Abstract
This paper investigated an intermediate discontinuity in a frame structure and its capability to mitigate the effects of seismic ground motions. The discontinuity represents a sudden change in the stiffness of the frame. The behavior of a structure after the introduction of discontinuity was studied by means of an archetype dynamically equivalent three-degree-of-freedom model. Two auxiliary systems were introduced to evaluate the effectiveness of the discontinuity. The first auxiliary system represented the structure without discontinuity. The second represented a system in which the part of the structure below the discontinuity is rigid. These two auxiliary systems allowed us to evaluate whether discontinuity is able to reduce the displacements of frame structure. The results were summarized using three gain coefficients that portray the ratio of displacements and drifts with and without the discontinuity. When the gain coefficients are less than unity, the discontinuity improves the dynamic behavior of the frame. To check the effectiveness of the proposed archetype model, results provided by an archetype and by spatial shear-type frames were compared. Then the archetype three-degrees-of-freedom system was used to conduct an extensive parametric analysis by varying geometrical and mechanical parameters. The results were organized in gain maps that represent the contour plot of the gain coefficients. Some maps were built using the spectrum compatibility criterion so that the results depend only on the seismic design spectrum. The gain maps show several ranges of the parameters’ region in which discontinuity is effective.
Get full access to this article
View all available purchase options and get full access to this article.
Data Availability Statement
Data, models, or code generated or used during the study are available from the corresponding author by request, including all the data of the results and the source code of the numerical integration procedure.
References
Aghagholizadeh, M., and N. Makris. 2018. “Earthquake response analysis of yielding structures coupled with vertically restrained rocking walls.” Earthquake Eng. Struct. Dyn. 47 (15): 2965–2984. https://doi.org/10.1002/eqe.3116.
Akcelyan, S., and D. G. Lignos. 2019. “A practical method for seismic retrofit of tall buildings with supplemental damping.” In Proc., 12th Canadian Conf. on Earthquake Engineering. Quèbec: Château Frontenac.
Anajafi, H., and R. Medina. 2018. “Comparison of the seismic performance of a partial mass isolation technique with conventional TMD and base-isolation systems under broad-band and narrow-band excitations.” Eng. Struct. 158 (Mar): 110–123. https://doi.org/10.1016/j.engstruct.2017.12.018.
Bachmann, J. A., M. F. Vassiliou, and B. Stojadinović. 2017. “Dynamics of rocking podium structures.” Earthquake Eng. Struct. Dyn. 46 (14): 2499–2517. https://doi.org/10.1002/eqe.2915.
Chen, H., P. Tan, and F. Zhou. 2017. “An improved response spectrum method for non-classically damped systems.” Bull. Earthquake Eng. 15 (10): 4375–4397. https://doi.org/10.1007/s10518-017-0144-4.
Chey, M.-H., J. G. Chase, J. B. Mander, and A. J. Carr. 2013. “Innovative seismic retrofitting strategy of added stories isolation system.” Front. Struct. Civ. Eng. 7 (1): 13–23. https://doi.org/10.1007/s11709-013-0195-9.
Chopra, A. K. 1995. Dynamics of structures, theory and applications to earthquake engineering. Englewood Cliffs, NJ: Prentice Hall.
Clough, R. W., and J. Penzien. 1995. Dynamics of structures. Berkeley, CA: Computers and Structures.
De Domenico, D., N. Impollonia, and G. Ricciardi. 2018. “Soil-dependent optimum design of a new passive vibration control system combining seismic base isolation with tuned inerter damper.” Soil Dyn. Earthquake Eng. 105 (Feb): 37–53. https://doi.org/10.1016/j.soildyn.2017.11.023.
De Domenico, D., and G. Ricciardi. 2018a. “An enhanced base isolation system equipped with optimal tuned mass damper inerter (TMDI).” Earthquake Eng. Struct. Dyn. 47 (5): 1169–1192. https://doi.org/10.1002/eqe.3011.
De Domenico, D., and G. Ricciardi. 2018b. “Optimal design and seismic performance of tuned mass damper inerter (TMDI) for structures with nonlinear base isolation systems.” Earthquake Eng. Struct. Dyn. 47 (12): 2539–2560. https://doi.org/10.1002/eqe.3098.
Den Hartog, J.-P. 1956. Mechanical vibrations. 4th ed. New York: McGraw-Hill.
Di Egidio, A., S. Pagliaro, and C. Fabrizio. 2021. “Combined use of rocking wall and inerters to improve the seismic response of frame structures.” J. Eng. Mech. 147 (5): 04021016. https://doi.org/10.1061/(ASCE)EM.1943-7889.0001920.
Di Egidio, A., S. Pagliaro, C. Fabrizio, and A. de Leo. 2019. “Dynamic response of a linear two d.o.f. system visco-elastically coupled with a rigid block.” Coupled Syst. Mech. 8 (4): 351–375. https://doi.org/10.12989/csm.2019.8.4.351.
Di Egidio, A., S. Pagliaro, C. Fabrizio, and A. M. de Leo. 2020. “Seismic performance of frame structures coupled with an external rocking wall.” Eng. Struct. 224: 111207. https://doi.org/10.1016/j.engstruct.2020.111207.
Fabrizio, C., A. M. de Leo, and A. Di Egidio. 2019. “Tuned mass damper and base isolation: A unitary approach for the seismic protection of conventional frame structures.” J. Eng. Mech. 145 (4): 04019011. https://doi.org/10.1061/(ASCE)EM.1943-7889.0001581.
Fabrizio, C., A. Di Egidio, and A. M. de Leo. 2017. “Top disconnection versus base disconnection in structures subjected to harmonic base excitation.” Eng. Struct. 152 (Dec): 660–670. https://doi.org/10.1016/j.engstruct.2017.09.041.
Faiella, D., and E. Mele. 2020. “Insights into inter-story isolation design through the analysis of two case studies.” Eng. Struct. 215 (Jul): 110660. https://doi.org/10.1016/j.engstruct.2020.110660.
Feng, M. Q., and A. Mita. 1995. “Vibration control of tall buildings using mega subconfiguration.” J. Eng. Mech. 121 (10): 1082–1088. https://doi.org/10.1061/(ASCE)0733-9399(1995)121:10(1082).
Giaralis, A., and A. A. Taflanidis. 2018. “Optimal tuned mass-damper-inerter (TMDI) design for seismically excited MDOF structures with model uncertainties based on reliability criteria.” Struct. Control Health Monit. 25 (2): e2082. https://doi.org/10.1002/stc.2082.
Hwang, J.-S., and H. J. Kim. 2018. “Mode decomposition of structures with closely distributed modes and nonclassical damping.” Struct. Control Health Monit. 25 (1): e2065. https://doi.org/10.1002/stc.2065.
Iervolino, I., C. Galasso, and E. Cosenza. 2010. “REXEL: Computer aided record selection for code-based seismic structural analysis.” Bull. Earthquake Eng. 8 (2): 339–362. https://doi.org/10.1007/s10518-009-9146-1.
Kawamura, S., R. Sugisaki, K. Ogura, S. Maezawa, S. Tanaka, and A. Yajima. 2000. “Seismic isolation retrofit in Japan.” In Proc. 12th World Conf. on Earthquake Engineering. Auckland, NZ: New Zealand National Society for Earthquake Engineering.
Kelly, J. M. 1990. “Base isolation: Linear theory and design.” Earthquake Spectra 6 (2): 223–244. https://doi.org/10.1193/1.1585566.
Lestuzzi, P., Y. Belmouden, and M. Trueb. 2007. “Non-linear seismic behavior of structures with limited hysteretic energy dissipation capacity.” Bull. Earthquake Eng. 5 (4): 549–569. https://doi.org/10.1007/s10518-007-9050-5.
Makris, N. 2014. “A half-century of rocking isolation.” Earthquakes Struct. 7 (6): 1187–1221. https://doi.org/10.12989/eas.2014.7.6.1187.
Makris, N., and M. Aghagholizadeh. 2017. “The dynamics of an elastic structure coupled with a rocking wall.” Earthquake Eng. Struct. Dyn. 46 (6): 945–962. https://doi.org/10.1002/eqe.2838.
Matta, E., and A. De Stefano. 2009. “Robust design of mass-uncertain rolling-pendulum TMDS for the seismic protection of buildings.” Mech. Syst. Sig. Process. 23 (1): 127–147. https://doi.org/10.1016/j.ymssp.2007.08.012.
Miah, M. S., E. N. Chatzi, V. K. Dertimanis, and F. Weber. 2017. “Real-time experimental validation of a novel semi-active control scheme for vibration mitigation.” Struct. Control Health Monit. 24 (3): e1878. https://doi.org/10.1002/stc.1878.
Miranda, J. C. 2005. “On tuned mass dampers for reducing the seismic response of structures.” Earthquake Eng. Struct. Dyn. 34 (7): 847–865. https://doi.org/10.1002/eqe.461.
Murakami, K., H. Kitamura, H. Ozaki, and T. Teramoto. 2000. “Design and analysis of a building with the middle-story isolation structural system.” In Proc., 12th World Conf. on Earthquake Engineering. Auckland, NZ: New Zealand National Society for Earthquake Engineering.
Pagliaro, S., A. Aloisio, R. Alaggio, and A. Di Egidio. 2020. “Rigid block coupled with a 2 d.o.f. system: Numerical and experimental investigation.” Coupled Syst. Mech. 9 (6): 539–562. https://doi.org/10.12989/CSM.2020.9.6.539.
Rana, R., and T. T. Soong. 1998. “Parametric analysis and simplified design of tuned mass damper.” Eng. Struct. 20 (3): 193–204. https://doi.org/10.1016/S0141-0296(97)00078-3.
Reggio, A., and M. De Angelis. 2015. “Optimal energy-based seismic design of non-conventional tuned mass damper (TMD) implemented via inter-story isolation.” Earthquake Eng. Struct. Dyn. 44 (10): 1623–1642. https://doi.org/10.1002/eqe.2548.
Sadek, F., B. Mohraz, A. W. Taylor, and R. M. Chung. 1997. “A method of estimating the parameters of tuned mass dampers for seismic applications.” Earthquake Eng. Struct. Dyn. 26 (6): 617–635. https://doi.org/10.1002/(SICI)1096-9845(199706)26:6%3C617::AID-EQE664%3E3.0.CO;2-Z.
Sueoka, T., S. Torii, and Y. Tsuneki. 2004. “The application of response control design using middle-story isolation system to high rise building.” In Proc., 13th World Conf. on Earthquake Engineering. Vancouver, BC, Canada: Canadian Association for Earthquake Engineering.
Taniguchi, T., A. Der Kiureghian, and M. Melkumyan. 2008. “Effect of tuned mass damper on displacement demand of base-isolated structures.” Eng. Struct. 30 (12): 3478–3488. https://doi.org/10.1016/j.engstruct.2008.05.027.
Tsai, H.-C. 1995. “The effect of tuned-mass dampers on the seismic response of base-isolated structures.” Int. J. Solid Struct. 32 (8–9): 1195–1210. https://doi.org/10.1016/0020-7683(94)00150-U.
Tsai, H.-C., and J. M. Kelly. 1988. “Non-classical damping in dynamic analysis of base isolated structures with internal equipment.” Earthquake Eng. Struct. Dyn. 16 (1): 29–43. https://doi.org/10.1002/eqe.4290160104.
Tsiavos, A., P. Haladij, A. Sextos, and N. A. Alexander. 2020. “Analytical investigation of the effect of a deformable sliding layer on the dynamic response of seismically isolated structures.” Structures 27 (Oct): 2426–2436. https://doi.org/10.1016/j.istruc.2020.08.016.
Tsuneki, Y., S. Torii, K. Murakami, and T. Sueoka. 2009. “Middle-story isolated structural system of high-rise building.” J. Disaster Res. 4 (3): 229–238. https://doi.org/10.20965/jdr.2009.p0229.
Villaverde, R., M. Aguirre, and C. Hamilton. 2005. “Aseismic roof isolation system built with steel oval elements.” Earthquake Spectra 21 (1): 225–241. https://doi.org/10.1193/1.1850528.
Villaverde, R., and G. Mosqueda. 1999. “Aseismic roof isolation system: Analytic and shake table studies.” Earthquake Eng. Struct. Dyn. 28 (3): 217–234. https://doi.org/10.1002/(SICI)1096-9845(199903)28:3%3C217::AID-EQE813%3E3.0.CO;2-G.
Wang, S.-J., K.-C. Chang, J.-S. Hwang, J.-Y. Hsiao, B.-H. Lee, and Y.-C. Hung. 2012. “Dynamic behavior of a building structure tested with base and mid-story isolation systems.” Eng. Struct. 42 (Sep): 420–433. https://doi.org/10.1016/j.engstruct.2012.04.035.
Wang, S.-J., K.-C. Chang, J.-S. Hwang, and B.-H. Lee. 2011. “Simplified analysis of mid-story seismically isolated buildings.” Earthquake Eng. Struct. Dyn. 40 (2): 119–133. https://doi.org/10.1002/eqe.1004.
Wang, S.-J., J.-S. Hwang, K.-C. Chang, M.-H. Lin, and B.-H. Lee. 2013. “Analytical and experimental studies on midstory isolated buildings with modal coupling effect.” Earthquake Eng. Struct. Dyn. 42 (2): 201–219. https://doi.org/10.1002/eqe.2203.
Warburton, G. B., and S. R. Soni. 1977. “Errors in response calculations for non-classically damped structures.” Earthquake Eng. Struct. Dyn. 5 (4): 365–376. https://doi.org/10.1002/eqe.4290050404.
Ziyaeifar, M., and H. N. Noguchi. 1998. “Partial mass isolation in tall buildings.” Earthquake Eng. Struct. Dyn. 27 (1): 49–65. https://doi.org/10.1002/(SICI)1096-9845(199801)27:1%3C49::AID-EQE718%3E3.0.CO;2-J.
Information & Authors
Information
Published In
Copyright
© 2022 American Society of Civil Engineers.
History
Received: May 3, 2021
Accepted: Nov 11, 2021
Published online: Jan 5, 2022
Published in print: Mar 1, 2022
Discussion open until: Jun 5, 2022
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.
Cited by
- A.Di Egidio, S. Pagliaro, A. Contento, Improvement of the seismic response of frame structures through the coupling with an external structure equipped with inerter, Procedia Structural Integrity, 10.1016/j.prostr.2023.01.273, 44, (2136-2143), (2023).
- Michela Basili, Maurizio De Angelis, Experimental Dynamic Response of a Multi-Story Frame Structure Equipped with Non-Conventional TMD Implemented via Inter-Story Isolation, Applied Sciences, 10.3390/app12189153, 12, 18, (9153), (2022).