Technical Papers
Feb 3, 2012

Flexural Performance and Moment Connection of Concrete-Filled GFRP Tube–Encased Steel I-Sections

Publication: Journal of Composites for Construction
Volume 16, Issue 5

Abstract

A hybrid system, concrete-filled fiber-reinforced polymer (FRP) tube (CFFT)-encased steel I-section, is introduced. The embedded steel section enhances flexural strength and stiffness, and provides a pseudoductile behavior. It also facilitates connection of the CFFT member to footings or other members. Phase I of the experimental program addresses the flexural behavior of the system through ten beam specimens, including steel and CFFT control specimens. The glass fiber-reinforced polymer (GFRP) tubes varied in thickness and laminate structure. The steel section enhanced performance considerably, especially pseudoductility, in tubes with cross-ply laminates, in which a significant sustained reserved strength remains stable over large deflections on fracture of the tube. CFFTs with angle-ply tubes showed a considerable inherent ductility on their own, in which case, adding the steel section enhanced strength and stiffness only. Phase II addresses a moment connection through five cantilever tests. The connections consist of steel base plates welded to the steel sections, which are embedded into the CFFT members at various length (Ls)-to-span-length (L) ratios ranging from 0.1 to 1.0. Three distinct failure modes are observed. At (Ls/L) ratios of up to 0.17, premature bond failure occurs. At ratios of 0.17 to 0.47, the CFFT member achieves flexural tension failure of the tube just beyond the free end of the steel section. Beyond a 0.47 ratio, the full plastic hinge capacity is developed at the fixed end. A simple design-oriented model that predicts strengths at the full range of (Ls/L) ratios is developed and validated.

Get full access to this article

View all available purchase options and get full access to this article.

References

Ahmad, I., Zhu, Z., Mirmiran, A., and Fam, A. (2005). “Shear strength prediction of deep CFFT beams.”, 1085–1102.
ASTM. (1995). “Standard test method for tensile properties of polymer matrix composite materials.”, West Conshohoken, PA.
ASTM. (1996). “Standard test method for compressive strength of cylindrical concrete specimens.”, West Conshohoken, PA.
ASTM. (2009). “Standard test methods for tension testing of metallic materials.”, West Conshohoken, PA.
Burgueno, R., Davol, A., and Seible, F. (1998). “The carbon shell system for modular bridge components.” Proc., 2nd Int. Conf. on Composites in Infrastructure (ICCI’98), Tucson, AZ, 341–354.
Cole, B., and Fam, A. (2006). “Flexural load testing of concrete-filled FRP tubes with longitudinal steel and FRP rebar.” J. Compos. Constr., 10(2), 161–171.
Fam, A., Greene, R., and Rizkalla, S. (2003a). “Field applications of concrete-filled FRP tubes for marine piles.”, 161–180.
Fam, A., and Mandal, S. (2006). “Prestressed concrete-filled fiber-reinforced polymer circular tubes tested in flexure.” PCI J., 51(4), 42–54.
Fam, A., Pando, M., Filz, G., and Rizkalla, S. (2003b). “Precast composite piles for the Route 40 bridge in Virginia using concrete-filled FRP tubes.” PCI J., 48(3), 32–45.
Fam, A. Z., and Rizkalla, S. H. (2002). “Flexural behaviour of concrete-filled fiber-reinforced polymer circular tubes.” J. Compos. Constr., 6(2), 123–132.
Fam, A., and Son, J. K. (2008). “Finite element modeling of hollow and concrete-filled fiber composite tubes in flexure: Part 2: Optimization of partial filling and a design method for poles.” Eng. Struct., 30(10), 2667–2676.
Helmi, K., Fam, A., Mufti, A., and Hall, M. (2006). “Effects of driving forces and bending fatigue on structural performance of a novel CFFT flexural pile.” Can. J. Civ. Eng., 33(6), 683–691.
Karimi, K., Tait, M. J., and El-Dakhakhni, W. W. (2011). “Influence of slenderness on the behavior of a FRP-encased steel-concrete composite column.” J. Compos. Constr., 16(1), 100–109.
Mirmiran, A., and Shahawy, M. (1997). “Behavior of concrete columns confined by fiber composites.” J. Struct. Eng., 123(5), 583–590.
Nelson, M., Lai, Y. C., and Fam, A. (2008). “Moment connection of concrete-filled fiber reinforced polymer tubes by direct embedment into footings.” Adv. Struct. Eng., 11(5), 537–547.
Park, R., and Paulay, T. (1975). Reinforced concrete structures, Wiley, New York.
Sadeghian, P., Lai, Y. C., and Fam, A. (2011). “Testing and modeling of a new moment connection of concrete-filled FRP tubes to footings under monotonic and cyclic loadings.” J. Compos. Constr., 15(4), 653–662.
Teng, J. G., Yu, T., Wong, Y. L., and Dong, S. L. (2007). “Hybrid FRP-concrete-steel tubular columns: Concept and behavior.” Constr. Build. Mater., 21(4), 846–854.
Xiao, Y., Zhang, Z., Hu, J., Kunnath, S., and Guo, P. (2011). “Seismic behavior of CFT column and steel pile footings.” J. Bridge Eng., 16(5), 575–586.
Zakaib, S. (2011). “Flexural performance and moment connections of concrete-filled FRP tubes (CFFTs) and CFFT-encased steel I sections.” Master’s thesis, Queen’s Univ., Kingston, ON, Canada.

Information & Authors

Information

Published In

Go to Journal of Composites for Construction
Journal of Composites for Construction
Volume 16Issue 5October 2012
Pages: 604 - 613

History

Received: Sep 29, 2011
Accepted: Jan 31, 2012
Published online: Feb 3, 2012
Published in print: Oct 1, 2012

Permissions

Request permissions for this article.

Authors

Affiliations

Sarah Zakaib [email protected]
Master’s Student, Dept. of Civil Engineering, Queen’s Univ., Kingston, ON, Canada (corresponding author). E-mail: [email protected]
Amir Fam
M.ASCE
Professor and Canada Research Chair in Innovative and Retrofitted Structures, Dept. of Civil Engineering, Queen’s Univ., Kingston, ON, Canada.

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

Cited by

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share