In-Plane Lateral Cyclic Behavior of Insulated Concrete Form Grid Walls
Publication: Journal of Structural Engineering
Volume 137, Issue 10
Abstract
The in-plane lateral behavior of insulated concrete form grid walls consisting of prefabricated stay-in-place form blocks made of recycled expanded polystyrene and evenly spaced horizontal and vertical reinforced concrete cores was experimentally investigated. Incrementally increasing reversed cyclic drifts were imposed on sets of full-scale walls of two different aspect ratios and on two different vertical loading conditions. The results of the 13 experiments indicated that a consistent wall failure mode stemmed from fracture of the individual vertical cores. Additional vertical load was found to increase the strength and effective stiffness of the walls, but the effect on drift capacity and ductility depended on the wall aspect ratio. The residual stiffness and energy dissipation severely degraded within cycles of 1% drift for all aspect geometries and loading conditions. The stay-in-place form blocks had a significant positive influence on the behavior despite the material’s relatively low strength.
Get full access to this article
View all available purchase options and get full access to this article.
References
American Concrete Institute (ACI). (2001). “Commentary on acceptance criteria for moment frames based on structural testing.” ACI T1-1R-01, Skokie, IL.
American Concrete Institute (ACI). (2008a). “Building code requirements for structural concrete and commentary.” ACI 318-08, Skokie, IL.
American Concrete Institute (ACI). (2008b). “Acceptance criteria for special unbonded post-tensioned precast structural walls based on validation testing and commentary.” ACI ITG-5.1-07, Skokie, IL.
ASTM. (2009a). “Standard specification for deformed and plain carbon-steel bars for concrete reinforcement.” A615, West Conshohocken, PA.
ASTM. (2009b). “Standard specification for low-alloy steel deformed and plain bars for concrete reinforcement.” A706, West Conshohocken, PA.
ASTM. (2009c). “Standard test method for compressive strength of cylindrical concrete specimens.” C39/C39M-09, West Conshohocken, PA.
ASTM. (2009d). “Standard test methods and definitions for mechanical testing of steel products.” A370-09ae1, West Conshohocken, PA.
Mehrabi, A. B. (2000). “In-plane lateral load resistance of wall panels in residential buildings.” R&D Serial No. 2403, Portland Cement Association, Skokie, IL.
National Association of Home Builders (NAHB). (1997). “Insulating concrete forms for residential construction—Demonstration homes.” Upper Marlboro, MD.
National Association of Home Builders (NAHB). (2001). “In-plane shear resistance of insulating concrete form walls.” Upper Marlboro, MD.
National Association of Home Builders (NAHB). (2002). Prescriptive method for insulating concrete forms in residential construction, 2nd Ed., Upper Marlboro, MD.
Portland Cement Association (PCA). (2007). Prescriptive design of exterior concrete walls for one- and two-family dwellings, PCA 100-2007, Skokie, IL.
VanderWerf, P. A. (1997). Insulating concrete forms for residential design and construction, McGraw-Hill, NY.
Yland, C. V. (2000). “Experimental and analytical studies of the structural performance of innovative structural grid walls.” Ph.D. dissertation, Univ. of CA, Irvine, CA.
Information & Authors
Information
Published In
Copyright
© 2011 American Society of Civil Engineers.
History
Received: Feb 17, 2010
Accepted: Nov 9, 2010
Published online: Dec 3, 2010
Published in print: Oct 1, 2011
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.