Abstract
Conventional methods of measuring carbonation and chloride ingress exist, but they are either inaccurate, expensive, or involve destructive testing. In seeking new solutions to this problem, the potential to use novel fiber-optic chemical sensors developed specifically for this application and designed to monitor chemical changes in cementitious materials, in situ and nondestructively, was explored in this study. Three types of fiber-optic sensors were thus constructed, tested, and evaluated, viz a temperature sensor, a pH sensor, and chloride sensors. The temperature sensor was based on the fluorescence decay of temperature-dependent materials, whereas the pH and chloride sensors were based on sol-gel technology, with pH and chloride sensitive indicators impregnated in the sol-gels. All the sensors were tested in situ, and subsequently, the temperature and the pH sensors were embedded in mortar and tested. It was found that both the temperature sensor and the pH sensor could function correctly for over 18 months after placement, but there was an issue with alignment of the sensor each time it was reconnected to the hardware. However, the laboratory tests showed that the chloride sensor was not reversible, and therefore further refinement was considered to be necessary before it could be used in situ in environments where the chloride content was known, from other measurements, to decrease. Research is ongoing to refine the sensor performance and expands the in situ testing program. The sensors themselves are inexpensive to fabricate, but the sensing hardware used in this work is costly because of its high versatility.
Get full access to this article
View all available purchase options and get full access to this article.
References
Alonso, C., Andrade, C., Castellote, M., and Castro, P. (2000). “Chloride threshold values to depassivate reinforcing bars embedded in a standardized OPC mortar.” Cem. Concr. Res., 30(7), 1047–1055.
Anson, M. (1988). “Early age strain and temperature measurements in concrete tank walls.” Mag. Concr. Res., 40(145), 216–226.
Cosentino, P., Grossman, B., Shieh, C., Doi, S., Xi, H., and Erbland, P. (1995). “Fibre optic chloride sensor development.” J. Geotech. Eng., 121(8), 610–617.
Glass, G., Wang, Y., and Buenfeld, N. (1996). “An investigation of experimental methods used to determine free and total chloride contents.” Cem. Concr. Res., 26(9), 1443–1449.
Grattan, S. (2009). “Development of fibre optic sensors for monitoring pH and reinforcement corrosion in concrete.” Ph.D. thesis, Queens Univ., Belfast, UK.
Harris, D. C. (1998). Quantitative chemical analysis, 5th Ed., W. H. Freeman and Co., New York.
Hecht, J. (2002). Understanding fibre optics, 4th Ed., Prentice Hall, Upper Saddle River, NJ.
King, E. J. (1959). Qualitative analysis and electrolytic solutions, Oliver and Boyd, New York.
Lau, K. (2003). “Fibre-optic sensors for smart composites for concrete applications.” Mag. Concr. Res., 55, (1), 19–34.
Maaskant, R. (1997). “Fiber-optic Bragg grating sensors for bridge monitoring.” Cem. Concr. Compos., 19(1), 21–33.
Srinivasan, R. (2000). “Embedded micro-sensor for monitoring pH in concrete structures.” SPIE 7th Int. Symp. on Smart Structures and Materials, Society of Photo-optical Instrumentation Engineers, Bellingham, WA, 40–44.
Stewart, M., and Mullard, J. (2010). Life-cycle cost optimisation of maintenance strategies for reinforced concrete structures in chloride environments, BCRI 10, Bridge and Concrete Research in Ireland, Cork, Ireland, 1–15.
Wolfbeis, O. (1991). Fibre optic chemical sensors and biosensors, Volume II, CRC Press, London.
Xie, W., Sun, T., Grattan, K. T. V., McPolin, D., Basheer, P. A. M., and Long, A. E. (2004). “Fibre optic chemical sensor systems for internal concrete conditioning monitoring.” Second European Workshop on Optical Fibre Sensors, Proc. SPIE 5502, Society of Photo-optical Instrumentation Engineers, Bellingham, WA, 334–337.
Zhao, W., Sun, T., Grattan, K., and Sun, W. (2003). “Nd-doped fluorescent fibre fire alarm system based on signal regression approaches.” 16th Int. Conf. on Optical Fibre Sensors, 176–179.
Information & Authors
Information
Published In
Copyright
© 2011 American Society of Civil Engineers.
History
Received: Jul 1, 2010
Accepted: Feb 7, 2011
Published online: Feb 10, 2011
Published in print: Aug 1, 2011
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.