Modeling and Simulations of Flow Pattern, Chlorine Concentration, and Mean Age Distributions in Potable Water Service Reservoir of Singapore
Publication: Journal of Environmental Engineering
Volume 137, Issue 7
Abstract
Study of flow pattern and chlorine distribution is of major interest in the characterization, design, and evaluation of service conditions of a service reservoir. With the advancement of computational science and resources, the computational fluid dynamics (CFD) method could be a reliable alternative to flow and tracer tests. A salient feature of flow in the service reservoir is the changing inflow and outflow caused by variations in water demand and supply. To overcome the challenge of tracking water-level variations, two different numerical methods (i.e., multiphase analysis and dynamic meshes) were implemented in this study. The multiphase analysis demonstrates that sloshing of water is not significant because of the relatively low velocity in contrast to the large dimensions of the service reservoir. Therefore, it is valid to assume that the water-air interface remains as a horizontal plane. Dynamic meshes are then used to track the water-level variations to reduce the computational cost. The predicted chlorine concentration at the outlet matches well with that of on-site measurement. The study on a common service condition reveals short-circuiting of the flow. The subsequent formation of recirculation zones implies poor lateral and moderate vertical mixings, which result in nonuniform chlorine distribution in the reservoir. To provide the spatial distributions of the local mean residence time of the chlorine, the “mean age” concept was introduced in the present study. It can be used as a quantitative indicator to guide the design of service reservoirs for achieving a homogenous chlorine distribution.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The authors extend appreciation to the Public Utilities Board of Singapore for the support of this research. Special thanks are given to Mr. Gek Hee Tan, Ms. Joyce Lau, Mr. Khee Lin Yeo, Miss Xingxia Chen, and Mr. Kim Hoo Lee for sharing their knowledge.
References
Baawain, M. S., Mohamed, G. E.-D., and Smith, D. W. (2006). “Computational fluid dynamics application in modeling and improving the performance of a storage reservoir used as a contact chamber for microorganism inactivation.” J. Environ. Eng. Sci., 5(2), 151–162.
Baléo, J. N., and Cloirec, P. L. (2000). “Numerical simulation of the spatial distribution of mean residence time in complex flows through porous media.” Prog. Theor. Phys. Suppl., 138, 690–695.
Baléo, J. N., Humeau, P., and Cloirec, P. L. (2001). “Numerical and experimental hydrodynamic studies of a lagoon pilot.” Water Res., 35(9), 2268–2276.
Beckers, J. M., Delhez, E., and Deleersnijder, E. (2001). “Some properties of generalized age-distribution equations in fluid dynamics.” SIAM J. Appl. Math., 61(5), 1526–1544.
Courtis, B. J., West, J. R., and Bridgeman, J. (2009). “Temporal and spatial variations in bulk chlorine decay within a water supply system.” J. Environ. Eng., 135(3), 147–152.
Deleersnijder, E., Campin, J. M., and Delhez, E. J. M. (2001). “The concept of age in marine modeling, I. Theory and preliminary model results.” J. Mar. Syst., 28(3–4), 229–267.
Fisher, I., Sathasivan, A., Chua, P., and Kastl, G. (2009). “Effects of stratification and chloramine decay in distribution system service reservoirs.” Water Res., 43(5), 1403–1413.
Goula, A. M., Kostoglou, M., Karapantsio, T. D., and Zouboulis, A. I. (2008). “The effect of influent temperature variations in a sedimentation tank for potable water treatment–A computational fluid dynamic study.” Water Res., 42(13), 3405–3414.
Greene, D. J., Farouk, B., and Haas, C. N. (2004). “CFD design approach: For chlorine disinfection processes.” J. Am. Water Works Assoc., 96(8), 138–150.
Hua, F., West, J. R., Barker, R. A., and Forster, C. F. (1999). “Modeling of chlorine decay in municipal water supplies.” Water Res., 33(12), 2735–2746.
Khan, L. A., Wicklein, E. A., and Teixeira, E. C. (2006). “Validation of a three-dimensional computational fluid dynamics model of a contact tank.” J. Hydraul. Eng., 132(7), 741–746.
Menter, F. R. (1994). “Two-equation eddy-viscosity turbulence models for engineering applications.” AIAA J., 32(8), 1598–1605.
Peplinski, D. K., and Ducoste, J. J. (2002). “Modeling of disinfection contactor hydraulics under uncertainty.” J. Environ. Eng., 128(11), 1056–1067.
Powell, J. C., Hallam, N. B., West, J. R., Forster, C. F., and Simms, J. (2000). “Factors which control bulk chlorine decay rates.” Water Res., 34(1), 117–126.
Ta, C. T., and Brignal, W. J. (1998). “Application of computational fluid dynamics technique to storage reservoir studies.” Water Sci. Technol., 37(2), 219–226.
Templeton, M. R., Hofmann, R., and Andrews, R. C. (2006). “Case study comparisons of computational fluid dynamics (CFD) modeling versus tracer testing for determining clearwell residence times in drinking water treatment.” J. Environ. Eng. Sci., 5(6), 529–536.
Yapici, K., Bulent, K., Schäfer, M., and Uludag, Y. (2008). “Numerical investigation of the effect of the Rushton type turbine design factors on agitated tank flow characteristics.” Chem. Eng. Proc., 47(8), 1340–1355.
Zhang, X., Sudharsan, N. M., Ajaykumar, R., and Kumar, K. (2005). “Simulation of free-surface flow in a tank using the Navier-Stokes model and unstructured finite volume method.” J. Mech. Eng. Sci., 219, 251–266.
Information & Authors
Information
Published In
Copyright
© 2011 American Society of Civil Engineers.
History
Received: Jul 23, 2010
Accepted: Jan 10, 2011
Published online: Jan 12, 2011
Published in print: Jul 1, 2011
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.