linearization techniques.” J. Acoust. Soc. Am., 35(11), 1706–1711.
Faltinsen, O. M., Rognebakke, O. F., Lukovsky, I. A., and Timokha, A. N. (2000). “Multidimensional modal analysis of nonlinear sloshing in a rectangular tank with finite water depth.” J. Fluid Mech., 407, 201–234.
Fujino, Y., and Sun, L. M. (1993). “Vibration control by multiple tuned liquid dampers (MTLDs).” J. Struct. Eng., 3482–3502.
Igusa, T., and Xu, K. (1994). “Vibration control using multiple tuned mass dampers.” J. Sound Vib., 175(4), 491–503.
Kareem, A., and Kline, S. (1995). “Performance of multiple mass dampers under random loading.” J. Struct. Eng., 348–361.
Kim, Y., You, K., Ko, N., and Yoon, S. (2006). “Use of TLD and MTLD for control of wind-induced vibration of tall buildings.” J. Mech. Sci. Technol., 20(9), 1346–1354.
Li, C., and Liu, Y. (2002). “Further characteristics of multiple tuned mass dampers.” J. Struct. Eng., 1362–1365.
Love, J. S., and Haskett, T. C. (2014). “Using multiple tuned sloshing dampers (MTSDs) with distributed tuning for improved motion control of buildings.” Proc., 6th World Conf. on Structural Control and Monitoring, International Association for Structural Control and Monitoring, Los Angeles.
Love, J. S., and Tait, M. J. (2010). “Nonlinear simulation of a tuned liquid damper with damping screens using a modal expansion technique.” J. Fluids Struct., 26(7–8), 1058–1077.
Roberts, J. B., and Spanos, P. D. (1999). Random vibration and statistical linearization, Wiley, New York.
Robinson, J. K., Gamble, S. L., and Myslimaj, B. M. (2007). “Supplemental damping and using tuned sloshing dampers.” Struct. Mag., 14–18.
Soong, T. T., and Dargush, G. F. (1997). Passive energy dissipation systems in structural engineering, Wiley, Toronto.
Sun, L. M., Fujino, Y., Pacheco, B. M., and Isobe, M. (1989). “Nonlinear waves and dynamic pressure in rectangular tuned liquid damper (TLD)—Simulation and experimental verification.” JSCE Struct. Eng./Earthquake Eng., 6(2), 251s–262s.
Tait, M. J. (2008). “Modelling and preliminary design of a structure-TLD system.” Eng. Struct., 30(10), 2644–2655.
Tait, M. J., El Damatty, A. A., Isyumov, N., and Siddique, M. R. (2005). “Numerical flow models to simulate tuned liquid dampers (TLD) with slat screens.” J. Fluids Struct., 20(8), 1007–1023.
Vickery, B. J., and Davenport, A. G. (1972). “An investigation of the behaviour in wind of the proposed Centrepoint tower.”, BLWT Laboratory, London, ON, Canada.
Warburton, G. B. (1982). “Optimum absorber parameters for various combinations of response and excitation parameters.” Earthquake Eng. Struct. Dyn., 10(3), 381–401.
Xu, K., and Igusa, T. (1992). “Dynamic characteristics of multiple substructures with closely spaced frequencies.” Earthquake Eng. Struct. Dyn., 21(12), 1059–1070.
Information & Authors
Information
Published In
Copyright
© 2015 American Society of Civil Engineers.
History
Received: Sep 14, 2013
Accepted: Jan 26, 2015
Published online: Mar 11, 2015
Discussion open until: Aug 11, 2015
Published in print: Dec 1, 2015
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.