Quantification of Flood Runoff Reduction Effect of Storage Facilities by the Decrease in CN
Publication: Journal of Hydrologic Engineering
Volume 18, Issue 6
Abstract
This study proposed a methodology for quantifying the flood runoff reduction effect of storage facilities by curve number (CN). The runoff hydrographs for various rainfall durations and return periods were derived using the modified rational method. The effect of runoff reduction due to the introduction of storage facilities was then quantified by CN. The result derived was summarized in a graph showing the decrease in CN as an effect of the runoff reduction with respect to the rainfall duration, return period, runoff coefficient of the catchment, and size of the storage facility. The runoff reduction effect of a storage facility was able to be easily and directly estimated using the derived graph. The result derived was also found to be well matched with the previous study for three different sites.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research was supported by a grant (NEMA-06-NH-03) from the Natural Hazard Mitigation Research Group, National Emergency Management Agency and the National Research Foundation of Korea (NRF) grant funded by the Korea government (MEST) (No. KRF-2008-313-D01083).
References
Akan, A. O. (2002). “Modified rational method for sizing infiltration structures.” Can. J. Civ. Eng., 29(4), 539–542.
Aron, G., and Kibler, D. F. (1990). “Pond sizing for rational formular hydrographs.” Water Resour. Bull., 26(2), 255–258.
Aron, G., and Kibler, D. F. (1990). “Pond sizing for rational formula hydrographs.” J. Am. Water Resour. Assoc., 26(2), 255–258.
Carter, T. L., and Rasmussen, T. C. (2006). “Hydrologic behavior of vegetated roof.” J. Am. Water Resour. Assoc., 42(5), 1261–1274.
Currey, L., and Akan, A. O. (1998). “Single outlet detention pond design and analysis equation.” Water Resour. Eng., 1, 796–801.
Federal Aviation Agency, Dept. of Transportation. (1970). “Advisory circular on airport drainage.”, Washington, DC, 80.
Hua, J., Liang, Z., and Yu, Z. (2003). “A modified rational formula for flood design in small basin.” J. Am. Water Resour. Assoc., 39(5), 1017–1025.
Kim, K. T. (2003). “A proposal for CN estimation using the detailed soil maps.” Mag. Kor. Water Resour. Assoc., 36(4), 45–53.
Kim, K., and Yoo, C. (2009). “Hydrological modeling and evaluation of rainwater harvesting facilities: Case study on several rainwater harvesting facilities in Korea.” J. Hydrol. Eng., 14(6), 545–561.
Kim, Y. R., Kim, J. Y., and Hwang, S. H. (2004). “Application of stormwater detention facilities for lacking capacity of sewers.” J. Kor. Soc. Water Wastewater, 18(3), 343–350.
Kim, R. H., Kim, Y. M., Kwon, K. H., Lee, S. H., and Lee, J. H. (2006). “Development of design methodology of rainwater utilization facilities in building complexes for sound water cycle.” Proc., KSWQ-KSWW Joint Spring Academic Conf., Korean Society of Water and Wastewater, 305–308.
Korea Institute of Construction Technology (KICT). (2004). “21st century frontier R&D program—Sustainable water resources research program: Technology for rainwater storage and utilization.” Gyeonggi-do, 435.
Korean Society of Water, and Wastewater (KSWW). (2005). “A research on operation, management and monitoring of rainwater utilization facilities.” Seoul, 144.
Lee, H. S. (2005). “A new comprehensive flood control plan.” Mag. Kor. Water Resour. Assoc., 38(4), 14–19.
McEnroe, B. M. (1992). “Preliminary sizing of detention reservoirs to reduce peak discharges.” J. Hydraul. Eng., 118(11), 1540–1549.
Ministry of Agriculture, and Forestry (MAF). (2003). “The development of rainwater utilizing system for domestic water at agricultural and fishing district.” Gyeonggi-do, 286.
Ministry of Construction, and Transportation (MOCT). (2000). “Maps for design rainfalls in South Korea, Report for the research and development of water resources management in 1999.” Seoul, 292.
National Institute for Disaster Prevention (NIDP). (1999). “Study on the storage and infiltration facilities for reducing of runoff quantity (II).” Seoul, 342.
National Institute for Disaster Prevention (NIDP). (2000). “Study on the operation and experimental site for the storage and infiltration facilities to reduce runoff quantity.” Seoul, 261.
Soil Conservation Service (SCS). (1986). “Urban hydrology for small watersheds.”, U.S. Dept. of Agriculture, Washington, DC, 164.
Song, J. W., and Im, J. H. (2007). “An experimental study on runoff reducing effect of infiltration-storage system due to rainfall intensity.” J. Kor. Soc. Hazard Mitigat., 7(4), 85–95.
Sonu, J., Yoon, Y. N., Shim, S. B., and Lee, S. T. (1977). “Determination of effective rainfall by US SCS method and regression analysis.” J. Kor. Water Resour. Assoc., 10(2), 101–111.
Walesh, S. G. (1989). Urban surface water management, Wiley, New York, 518.
Yoon, Y. N., and Ahn, J. H. (2005). “Future improvement direction of comprehensive flood control plan.” Mag. Kor. Water Resour. Assoc., 38(4), 20–24.
Information & Authors
Information
Published In
Copyright
© 2013 American Society of Civil Engineers.
History
Received: Oct 23, 2011
Accepted: May 23, 2012
Published online: May 25, 2012
Published in print: Jun 1, 2013
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.