Field Testing of a Small-Scale Continuous-Flow Wastewater Electrodisinfection Unit Using Direct Current
Publication: Journal of Environmental Engineering
Volume 144, Issue 1
Abstract
This paper describes field testing of a small-scale, continuous-flow electrodisinfection reactor assembled with four -coated titanium plates and operated in bipolar mode using direct current, installed at the Marrero wastewater treatment plant in Marrero, Louisiana. The objective of this testing was to demonstrate the technical feasibility of replacing the current wastewater-effluent hypochlorination process with this new disinfection technology. Bacterial inactivation and chlorine production were the main parameters recorded. The experiments reported in this study demonstrate that the electrodisinfection process can meet and exceed 5-log coliform removal in a short contact time, thereby proving to be efficient enough to be considered as an alternative to chlorination in wastewater treatment facilities. Optimum operational conditions for fluid retention time, and volumetric current density and rate, were stablished from the experimental results. The following design recommendations summarize these findings: retention time of , minimum volumetric current density of , and minimum volumetric current rate of . Implementation of these operational conditions in the field yielded excellent disinfection efficiencies and low chlorine residual production.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
Jefferson Parish Department of Sewerage provided funding to conduct the experiments described in this study. The unconditional support and assistance provided by the Marrero Wastewater Treatment Plant Superintendent, Mr. Ronald Huffman, is gratefully acknowledged.
References
Acosta, J. (2014). “Electrodisinfection of municipal wastewaters using direct current.” M.S. thesis, Univ. of New Orleans, New Orleans, LA.
Chavez, X. (2014). “Electrochemical disinfection of municipal waste water using alternating current.” M.S. thesis, Univ. of New Orleans, New Orleans, LA.
Kraft, A., et al. (1999a). “Electrochemical water disinfection. I: Hypochlorite production from very dilute chloride solutions.” J. Appl. Electrochem., 29(7), 859–866.
Kraft, A. (2008). “Electrochemical water disinfection: A short review.” Platinum Met. Rev., 52(3), 177–185.
Kraft, A., Blaschke, M., Kreysig, D., Sandt, B., Schröder, F., and Rennau, J. (1999b). “Electro-chemical water disinfection. II: Hypochlorite production from potable water, chlorine consumption and the problem of calcareous deposits.” J. Appl. Electrochem., 29(8), 895–902.
Kraft, A., Wünsche, M., Stadelmann, M., and Blaschke, M. (2003). “Electrochemical water disinfection.” Recent Res. Devel. Electrochem., 6, 27–55.
LDEQ (Louisiana Department of Environmental Quality). (2004). “Louisiana pollutant discharge elimination system (LPDES) permit to discharge treated sanitary wastewater into the Mississippi River from a publicly owned treatment works serving the Marrero area of Jefferson Parish.”, Baton Rouge, LA.
Li, X., Diao, H., Fan, F., Gu, J., Ding, F., and Tong, A. (2004). “Electrochemical wastewater disinfection: Identification of its principal germicidal actions.” J. Environ. Eng., 1217–1221.
McCraven, K. (2009). “Electrodisinfection of ballast water.” M.S. thesis, Univ. of New Orleans, New Orleans, LA.
Patermarakis, G., and Fountoukidis, E. (1990). “Disinfection of water by electrochemical treatment.” Water Res., 24(12), 1491–1496.
Peterson, M. R. (2005). “Electrodisinfection of municipal wastewater.” M.S. thesis, Univ. of New Orleans, New Orleans, LA.
Pulido, M. E. (2005). “Evaluation of an electrodisinfection technology as an alternative to chlorination of municipal wastewater effluents.” Ph.D. dissertation, Univ. of New Orleans, New Orleans, LA.
Rajeshwar, K., and Ibáñez, J. (1997). Environmental electrochemistry: Fundamentals and applications in pollution sensors and abatement, Elsevier, Amsterdam, Netherlands, 109.
Rincon, G., and La Motta, E. (2014). “Simultaneous removal of oil and grease, and heavy metals from artificial bilge water using electro-coagulation/flotation.” J. Environ. Manage., 144, 42–50.
RWO-Veolia. (2016). “Clean ballast water treatment.” ⟨http://www.rwo.de/rwo/ressources/files/1/22527-RWO-Veolia-CleanBallast_8_2016_WEB.pdf⟩ (Dec. 14, 2016).
USEPA (U.S. Environmental Protection Agency). (1999). “Wastewater technology fact sheet chlorine disinfection.”, Washington, DC.
USEPA (U.S. Environmental Protection Agency). (2009). “Method 1603: Escherichia coli (E. coli) in water by membrane filtration using modified membrane-thermotolerant Escherichia coli agar (modified mTEC).”, Washington, DC.
Information & Authors
Information
Published In
Copyright
©2017 American Society of Civil Engineers.
History
Received: Jun 16, 2016
Accepted: Jul 5, 2017
Published online: Nov 14, 2017
Published in print: Jan 1, 2018
Discussion open until: Apr 14, 2018
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.