Analysis Model Verification of a Suspension Bridge Exploiting Configuration Survey and Field-Measured Data
Publication: Journal of Bridge Engineering
Volume 17, Issue 5
Abstract
The conformity between predicted and actual configurations of a suspension bridge is examined through a field survey with the compensation of temperature effects. The tension in the main cable is estimated from the surveyed configuration utilizing force equilibriums at the cable junction nodes. The measured hanger tensions and rigorous dead load information are also incorporated. The as-built configuration of the bridge shows fairly good agreement with the designed shape. The reproducibility of the dynamic properties is also examined for dominant vertical modes. The only tuning in the connection conditions of bearings produces natural frequencies that are in good agreement with the measured values.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This research was supported by a grant (05RCB05-01) from the Ministry of Land, Transport and Maritime of the Korean Government through the Korean Wind Engineering Research Center. The Facilities Management Authority at Busan Metropolitan City (BFMA), the owner of Gwangan Bridge, was in charge of the planning and performing of the field survey. The writers are very grateful for their cooperation, great concern, and active support.
References
Ahn, S. S. (1991). “Static and dynamic nonlinear analysis of spatial cable networks using elastic catenary cable element.” M.S. dissertation, Seoul National Univ., Seoul, South Korea.
Allemang, R. J., and Brown, D. L. (1982). “A correlation coefficient for modal vector analysis.” Proc., 1st Int. Modal Analysis Conf., Union College, Schenectady, NY, 110–116.
Berkooz, G., Holms, P., and Lumley, J. (1993). “The proper orthogonal decomposition in the analysis of turbulent flows.” Annu. Rev. Fluid Mech., 25, 539–575.
Brownjohn, J. M. W., Magalhães, F., Caetano, E., and Cunha, A. (2010). “Ambient vibration re-testing and operational modal analysis of the Humber Bridge.” Eng. Struct., 32(8), 2003–2018.
Chang, C. C., Chang, T. Y. P., and Zhang, Q. W. (2001). “Ambient vibration of long-span cable-stayed bridge.” J. Bridge Eng., 6(1), 46–53.
Chodai. (1997). “The design review of Gwangan Bridge superstructure.” Rep., Chodai, Tokyo, Japan (in Japanese).
Daniell, W. E., and Macdonald, J. H. G. (2007). “Improved finite element modelling of a cable-stayed bridge through systematic manual tuning.” Eng. Struct., 29(3), 358–371.
Dongah Construction (Dongah). (2000). “Request of re-review on stiffening truss weight of Gwangan Bridge.” Formal letter, Dongah, Seoul, South Korea (in Korean).
Facilities Management Authority at Busan Metropolitan City (BFMA). (2004). “A technical report for the tension measurement of hanger rope of Gwangan Bridge.” Rep., BFMA, Busan, South Korea (in Korean).
Facilities Management Authority at Busan Metropolitan City (BFMA). (2002). “The design report on the erection of stiffening truss of Gwangan Bridge.” Rep., BFMA, Busan, South Korea (in Korean).
Gentile, C., and Gallino, N. (2008). “Ambient vibration testing and structural evaluation of an historic suspension footbridge.” Adv. Eng. Software, 39(4), 356–366.
Gwangan Road Construction Authority at Busan Metropolitan City (BGCA). (1994). “The design report of Gwangan Bridge.” Rep., BGCA, Busan, South Korea (in Korean).
Karoumi, R. (1999). “Some modeling aspects in the nonlinear finite element analysis of cable supported bridges.” Comput. Struct., 71(4), 397–412.
Kim, K.-S., and Lee, H. S. (2001). “Analysis of target configurations under dead loads for cable-supported bridges.” Comput. Struct., 79(29-30), 2681–2692.
Kim, H.-K., Lee, M.-J., and Chang, S.-P. (2002). “Non-linear shape-finding analysis of a self-anchored suspension bridge.” Eng. Struct., 24(12), 1547–1559.
McGuire, W., Gallagher, R. H., and Ziemian, R. D. (2000). Matrix structural analysis, Wiley, New York.
MIDAS Information Technology (MIDAS IT). (1996). “Midas civil—integrated solution system for bridge and civil structures.” MIDAS Information Technology, Gyeonggi-do, South Korea.
Park, W., Kim, H.-K., and Park, J. (2012). “Finite element model updating for a cable-stayed bridge using manual tuning and sensitivity-based optimization.” Struct. Eng. Int., 22(1), 14–19.
Ren, W.-X., Blandford, G. E., and Harik, I. E. (2004). “Roebling suspension bridge. I: Finite-element model and free vibration response.” J. Bridge Eng., 9(2), 110–118.
Ren, W.-X., Lin, Y.-Q., and Peng, X.-L. (2007). “Field load tests and numerical analysis of qingzhou cable-stayed bridge.” J. Bridge Eng., 12(2), 261–270.
Siringoringo, D. M., and Fujino, Y. (2008). “System identification of suspension bridge from ambient vibration response.” Eng. Struct., 30(2), 462–477.
Yooshin Engineering Corporation (Yooshin). (2000). “Re-reviewed stiffening truss weight of Gwangan Bridge.” Formal letter, Yooshin, Seoul, South Korea (in Korean).
Zhang, Q. W., Chang, T. Y. P., and Chang, C. C. (2001). “Finite-element model updating for the Kap Shui Mun cable-stayed bridge.” J. Bridge Eng., 6(4), 285–293.
Information & Authors
Information
Published In
Copyright
© 2012 American Society of Civil Engineers.
History
Received: Mar 26, 2011
Accepted: Sep 16, 2011
Published online: Sep 19, 2011
Published in print: Sep 1, 2012
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.