Corrosion Durability of Reinforcing Steel in Cracked High-Performance Fiber-Reinforced Cementitious Composite Beams
Publication: Journal of Materials in Civil Engineering
Volume 27, Issue 8
Abstract
This paper reports test results on the corrosion durability of reinforcing steel in three series of precracked beams of ordinary mortar; a high-performance fiber-reinforced cementitious composite (HPFRCC) containing polyethylene (PE) fibers, referred as mono HPFRCC; and hybrid combinations of steel cord (SC) and PE fibers, referred as hybrid HPFRCC. In each series three precracked beams with a maximum crack width of 0.1–0.5 mm were tested. All beams were subjected to an accelerated corrosion regime consisting of applying constant 3-V DC potential across rebar (anode) and cathode and cyclic wetting and drying cycles. The durability performance of the specimens was examined through regular monitoring of corrosion current—hence, the calculated steel loss, the corrosion-induced damage measured by the longitudinal crack width and through visual inspection. At the end of the corrosion tests, the reinforcing bars in all specimens were exposed to observe the corrosion depth, corroded area, actual amount of steel loss, and residual tensile strength. Results showed that the hybrid HPFRCC specimens exhibited better performance than did the mortar and mono HPFRCC specimens. Relationships of maximum crack width with actual steel loss, maximum corrosion depth, and residual tensile strength were observed in mono and hybrid HPFRCC beams. However, no correlation between maximum crack width and corroded area was observed in all series. The relationship of maximum corrosion depth and actual amount of corrosion in the hybrid and mono HPFRCC series was also observed in this study.
Get full access to this article
View all available purchase options and get full access to this article.
References
Ahmed, S. F. U., and Mihashi, H. (2010). “Corrosion durability of strain hardening fibre-reinforced cementitious composites.” Aust. J. Civ. Eng., 8(1), 27–39.
Arya, C., and Ofori-darka, F. K. (1996). “Influence of crack frequency on reinforcement corrosion in concrete.” Cem. Concr. Res., 26(3), 345–353.
Auyeung, Y., Balaguru, P., and Chung, L. (2000). “Bond behaviour of corroded reinforcement bars.” ACI Mater. J., 97(2), 214–220.
Bentur, A., Diamond, S., and Berke, N. (1997). Steel corrosion in concrete, fundamental and civil engineering practice, E & FN Spon, London, 41–43.
Granju, J. L., and Balouch, S. U. (2005). “Corrosion of steel fibre reinforced concrete from the cracks.” Cem. Concr. Res., 35(3), 572–577.
Homma, D., Mihashi, H., and Nishiwaki, T. (2009). “Self-healing capability of fiber reinforced cementitious composites.” J. Adv. Concr. Technol., 7(2), 217–228.
Japan Concrete Institute (JCI). (2004). Standard collection of JCI, Tokyo, Japan, 91–105.
Karasawa, T., Masuda, Y., Kohno, M., and Takeuchi, H. (2004). “Influence that crack exerts on corrosion of reinforced concrete.” Proc. Japan Concr. Inst., 26(1), 873–878.
Li, V. C. (2003). “On engineered cementitious composites: A review of the materials and its applications.” J. Adv. Concr. Technol., 1(3), 215–230.
Maaddawy, T. A. E., and Soudki, K. A. (2003). “Effectiveness of impressed current technique to simulate corrosion of steel reinforcement in concrete.” J. Mater. Civ. Eng., 41–47.
Maalej, M., Ahmed, S. F. U., and Paramasivam, P. (2003). “Corrosion durability and structural response of functionally graded concrete beams.” J. Adv. Concr. Technol., 1(3), 307–316.
Mihashi, H., Ahmed, S. F. U., and Kobayakawa, A. (2011). “Corrosion of reinforcing steel in fibre reinforced cementitious composites.” J. Adv. Concr. Technol., 9(2), 159–167.
Miyazato, S., and Hiraishi, Y. (2005). “Transport properties and steel corrosion in ductile fibre reinforced cement composites.” Proc., ICF.
Mohammed, T. U., Otsuki, N., Hisada, M., and Shibata, T. (2001). “Effect of crack width and bar types on corrosion of steel in concrete.” J. Mater. Civ. Eng., 194–201.
Okada, K., and Miyagawa, T. (1980). “Chloride corrosion of reinforcing steel in cracked concrete.” ACI SP, 65, 237–254.
Otieno, M. B., Alexander, M. G., and Beushausen, H. D. (2009). “Corrosion propagation in cracked and un-cracked concrete.” Proc., Concrete Repair, Rehabilitation and Retrofitting II, M. G. Alexander, et al., eds., Taylor and Francis Group, London.
Reinhardt, H. W., and Naaman, A. E. (1992). High performance fibre reinforced cementitious composites, E & FN Spon, London, 565.
Rossi, P. (2000). “Ultra high performance fibre reinforced concrete: An overview.” Proc., 5th Int. RILEM Symp., P. Rossi and G. Chanvillard, eds., 87–100.
Sahamaran, M., Li, V. C., and Andrade, C. (2008). “Corrosion resistance performance of steel reinforced engineered cementitious composites beams.” ACI Mater. J., 105(3), 243–250.
Sahmaran, M., and Yaman, I. O. (2008). “Influence of transverse crack width on reinforcement corrosion initiation and propagation in mortar beams.” Can. J. Civ. Eng., 35(3), 236–245.
Sangoju, B., Gettu, R., Baharatkumar, B. H., and Neelamegam, M. (2011). “Chloride induced corrosion of steel in cracked OPC and PPC concretes: Experimental study.” J. Mater. Civ. Eng., 1057–1066.
Schiebl, P., and Raupach, M. (1997). “Laboratory studies and calculations on the influence of crack width on chloride induced corrosion of steel in concrete.” ACI Mater. J., 94(1), 56–62.
Tsukamoto, M., and Wörner, J.-D. (1991). “Permeability of cracked fibre–reinforced concrete.” Darmstadt Concr. Annu. J. Concr. Concr. Struct., 6, 123–135.
Vida, T., Castel, A., and Francois, R. (2004). “Analyzing crack width to predict corrosion in reinforced concrete.” Cem. Concr. Res., 34(1), 165–174.
Information & Authors
Information
Published In
Copyright
© 2014 American Society of Civil Engineers.
History
Received: Apr 1, 2014
Accepted: Sep 2, 2014
Published online: Oct 9, 2014
Discussion open until: Mar 9, 2015
Published in print: Aug 1, 2015
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.