Seismic Performance Assessment of Partially Grouted, Nominally Reinforced Concrete-Masonry Structural Walls Using Shake Table Testing
Publication: Journal of Performance of Constructed Facilities
Volume 28, Issue 2
Abstract
An experimental program has been carried out to study the performance of partially grouted, nominally reinforced (PG-NR) concrete block structural walls under in-plane seismic loading on a shake table. Five reduced-scale structural walls were constructed and tested under scaled versions of the 1940 El Centro, California earthquake, using its N-S component record with a constant axial compression load that represented a single-story building. The test walls were grouped into three categories. Type I and III walls had reinforcement at the wall end cells only, with vertical reinforcement ratios of 0.07 and 0.12%, respectively, based on the gross cross-sectional area of the walls. Type II walls were similar to Type I walls, but with an additional reinforcement bar located midlength of the wall with a vertical reinforcement ratio of 0.10%, also based on the gross cross-sectional area of the wall. The experimental results were documented and discussed with respect to wall lateral load capacity, stiffness degradation, period shift, displacement ductility levels attained, and relevant seismic-force reduction factors. The test results showed that PG-NR masonry walls can comprise a ductile seismic force-resisting system. Subsequently, PG-NR masonry walls have the potential to bridge the gap between unreinforced and reinforced masonry systems. The use of PG-NR masonry also results in a reduced cost compared with traditional reinforced masonry systems used in seismic zones that are typically fully grouted within the plastic hinge zones and require higher reinforcement ratios.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
Financial support has been provided by the McMaster University Centre for Effective Design of Structures (CEDS) funded through the Ontario Research and Development Challenge Fund (ORDCF), a program of the Ministry of Research and Innovation (MRI), as well as the Natural Sciences and Engineering Research Council (NSERC) of Canada. Provision of mason time by the Canada Masonry Design Centre (CMDC) is appreciated. The supply of scaled blocks by the Canadian Concrete Masonry Producers Association (CCMPA) is gratefully acknowledged.
References
Abrams, D. P., and Paulson, T. J. (1991). “Modeling earthquake response of concrete masonry building structures.” ACI Struct. J., 88(4), 475–485.
Canadian Standards Association (CSA). (2004a). “Design of masonry structures.” CSA S304.1-04, Mississauga, ON, Canada.
Canadian Standards Association (CSA). (2004b). “Mortar and grout for unit masonry.” CSA A179-04, Mississauga, ON, Canada.
Drysdale, R. G., and Hamid, A. A. (2005). Masonry structures: Behavior and design, Canadian Ed., Canadian Masonry and Design Centre, Mississauga, ON, Canada.
ElGawady, M. A., Lestuzzi, P., and Badoux, M. (2005). “Performances of URM walls under in-plane seismic loading.” TMS J., 28(1), 95–114.
Ghanem, G. M., Salama, A. E., Elmagid, S. A., and Hamid, A. A. (1993). “Effect of axial compression on the behavior of partially reinforced masonry shear walls.” Proc., 6th North American Masonry Conf., The Masonry Society, Boulder, CO, 1145–1157.
Haider, W., and Dhanasekar, M. (2004). “Experimental study of monotonically loaded wide spaced reinforced masonry shear walls.” Austr. J. Struct. Eng., 5(2), 101–118.
Hamid, A. A., and Chandrakeerthy, S. R. (1992). “Compressive strength of partially grouted concrete masonry using small scale wall elements.” TMS J., 11(1), 75–85.
Harris, H. G., and Sabnis, G. M. (1999). Structural modeling and experimental techniques, 2nd Ed., CRC Press, Boca Raton, FL.
Maleki, M. (2008). “Behavior of partially grouted reinforced masonry shear walls under cyclic reversed loading.” Ph.D. thesis, Dept. of Civil Engineering, McMaster Univ., Hamilton, ON, Canada.
Matsumura, A. (1985). “Effect of shear reinforcement in concrete masonry walls.” Proc., 1st Joint Technical Coordinating Committee on Masonry Research, U.S.–Japan Coordinated Earthquake Research Program, National Science Foundation, Arlington, VA, and Japanese Ministry of Construction, Tokyo, 1–7.
Minaie, E., Mota, M., Moon, F. L., and Hamid, A. A. (2010). “In-plane behavior of partially grouted reinforced concrete masonry shear walls.” J. Struct. Eng., 1089–1097.
Mirza, M. S., Harris, H. G., and Sabnis, G. M. (1979). “Structural models in earthquake engineering.” Proc., 3rd Canadian Conf. of Earthquake Engineering, Vol. 1, Canadian National Committee for Earthquake Engineering, Ottawa, 511–549.
National Research Council (NRC). (2010). National building code of Canada (NBCC), Montreal.
Nolph, S. M., and ElGawady, M. A. (2012). “Static cyclic response of partially grouted masonry shear walls.” J. Struct. Eng., 864–879.
Paulay, T., and Priestley, M. J. N. (1992). Seismic design of reinforced concrete and masonry buildings, Wiley, New York.
Priestley, M. J. N., Calvi, G. M., and Kowalsky, M. J. (2007). Displacement-based seismic design of structures, IUSS Press, Pavia, Italy.
Schultz, A. E. (1994). “Seismic resistance of partially-grouted masonry shear walls.” Proc., Structural Concrete and Masonry, ASCE Structures Congress XIV, ASCE, Reston, VA, 211–222.
Schultz, A. E., and Hutchinson, R. S. (1998). “Seismic performance of masonry walls with bed joint reinforcement.” Proc., Structural Engineers World Conf., San Francisco, Elsevier Science, Dordrecht, Netherlands. T119-4.
Shedid, M. T., El-Dakhakhni, W. W., and Drysdale, R. G. (2010). “Alternative strategies to enhance the seismic performance of reinforced concrete-block shear wall systems.” J. Struct. Eng., 676–689.
Thurston, S. J., and Hutchison, D. L. (1982). “Reinforced masonry shear walls: Cyclic load tests in contraflexure.” Bull. NZSEE, 15(1), 27–45.
Voon, K. C. (2007) “In-plane seismic design of concrete masonry structures.” Ph.D. thesis, Dept. of Civil and Environmental Engineering, Univ. of Auckland, Auckland, New Zealand.
Yancey, C. W. C., and Scribner, C. F. (1989). “Influence of horizontal reinforcement on shear resistance of concrete block masonry walls.” NISTER 89-4202, NIST, Gaithersburg, MD.
Zarnic, R., Gostic, S., Crewe, A. J., and Taylor, C. A. (2001). “Shaking table tests of 1:4 reduced-scale models of masonry infilled reinforced concrete frame buildings.” Earthquake Eng. Struct. Dynam., 30(5–6), 819–834.
Information & Authors
Information
Published In
Copyright
© 2014 American Society of Civil Engineers.
History
Received: Mar 19, 2012
Accepted: Oct 30, 2012
Published online: Nov 3, 2012
Published in print: Apr 1, 2014
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.