Erratum for “New Model for Ductile Fracture of Metal Alloys. II: Reverse Loading” by Huajie Wen and Hussam Mahmoud
Test number | Specimen description (mm) | Load type | Experimental fracture displacement | Fracture displacement by | |
---|---|---|---|---|---|
Eq. (24) | Eq. (28) | ||||
6 | CTF | (), [9,0.2] | (), [8,0.102] | (), [9,0.2] | |
(), [9,0.2] | |||||
7 | CTF | (), [7,0.2] | (), [7,0.248] | (), [7,0.064] | |
(), [7,0.3] | |||||
8 | C-PTF | 6(), [0.6] | 6(), [0.65] | 6(), [0.3] | |
6(), [0.6] |
Note: CTF = cyclic to failure; C-PTF = cyclic then pulled to failure. The specimens are cycled between displacement limits and subjected to tension load at the incipient stages. The displacements history is described with the following examples: for CTF, (), [9,0.2] refers to specimen cycled between and 0.26 mm until failure is observed on nine cycles at a 0.2-mm displacement; for C-PTF, 6(), [0.6] refers to a specimen first subjected to six cycles with displacement limits of and 0.25 mm and then pulled to failure at a 0.6-mm displacement.