Critical Parameters and Configurations Affecting the Analysis and Design of Guyed Transmission Towers under Downburst Loading
Publication: Practice Periodical on Structural Design and Construction
Volume 22, Issue 1
Abstract
In past years, many electrical transmission lines have failed during downbursts. This study is part of a research program aimed at understanding the behavior of transmission lines under localized winds. Most downbursts need to be modeled using computational fluid dynamic (CFD) models; this is not an easy task for engineers in general. This paper focuses on replacing the complicated velocities obtained from CFD models with simplified loads that represent, in a more practical fashion, the critical downburst configurations causing the guyed transmission towers to fail. Different options are considered in terms of the location and nature of the design velocity associated with different configurations. The profile of the horizontal velocity is developed. A practical simplified load corresponding to each of the critical configurations is developed. Detailed steps of the conductors’ reaction calculations are provided. A simplified procedure is developed for designing downburst-loaded guyed transmission towers.
Get full access to this article
View all available purchase options and get full access to this article.
References
ASCE. (2010). “Guidelines for electrical transmission line structural loading.” ASCE manuals and reports on engineering practice, No. 74, Reston, VA.
Darwish, M. M., El Damatty, A. A., and Hangan, H. M. (2010). “Dynamic characteristics of transmission line conductors and behaviour under turbulent downburst loading.” Wind Struct., 13(4), 327–346.
Dotzek, N., and Friedrich, K. (2009). “Downburst-producing thunderstorms in southern Germany: Radar analysis and predictability.” Atmos. Res., 93(1–3), 457–473.
Fujita, T. (1990). “Downbursts: Meteorological features and wind field characteristics.” J. Wind Eng. Ind. Aerodyn., 36(1), 75–86.
Gast, K. D. (2003). “A comparison of extreme wind events as sampled in the 2002 Thunderstorm Outflow Experiment.” Master’s thesis, Texas Tech Univ., Lubbock, TX.
Hangan, H., and Kim, J. D. (2004). “Numerical simulation of downbursts.” ASCE Structural Congress, ASCE, Reston, VA, 1657–1664.
Hangan, H., and Kim, J. D. (2007). “Numerical simulations of impinging jets with application to downbursts.” J. Wind Eng. Ind. Aerodyn., 95(4), 279–298.
Holmes, J., Hangan, H. M., Schroeder, J., Letchford, L., and Orwig, K. (2008). “A forensic study of the Lubbock-Reese downdraft of 2002.” Wind Struct., 11(2), 137–152.
Kaňák, J., Benko, M., Simon, A., and Sokol, A. (2007). “Case study of the 9 May 2003 windstorm in south-western Slovakia.” Atmos. Res., 83(2–4), 162–175.
Kwon, D., and Kareem, A. (2009). “Gust-front factor: New framework for wind load effects on structures.” J. Struct. Eng., 717–732.
Manitoba Hydro Transmission and Civil Design Department. (1999). “Bipole 1 & 2 HVDC transmission line wind storm failure on September 5, 1996—Review of emergency response, restoration and design of these lines.” 98-L1/1-37010-06000, 54, Manitoba Hydro, Inc., Winnipeg, Manitoba, Canada.
Orwig, K., and Schroeder, J. (2007). “Near-surface wind characteristics of extreme thunderstorm outflows.” J. Wind Eng. Ind. Aerodyn., 95(7), 565–584.
Savory, E., Parke, G., Zeinoddini, M., Toy, N., and Disney, P. (2001). “Modelling of tornado and microburst-induced wind loading and failure of a lattice transmission tower.” Eng. Struct., 23(4), 365–375.
Shehata, A. Y., and El Damatty, A. A. (2007). “Behaviour of guyed transmission line structures under downburst wind loading.” Wind Struct., 10(3), 249–268.
Shehata, A. Y., and El Damatty, A. A. (2008). “Failure analysis of a transmission tower during a microburst.” Wind Struct., 11(3), 193–208.
Shehata, A., El Damatty, A., and Savory, E. (2005). “Finite element modeling of transmission line under downburst wind loading.” Finite Elem. Anal. Des., 42(1), 71–89.
Shehata, A. Y., Nassef, A. O., and El Damatty, A. A. (2008). “A coupled finite element-optimization technique to determine critical microburst parameters for transmission towers.” Finite Elem. Anal. Des., 45(1), 1–12.
Xie, Q., Zhang, Y., and Li, J. (2006). “Investigation on tower collapses of 500 kV Renshang 5237 transmission line caused by downburst 2.” Power Syst. Technol., 30(10), 59–63.
Information & Authors
Information
Published In
Copyright
© 2016 American Society of Civil Engineers.
History
Received: Jan 22, 2016
Accepted: Jul 20, 2016
Published online: Aug 30, 2016
Discussion open until: Jan 30, 2017
Published in print: Feb 1, 2017
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.