TECHNICAL PAPERS
Jul 15, 2011

Assessment of Air Quality and Performance of Central Ventilation System

Publication: Journal of Performance of Constructed Facilities
Volume 25, Issue 4

Abstract

Central HVAC is a critical constructed facility in the built environment, yet polluted air quality has been causing environment, health, and safety problems to end-users worldwide, particularly in multistory commercial buildings with such systems installed. An index system was introduced in Hong Kong to measure the external air quality, but no system has yet been introduced for measuring internal air quality, nor the legislation to control it. The Hong Kong government states that more than 32% of commercial buildings and 37% of shopping arcades have sick building syndrome, which leads to nausea, dizziness, headaches, sore throats, nose irritation, sinus congestion, and other symptoms in the occupiers. In this study, the major causes, design, construction, users’ habitual modes, and mitigating measures will be investigated, with supporting case studies in Hong Kong. A preliminary investigation, air sample analysis, and end-users’ feedback from questionnaires will be gathered and analyzed to establish a long-term solution for air quality problems.

Get full access to this article

View all available purchase options and get full access to this article.

References

American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). (2004a). “Design for acceptable indoor air quality.” ANSI/ASHRAE 62-2004, Atlanta.
American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). (2004b). “Ventilation for acceptable indoor air quality.” ANSI/ASHRAE 62.1-2004, Atlanta.
Black, M. S., and Bayer, C. W. (1986). “Formaldehyde and other VOC exposures from consumer products.” Proc., ASHRAE IAQ ‘86: Managing Indoor Air for Health and Energy Conservation, 454–468.
Boeniger, M. (1995). “Report: Ozone generators not effective, pose added health risk.” Indoor Air Quality Update, 8(9), 1–3.
Burton, D. J. (1993). IAQ and HVAC workbook, IVE, Inc., UT.
Chau, C. K., Tu, E. Y, Chan, D. Y., and Burnett, J (2002). “Estimating the total exposure to air pollutants for different population age groups in Hong Kong.” Environ. Int., 27(8), 617–630.
Clausen, G. H., Fanger, P. O., Cain, W. S., and Leader, B. P. (1987). “Stability of tobacco smoke odor in enclosed spaces.” Proc., Indoor Air ‘87: 4th Int. Conf. on Indoor Air Quality and Climate.
Colls, J. (2002). Air pollution, 2nd Ed., Spon, London.
Committee of European Standardization (CEN). (1999). “Ventilation for buildings: Design criteria for the indoor environment.” PD CR1752, Brussels, Belgium.
Crandall, M., and Sieber, W. (1996). “The National Institute for Occupational Safety and Health indoor environmental evaluation experience. Part 1: Building environmental evaluations.” Appl. Occup. Environ. Hyg., 11(6), 533–539.
Environment Australia. (2001). 〈http://environmentaustralia.com.au/?q=home〉.
Godish, T. (2004). Air quality, 4th Ed., Lewis, Boca Raton, FL.
Hansen, D. L. (1999). Indoor air quality issues, Taylor and Francis, New York.
Health Canada. (1995). “Indoor air quality in office buildings: A technical guide.” Ottawa, Canada.
Hong Kong Census and Statistics Department (HKCSD). (1994). “Social data collected by the general household survey.” Special Topics Rep. No. 10 and 11, Social Analysis and Research Section, Hong Kong.
Hong Kong Environmental Protection Department (HKEPD). (1997). “Final report: Consultancy study of indoor air pollution in offices and public places in Hong Kong.” Agreement No. CE 14/95, Hong Kong.
Hong Kong Environmental Protection Department (HKEPD). (2003a). “Guidance notes for the management of indoor air quality in offices and public places.” Air Services Group, Hong Kong.
Hong Kong Environmental Protection Department (HKEPD). (2003b). “Indoor air quality certification scheme for offices and public places.” Indoor Air Quality Management Group (IAQMG), Hong Kong.
Hong Kong Environmental Protection Department (HKEPD). (2003c). “Environment Hong Kong.” Air Services Group, Indoor Air Quality Information Centre.
Law, A. K. Y., Chau, C. K., and Chan, G. Y. S. (2001). “Characteristics of bioaerosol profile in office buildings in Hong Kong.” Build. Environ., 36(4), 527–541.
Malkin, R., Wilcox, T., and Sieber, W. (1996). “The National Institute for Occupational Safety and Health indoor environmental evaluation experience. Part 2: Symptom prevalence.” Appl. Occup. Environ. Hyg., 11(6), 540–545.
McGranahan, G., and Murray, F., eds. (2003). Air pollution and health in rapidly developing countries, Earthscan, London.
Mclius, J., Wallingford, K., Kccnlyside, R., and Carpenter, J. (1984). “Indoor air quality: The NIOSH experience.” Proc., American Conf. of Governmental Industrial Hygienists, Vol. 10, 3–7.
Persily, A. K. (1997). “Evaluating building IAQ and ventilation with indoor carbon dioxide.” ASHRAE Trans., 103(2), 193–203.
Scitz, T. A. (1990). “NIOSH indoor air quality investigations: 1971 through 1988.” Proc., Indoor Air Quality Int. Symp., National Institute for Occupational Safety and Health, Cincinnati, 163–171.
Seino, K., Takano, T., Nakamura, K., and Watanabe, M. (2005). “An evidential example of airborne bacteria in a crowded, underground public concourse in Tokyo.” Atmos. Environ., 39(2), 337–341.
Sieber, W., et al. (1996). The National Institute for Occupational Safety and Health indoor environmental evaluation experience: Associations between environmental factors and self-reported health conditions.” Appl. Occup. Environ. Hyg., 11(12), 1387–1392.
Tucker, W. G. (1986). “Research overview: Source of indoor air pollutants.” Proc., IAQ ‘86: Managing Indoor Air for Health and Energy Conservation, 395–404.
U.S. EPA. (1989). “Report to Congress on indoor air quality.” EPA/400/1-89/001, Office of Air and Radiation and Office of Research and Development, Washington, DC.
U.S. EPA, U.S. Public Health Service, National Environmental Health Association. (1991). “Introduction to indoor air quality, a reference manual.” EPA/400/3-91/003, Washington, DC, 297.
U.S. EPA, U.S. Dept. of Health and Human Services. (1991). “Building air quality: A guide for building owners and facility managers.” Indoor Air Division, National Institute for Occupational Safety and Health, Washington, DC.
Womble, S. E., Girman, J. R., Ronca, E. L., Axelrad, R., Brightman, H. S., and McCarthy, J. F. (1995). “Developing baseline information on buildings and indoor air quality (BASE '94): Part I—Study design, building selection, and building descriptions.” Proc., Healthy Buildings ’95, Milan, Italy.
World Health Organization (WHO). (1986).”Indoor air quality research.” EURO reports and studies 103, Copenhagen, Denmark.
World Health Organization (WHO). (2000). “Indoor air pollutants, exposure and health effects.” EURO reports and studies 78, Copenhagen, Denmark.
World Health Organization (WHO). (2005). “WHO air quality guidelines global update.” Report on a working group meeting, Bonn, Germany.

Information & Authors

Information

Published In

Go to Journal of Performance of Constructed Facilities
Journal of Performance of Constructed Facilities
Volume 25Issue 4August 2011
Pages: 326 - 335

History

Received: Feb 24, 2010
Accepted: Aug 27, 2010
Published online: Jul 15, 2011
Published in print: Aug 1, 2011

Permissions

Request permissions for this article.

Authors

Affiliations

Consultant, Superasia Development Group. E-mail: [email protected]

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

Cited by

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share