Precast spandrel beams are often used on the perimeter of precast buildings to support the precast floor units. These elements are typically not considered part of the lateral force resisting system. However, the presence of the spandrel beams in the floor system may modify the strength, stiffness, and deformation capacity of the precast floor diaphragm. The nature of this response is highly dependent on the characteristics of the details connecting the spandrel to the precast floor system. These details are often welded connections used primarily for erection stability and designed without diaphragm action in mind. With emerging design methodologies for precast diaphragms requiring better-defined performance, the impact of the spandrel beams must be accounted for. Accordingly, analytical research is presented here that examines the effect of spandrel-beam-connecting details on the global characteristics and local demands of a flexure-controlled precast floor diaphragm. Design recommendations are provided.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research was supported by the National Science Foundation (NSF) under Grant NSFCMS-0324522, the Precast/Prestressed Concrete Institute (PCI), and the Charles Pankow Foundation (CPF). The authors are grateful for this support.
Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the National Science Foundation.
References
American Concrete Institute (ACI). (2008). “Building code requirements for structural concrete and commentary.” ACI 318-08, Farmington Hills, MI.
Anderson, Neal S., and Meinheit, Donald F. (2000). “Design criteria for headed stud groups in shear: Part 1—Steel capacity and back edge effects.” PCI J., 45(5), 46–75.
ANSYS version 8.0. (2004). Elements and theory reference, 9th Ed., ANSYS Inc., Canonsburg, PA.
American Society of Civil Engineers/Structural Engineering Institute (ASCE/SEI). (2010). “Minimum design loads for buildings and other structures.” ASCE/SEI 7-10, Reston, VA.
Building Seismic Safety Council, Committee TS-4. (2009). “Seismic design methodology for precast concrete floor diaphragms.” Part III, 2009 NEHRP Recommended Seismic Provisions, Federal Emergency Management Agency, Washington, DC.
Cao, L., Naito, C., and Sause, R. (2006). “Phase 1 experimental evaluation of diaphragm connections: program overview.” Rep. DSDM LU Group, Lehigh University, Bethlehem, PA.
Farrow, K. T., and Fleischman, R. B. (2003). “Effect of dimension and detail on the capacity of precast concrete parking structure diaphragms.” PCI J., 48(5), 46–61.
Fleischman, R. B., and Wan, G. (2007). “Appropriate overstrength of shear reinforcement in precast concrete diaphragms.” J. Struct. Eng., 133(11), 1616–1626.
International Building Code (IBC). (2009). 2009 International building code, International Code Council, Inc., Falls Church, VA.
Iverson, J. K., and Hawkins, N. M. (1994). “Performance of precast/prestressed concrete building structures during Northridge earthquake.” PCI J., 39(2), 38–55.
Lee, H. J., and Kuchma, D. A. (2008). “Seismic response of parking structures with precast concrete diaphragms.” PCI J., 53(2), 71–94.
Naito, C., Peter, W., and Cao, L. (2006). “Development of a seismic design methodology for precast diaphragms—Phase 1 summary report.” ATLSS Rep. No.06-01, ATLSS Center, Lehigh University, PA.
Precast/Prestressed Concrete Institute (PCI). (2010). PCI design handbook—Precast and prestressed concrete, 7th Ed., PCI, Chicago.
Pincheira, J. A., Oliva, M. G., and Kusumo-Rahardjo, F. I. (1998). “Tests on double-tee flange connectors subjected to monotonic and cyclic loading.” PCI J., 43(3), 82–96.
Rodriguez, M., Restrepo, J., and Carr, A. J. (2002). “Earthquake induced floor horizontal accelerations in buildings.” J. Earthquake Eng. Struct. Dyn., 31(3), 693–718.
Schoettler, M. J., Belleri, A., Zhang, D., Restrepo, J., and Fleischman, R. B. (2009). “Preliminary results of the shake-table testing for development of a diaphragm seismic design methodology.” PCI J., 54(1), 100–124.
Shaikh, A. F., and Feile, E. (2004). “Load testing of a precast concrete double-tee flange connector.” PCI J., 49(3), 84–94.
Structural Engineers Association of California. (1999). “Recommended lateral force requirements and commentary (SEAOC Blue Book).” 7th Ed., Sacramento, CA.
Wood, S. L., Stanton, J. F., and Hawkins, N. M. (2000). “New seismic design provisions for diaphragms in precast concrete parking structures.” PCI J., 45(1), 50–65.
Zhang, D. (2010). “Examination of precast concrete diaphragm seismic response by three-dimensional nonlinear dynamic transient analyses.” Ph.D. dissertation, University of Arizona, Tucson.
Information & Authors
Information
Published In
Copyright
© 2012 American Society of Civil Engineers.
History
Received: Sep 5, 2008
Accepted: Apr 18, 2011
Published online: Apr 20, 2011
Published in print: Feb 1, 2012
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.