Technical Papers
Jan 5, 2015

Case Study of Industrial-Building Energy Performance in a Cold-Climate Region in a Developing Country

Publication: Journal of Performance of Constructed Facilities
Volume 30, Issue 2

Abstract

Most industrial buildings in developing countries such as China have excessively high energy consumption, and the portion used by HVAC systems is significant. This investigation used a winery building in a cold region in northern China as a case study to analyze industrial-building energy performance. A lack of communication, cultural differences in design requirements, and poor construction quality were the primary factors that led to excessive air leakage, insufficient building insulation, and poor indoor air distribution. This investigation developed a set of methods to evaluate building-energy use, air leakage, condensation, thermal insulation, and indoor air distribution. A number of remedial measures were proposed, and some of them have been proven to be effective. In developing countries such as China, the lessons learned in this project will be useful for designing and constructing energy-efficient industrial buildings with desirable indoor environments.

Get full access to this article

View all available purchase options and get full access to this article.

Acknowledgments

The authors gratefully acknowledge the contributions made by Mr. Wei Huang of the China Metallurgy Architecture Design Institute, Ms. Yueli Liu of the Chinese Academy of Building Science, and Prof. Junjie Liu of Tianjin University. Several graduate and undergraduate students from Tianjin University helped with the experimental measurements in the winery building. Their contributions are appreciated. The authors are also thankful to the owner and general contractor of the winery building, who provided convenient access and invaluable assistance for this study.

References

Aksoy, U. T. (2012). “A numerical analysis for energy savings of different oriented and insulated walls in the cold climate of Turkey-simulation-based study.” Energy Build., 50, 243–250.
ANSYS Fluent version 12.1 [Computer software]. Commonwealth of Pennsylvania, ANSYS Inc.
ASTM. (2006). “Test method for determining air leakage rate by fan pressurization.”, West Conshohocken, PA.
Binamu, A. H. (2002). Integrating building design properties “air tightness” and ventilation heat recovery for minimum heating energy consumption in cold climates, Tampere Univ. of Technology, Tampere, Finland.
Bolattürk, A. (2006). “Determination of optimum insulation thickness for building walls with respect to various fuels and climate zones in Turkey.” Appl. Thermal Eng., 26(11–12), 1301–1309.
Demokritou, P., Yang, C., Chen, Q., and John, D. (2002). “An experimental method for contaminant dispersal characterization in large industrial buildings for indoor air quality (IAQ) applications.” Build. Environ., 37(3), 305–312.
Emmerich, S. J., and Persily, A. K. (2005). “Air tightness of commercial buildings in the US.” 26th AIVC Conf., Brussels, Belgium.
Energyplus 2.0 [Computer software]. DOE (Dept. of Energy).
Huang, C., et al. (2007). “Measurements of indoor thermal environment and energy analysis in a large space building in typical seasons.” Build. Environ., 42(5), 1869–1877.
Janssens, A., and Hens, H. (2003). “Interstitial condensation due to air leakage: A sensitivity analysis.” J. Thermal Envelope Build. Sci., 27(1), 15–29.
Jokisalu, J., and Kurnitski, J. (2002). Simulation of energy consumption in typical Finnish detached house (report B, 2002), Helsinki Univ. of Technology, HVAC Laboratory, Espoo, Finland.
Jones, P. J., and O’Sullivan, P. E. (1987). “Energy efficient design of industrial buildings.” Build. Environ., 22(3), 181–187.
Joo, J., Zheng, Q., Lee, G., Kim, J. T., and Kim, S. (2012). “Optimum energy use to satisfy indoor air quality needs.” Energy Build., 46, 62–67.
Kalamees, T. (2007). “Air tightness and air leakages of new lightweight single-family detached houses in Estonia.” Build. Environ., 42(6), 2369–2377.
Lam, J. C., Wan, K. K. W., Tsang, C. L., and Yang, L. (2008). “Building energy efficiency in different climates.” Energy Conversion Manage., 49(8), 2354–2366.
Lau, J., and Chen, Q. (2006). “Energy analysis for workshops with floor-supply displacement ventilation under the U.S. climates.” Energy Build., 38(10), 1212–1219.
Lucas, F., Adelard, L., Garde, F., and Boyer, H. (2002). “Study of moisture in buildings for hot humid climates.” Energy Build., 34(4), 345–355.
MOHURD (Ministry of Housing, and Urban-Rural Development of the People’s Republic of China). (2009). JGJ.T 117-2009 Standard for energy efficiency test of public buildings, China Architecture and Building Press, Beijing (in Chinese).
Montoya, M. I., Pastor, E., Carrie, R. F., Guyot, G., and Planas, E. (2010). “Air leakage in Catalan dwellings: Developing an airtightness model and leakage airflow predictions.” Build. Environ., 45(6), 1458–1469.
National Bureau of Statistics of China. (2013). “Accumulated floor space of buildings completed by construction enterprises by region.” 〈http://219.235.129.58/clicksortall.do.〉 (May 1, 2013) (in Chinese).
Tanasić, N., Jankes, G., and Skistad, H. (2011). “CFD analysis and airflow measurements to approach large industrial halls energy efficiency: A case study of a cardboard mill hall.” Energy Build., 43(6), 1200–1206.
Wang, H. W., Zheng, Y. D., Feng, G. H., and Li, X. L. (2010). “The structure of typical industrial buildings in Shenyang and investigation of thermal performance.” Ind. Constr., 40(S1), 66–68.
Wang, M., and Chen, Q. (2009). “Assessment of various turbulence models for transitional flows in enclosed environment.” HVAC&R Res., 15(6), 1099–1119.
Wei, Y. (2009). Simulation of indoor thermal environment of natatorium with under floor air distribution system and energy consumption analysis, Xi’an Univ. of Architecture and Technology, China (in Chinese).
Wu, W., Li, R., and Li, L. (2010). “Energy efficiency reformation for external structures of old factory buildings in severe cold region.” Ind. Constr., 9(12), 8–12 (in Chinese).
Xiao, X., Chen, H., and Liang, P. (2012). Review of energy conservation design of industrial buildings in China, China Coal Society, Beijing.
Xie, S. (2009). Field measurement analysis and numerical simulation of heat moisture environment in paper industrial plants under high temperature and humidity environment, Hunan Univ., China (in Chinese).
Xu, W. (2012). “HVAC system accounting for 50% of total building energy consumption.”, 〈http://www.china5e.com/news/news-256324-1.html〉 (May 1, 2013) (in Chinese).
Yao, R., Li, B., and Steemers, K. (2005). “Energy policy and standard for built environment in China.” Renew. Energy, 30(13), 1973–1988.
Yu, J., Yang, C., Tian, L., and Liao, D. (2009). “A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of China.” Appl. Energy, 86(11), 2520–2529.
Zhang, Z., Zhai, Z., and Chen, Q. (2007). “Evaluation of various CFD models in predicting room airflow and turbulence.” HVAC&R Res., 13(6), 853–870.
Zheng, J., and Peng, P. (2005). “Energy-saving measures of HVAC systems.” Intell. Build. City Inform., (10), 94–97 (in Chinese).

Information & Authors

Information

Published In

Go to Journal of Performance of Constructed Facilities
Journal of Performance of Constructed Facilities
Volume 30Issue 2April 2016

History

Received: Jul 7, 2014
Accepted: Dec 2, 2014
Published online: Jan 5, 2015
Discussion open until: Jun 5, 2015
Published in print: Apr 1, 2016

Permissions

Request permissions for this article.

Authors

Affiliations

Hao Zhou
Ph.D. Candidate, Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin Univ., Tianjin 300072, China.
Weijuan Li
Graduate Student, Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin Univ., Tianjin 300072, China.
Yuanyi Chen
Graduate Student, Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin Univ., Tianjin 300072, China.
Dayi Lai
Graduate Student, Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin Univ., Tianjin 300072, China.
Hejiang Sun [email protected]
Associate Professor, Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin Univ., Tianjin 300072, China (corresponding author). E-mail: [email protected]
Qingyan Chen
Professor, School of Mechanical Engineering, Purdue Univ., 585 Purdue Mall, West Lafayette, IN 47907-2088; and Professor, Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin Univ., Tianjin 300072, China.

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

Cited by

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share