Possible Role of Simple Ionic Solutions on the Water Transport Kinetics and Mechanical Properties of Hydrated Lime Mortars
Publication: Journal of Materials in Civil Engineering
Volume 27, Issue 3
Abstract
The CL90 mortar (i.e., the nonhydraulic lime mortar) is dramatically more water retaining than any of the hydraulic mortars. This paper investigates the possible role of simple ionic solutions used as mix water on the water transport kinetics and mechanical properties of hydrated lime mortars. The results show that the addition of sulphate solutions as mix water does not only improve the transfer sorptivity and time to dewater, but also consistency and setting time of hydrated lime mortars. Compressive strength of hydrated lime mortars is significantly increased when potassium sulphate is used as mix water solution, and this is supported with microstructural analysis. The parameters studied in this paper form the main barriers to the use of hydrated lime mortars in construction practice; therefore, the use of hydrated lime mortars may be encouraged if the simple ionic solutions as mix water can improve the fresh and hardened properties of these mortars.
Get full access to this article
View all available purchase options and get full access to this article.
References
ASTM. (2011). “Standard specification for hydrated lime for masonry purposes.” ASTM C207 – 06, West Conshohocken, PA.
Ball, R. J., and Allen, G. C. (2010). “The measurement of water transport in porous materials using impedance spectroscopy.” J. Phys. Appl. Phys., 43(10), 105503.
Ball, R. J., Allen, G. C., Carter, M. A., Wilson, M. A., Ince, C., and El-Turki, A. (2012). “The application of electrical resistance measurements to water transport in lime-masonry systems.” Appl. Phys. A Mater. Sci. Process., 106(3), 669–677.
Bentur, A. (2002). “Cementitious materials—Nine millennia and a new century: Past present and future.” J. Mater. Civ. Eng., 2–22.
British Standards Institution (BSI). (1999). “Methods of test for mortar for masonry. Determination of consistence of fresh mortar (by flow table).”, Milton Keynes, England.
British Standards Institution (BSI). (2005). “+A1: (2008) Methods of testing cement. Determination of setting times and soundness.”, Milton Keynes, England.
British Standards Institution (BSI). (2010). “Building lime. Test methods.”, Milton Keynes, England.
Carter, M. A., Green, K. M., Wilson, M. A., and Hoff, W. D. (2003). “Measurement of the water retentivity of cement mortars.” Adv. Cem. Res., 15(4), 155–159.
Cizer, O., Van Balen, K., Van Gemert, D., and Elsen, J. (2008). “Blended lime-cement mortars for conservation purposes: Microstructure and strength development.” 6th Int. Conf. Struc. Anal. Hist. Const., Vol. 1, Taylor & Francis, London, U.K., 525–532.
Collier, N. C., et al. (2007). “Theoretical development and validation of a sharp front model of the dewatering of a slurry by an absorbent substrate.” J. Phys. Appl. Phys., 40(13), 4049–4054.
El-Turki, A., Ball, R. J., and Allen, G. C. (2006). “Simulated aging of lime mortars—A mechanical property, structural and compositional study. Heritage.” Weathering and Conservation Conf., Taylor & Francis, London, U.K., 51–56.
El-Turki, A., Ball, R. J., Carter, M. A., Wilson, M. A., Ince, C., and Allen, G. C. (2010). “Effect of dewatering on the strength of lime and cement mortars.” J. Am. Ceram. Soc., 93(7), 2074–2081.
Green, K. M., Carter, M. A., Hoff, W. D., and Wilson, M. A. (1999). “The effect of lime and admixtures on the water-retaining properties of cement mortars.” Cem. Concr. Res., 29(11), 1743–1747.
Hall, C., and Hoff, W. D. (2002). Water transport in brick, stone and concrete, Taylor & Francis, London.
Ince, C. (2009). “The water transport kinetics in mortar-masonry systems.” Ph.D. thesis, School of Mechanical Aerospace and Civil Engineering, Univ. of Manchester, Manchester, U.K.
Ince, C., et al. (2010). “Analysis of the abstraction of water from freshly mixed jointing mortars in masonry construction.” Mater. Struct., 43(7), 985–992.
Ince, C., et al. (2011). “Factors affecting the water retaining characteristics of lime and cement mortars in the freshly-mixed state.” Mater. Struct., 44(2), 509–516.
Lanas, J., Pe’rez Bernal, J. L., Bello, M. A., and Alvarez Galindo, J. I. (2004). “Mechanical properties of natural hydraulic lime-based mortars.” Cem. Concr. Res., 34(12), 2191–2201.
Lothenbach, B., Winnefeld, F., Alder, C., Wieland, E., and Lunk, P. (2007). “Effect of temperature on the pore solution, microstructure and hydration products of portland cement pastes.” Cem. Concr. Res., 37(4), 483–491.
Malinowski, R., and Garfinkel, Y. (1991). “Prehistory of concrete.” Concr. Int., 13(3), 62–68.
Maurenbrecher, A. H. P. (2004). “Mortars for repair of traditional masonry.” Pract. Period. Struct. Des. Constr., 62–65.
Ronen, A., Bentur, A., and Soroka, I. (1991). “A plastered floor from the neolithic village Yiftahel (Israel).” Paleorient, 17(2), 149–155.
Information & Authors
Information
Published In
Copyright
© 2014 American Society of Civil Engineers.
History
Received: Oct 7, 2013
Accepted: Feb 5, 2014
Published online: Jul 16, 2014
Discussion open until: Dec 16, 2014
Published in print: Mar 1, 2015
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.