Effect of Active versus Passive Confinement on Seismic Response of Wide RC Columns with Lap Splices
Publication: Journal of Structural Engineering
Volume 141, Issue 9
Abstract
The results of an experimental study on seismic bond strengthening of spliced reinforcement in wide RC columns using external confinement are presented. Two types of confinement techniques were evaluated and compared, as follows: (1) a combination of external carbon fiber-reinforced polymer (CFRP) jacket and CFRP anchors, and (2) active confinement by means of pretensioned steel anchor rods. The effectiveness of the different strengthening techniques was evaluated by comparing with test results of companion as-built columns, and earthquake-designed columns which were detailed in accordance with the seismic provisions of a national building code. The columns were subjected to a quasi-static cyclic loading, simulating regions of high seismic hazard. In addition to the type of the strengthening system used, the test variables included area and diameter of the column longitudinal reinforcement. The as-built columns suffered bond and load degradation immediately after yielding of the spliced reinforcement. The actively confined specimens developed considerably larger lateral load, drift, and energy dissipation capacities than the as-built specimens, and performed better than the specimens strengthened using a combination of CFRP jacket and CFRP anchors, and even slightly better than the earthquake-designed specimens. A simple approach is presented for designing the strengthening systems required for effective bond strengthening.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers acknowledge the financial support provided by the Lebanese National Council for Scientific Research (LNCSR) under Grant No. 102622-21372. The writers are most grateful for that support and to the Faculty of Engineering and Architecture at the American University of Beirut (AUB) for providing the test facilities.
References
Aboutaha, R. S., Engelhardt, M. D., Jirsa, J. O., and Kreger, M. E. (1999). “Experimental investigation of seismic repair of lap splice failures in damaged concrete columns.” ACI Struct. J., 96(2), 297–306.
American Concrete Institute (ACI). (1977). “Building code requirements for reinforced concrete.”, Detroit, MI.
American Concrete Institute (ACI). (2011). “Building code requirements for reinforced concrete and commentary.”, Farmington Hills, MI.
Bournas, D. A., and Triantafillou, T. C. (2011). “Bond strength of lap-spliced bars in concrete confined with composite jackets.” J. Compos. Constr., 156–167.
Darwin, D., Lutz, L. A., and Zuo, J. (2005). “Recommended provisions and commentary on development and lap splice lengths for deformed reinforcing bars in tension.” ACI Struct. J., 102(6), 892–900.
El Gawady, M., Endeshaw, M., McLean, D., and Sack, R. (2010). “Retrofitting of rectangular columns with deficient lap splices.” J. Compos. Constr., 22–35.
Eligehausen, R., Popov, E. P., and Bertero, V. V. (1983). “Local bond stress-slip relationships of deformed bars under generalized excitations.”, Univ. of California, Berkeley, CA.
El Souri, A. M., and Harajli, M. H. (2011). “Seismic repair and strengthening of lap splices in RC columns: Carbon fiber-reinforced polymer versus steel confinement.” J. Compos. Constr., 721–731.
Ghosh, K. K., and Sheikh, S. A. (2007). “Seismic upgrade with carbon fiber-reinforced polymer of columns containing lap-spliced reinforcing bars.” ACI Struct. J., 104(2), 227–236.
Hantouche, E. G., and Harajli, M. H. (2013). “Seismic FRP bond strengthening of the critical splice region in wide reinforced concrete columns.” Proc., Structures Congress, ASCE, Reston, VA, 2068–2079.
Harajli, M. H. (2008). “Seismic behavior of RC columns with bond-critical regions: Criteria for bond strengthening using external FRP jackets.” J. Compos. Constr., 69–79.
Harajli, M. H., and Dagher, F. (2008). “Seismic strengthening of bond-critical regions in reinforced concrete columns using fiber-reinforced polymer wraps.” ACI Struct. J., 105(1), 68–77.
Harries, K. A., Ricles, J. R., Pessiki, S., and Sause, R. (2006). “Seismic retrofit of lap splices in nonductile square columns using carbon fiber-reinforced jackets.” ACI Struct. J., 103(6), 874–884.
Hawkins, N. M., Gamble, W. L., Shkurti, F. J., and Lin, Y. (2000). “Seismic strengthening of inadequate length splices.” Proc., World Conf. on Earthquake Engineering.
Kim, I., Jirsa, J. O., and Bayrak, O. (2011). “Use of carbon fiber-reinforced polymer anchors to repair and strengthen lap splices of reinforced concrete columns.” ACI Struct. J., 105(5), 630–640.
Mitchell, D., Sexsmith, R., and Tinawi, R. (1994). “Seismic retrofitting techniques for bridges: A state-of-the-art report.” Can. J. Civ. Eng., 21(5), 823–835.
Orangun, C. O., Jirsa, J. O., and Breen, J. E. (1975). “Strength of anchored bars: A reevaluation of test data on development length and splices.”, Center for Highway Research, Univ. of Texas, Austin, TX.
Priestley, M. J. N., and Park, R. (1987). “Strength and ductility of concrete bridge columns under seismic loading.” ACI Struct. J., 84(1), 61–76.
Priestley, M. J. N., Seible, F., and Calvi, G. M. (1996). Seismic design and retrofit of bridges, Wiley, New York.
Seible, F., Priestly, M. J. N., Hegemier, G. A., and Innamorato, D. (1997). “Seismic retrofit of RC columns with continuous carbon fiber jackets.” J. Compos. Constr., 52–62.
Untrauer, R. E., and Henry, R. L. (1965). “Influence of normal pressure on bond strength.” ACI J., 62(5), 572–585.
Xu, F., Wu, Z., Zheng, J., Hu, Y., and Li, Q. (2014). “Bond behavior of plain bars in concrete under complex lateral pressures.” ACI Struct. J., 111(1), 15–25.
Information & Authors
Information
Published In
Copyright
© 2014 American Society of Civil Engineers.
History
Received: Feb 19, 2014
Accepted: Sep 25, 2014
Published online: Oct 20, 2014
Discussion open until: Mar 20, 2015
Published in print: Sep 1, 2015
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.