Effect of a Secondary Building Envelope on Cooling Loads in Hot Climates
Publication: Journal of Architectural Engineering
Volume 28, Issue 2
Abstract
Cooling buildings represent a major environmental issue, especially during summers. Although thermal insulation can decrease cooling loads, the presence of thermal bridges, infiltrations, windows, and other openings pose a continuous challenge. In the Middle East and North Africa (MENA) region, for instance, most windows are made of aluminum, a thermal conductor. This paper uses two methods to evaluate the alternative solution of enveloping buildings, including windows, with a secondary layer. The first method involved small-scale models; two test rooms were built, with one (the reference room) being based on regular municipal thermal guidelines and the other (the enveloped room) including an extra, secondary surrounding layer. The second test staged a similar scenario via software simulation. Both sets of results showed a significant reduction in electricity consumption in the enveloped room, which became more notable as the weather grew hotter. At the high end of the temperature scale, the power consumption of the enveloped room was 47%–54% lower than that of the reference room. However, such a secondary building envelope would increase the width of the wall structure and present the downside of adding to construction costs. While adopting this system in Dubai may save the city an estimated 16.6% in electrical energy, based on current prices, a house would likely need between 10 and 15 years to recuperate the associated capital investment.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The authors extend their appreciation to Ms. Foutoun Daboul, Ms. Shafiyah Rizwan, Mr. Basel Al Afandi, and Ms. Fairuz Al Moghrabi for their help in collecting the data and preparing this document. The authors also express their gratitude to Ajman University for its generous support toward publishing this paper. This research was funded by Ajman University.
References
ASHRAE. 2010. Standard 55-2010, thermal environmental conditions for human occupancy. ASHRAE 55-2017. Atlanta: ASHRAE.
Baba, F., and H. Ge. 2016. “Dynamic effect of thermal bridges on the energy performance of residential buildings in BC.” In Vol. 8 of Proc., Int. Building Performance Simulation Association Congress. Red Hook, NY: Curran Associates, Inc.
Brugnaro, G., M. Caini, and R. Paparella. n.d. “Energy Saving through Building Envelope Innovation: Smart Skin Design. Wseas.Us.” Accessed July 5, 2021. http://www.dicea.unipd.it.
Daouas, N., Z. Hassen, H. B. Aissia. n.d. “Analytical periodic solution for the study of thermal performance and optimum insulation thickness of building walls in Tunisia.” Appl. Therm. Eng. 30 (4): 319–326. https://doi.org/10.1016/j.applthermaleng.2009.09.009.
Del Barrio, E. P. 1998. “Analysis of the green roofs cooling potential in buildings.” Energy Build. 27 (2): 179–193. https://doi.org/10.1016/S0378-7788(97)00029-7.
DEWA (Dubai Electricity & Water Authority). 2010. “Green building regulations.” Accessed March 17, 2019. http://www.dewa.gov.ae/images/gb/greenbuilding2010e.pdf.
DEWA (Dubai Electricity & Water Authority). 2018. “Tariff calculator.” Accessed March 17, 2019. https://www.dewa.gov.ae/en/about-dewa/about-us/dewa-publications/annual-statistics.
DEWA (Dubai Electricity & Water Authority). n.d.-a “DEWA bills in Dubai—Water and electricity cost.” Accessed July 27, 2021. https://www.guide2dubai.com/living/expat-life/dewa-utility-bills.
DEWA (Dubai Electricity & Water Authority). n.d.-b “24 Degrees Campaign.” Accessed January 27, 2019. https://www.dewa.gov.ae/en/customer/sustainability/spread-the-message/24-degrees-campaign.
Dubai Municipality, Dubai Central Laboratories (DCL), Research and Standardization Management Office. 2018. “Thermal transmittance (U) value calculation of Mancon Block Factory.” Dubai.
Dubai Municipality Building Code. n.d. Accessed February 3, 2019. https://www.google.com/search?q=dubai+municipality+building+code&rlz=1C1AZAA_enAE741AE741&oq=dubai+municipality+building+code&aqs=chrome.69i57j0l5.7311j0j1&sourceid=chrome&ie=UTF-8.
Huang, Y., J. L. Niu, and T. M. Chung. 2014. “Comprehensive analysis on thermal and daylighting performance of glazing and shading designs on office building envelope in cooling-dominant climates.” Appl. Energy 134: 215–228. https://doi.org/10.1016/J.APENERGY.2014.07.100.
Kennedy, E., D. Fecheyr-Lippens, B.-K. Hsiung, P. H. Niewiarowski, and M. Kolodziej. 2015. “Biomimicry: A path to sustainable innovation.” Des. Issues 31 (3): 66–73. https://doi.org/10.1162/DESI_A_00339.
Kirkegaard, P H, and I W Foged. 2011. “Development and evaluation of a responsive building envelope.” Building Centre. Accessed July 5, 2018. https://vbn.aau.dk/en/publications/development-and-evaluation-of-a-responsive-building-envelope.
Kralj, A., M. Drev, M. Žnidaršič, B. Černe, J. Hafner, and B. P. Jelle. 2019. “Investigations of 6-pane glazing: Properties and possibilities.” Energy Build. 190: 61–68. https://doi.org/10.1016/J.ENBUILD.2019.02.033.
Langdon, D. n.d. “Middle east property and construction handbook–2010/2011.” Accessed July 27, 2021. https://scholar.google.com/scholar?hl=en&as_sdt=0%2C5&q=Langdon+D.+Middle+East+property+and+construction+handbook-2010%2F2011&btnG=#d=gs_cit&u=%2Fscholar%3Fq%3Dinfo%3A33k1z4yJ8CAJ%3Ascholar.google.com%2F%26output%3Dcite%26scirp%3D1%26hl%3Den.
Lorente, S., and A. Bejan. 2002. “Combined ‘flow and strength’ geometric optimization: Internal structure in a vertical insulating wall with air cavities and prescribed strength.” Int. J. Heat Mass Transfer 45 (16): 3313–20. https://doi.org/10.1016/S0017-9310(02)00052-2.
Martinez, R. G. 2017. “Highly insulated systems for energy retrofitting of façades on its interior.” Procedia Environ. Sci. 38: 3–10. https://doi.org/10.1016/j.proenv.2017.03.065.
Ministry of Presidential Affairs—National Center of Meteorology. n.d. Accessed February 18, 2019. http://www.ncm.ae/en#!/Radar_Merge_Sat/26.
Powerwise. n.d. “Air conditioning.” Accessed January 27, 2019. http://www.powerwise.gov.ae/en/section/how-can-i-save-electricity/residential/air-conditioning.
Shameri, M. A., M. A. Alghoul, K. Sopian, M. Fauzi, M. Zain, and O. Elayeb. 2011. “Perspectives of double skin façade systems in buildings and energy saving.” Renew. Sustainable Energy Rev. 15 (3): 1468–75. https://doi.org/10.1016/J.RSER.2010.10.016.
Verbeke, S., and A. Audenaert. 2018. “Thermal inertia in buildings: A review of impacts across climate and building use.” Renew. Sustainable Energy Rev. 82: 2300–2318. https://doi.org/10.1016/J.RSER.2017.08.083.
WBDG (Whole Building Design Guide). n.d. “Building envelope design guide—Introduction.” Accessed July 27, 2021. https://www.wbdg.org/guides-specifications/building-envelope-design-guide/building-envelope-design-guide-introduction.
Weather Data by Region. n.d. “EnergyPlus.” Accessed July 27, 2021. https://energyplus.net/weather-region/asia_wmo_region_2/ARE.
WBDG (Whole Building Design Guide). 2017. “Windows and glazing.” Accessed March 1, 2019. https://www.wbdg.org/resources/windows-and-glazing.
Yang, L., H. Yan, and J. C. Lam. 2014. “Thermal comfort and building energy consumption implications —A review.” Appl. Energy 115: 164–73. https://doi.org/10.1016/j.apenergy.2013.10.062.
Information & Authors
Information
Published In
Copyright
© 2022 American Society of Civil Engineers.
History
Received: Aug 18, 2021
Accepted: Dec 28, 2021
Published online: Mar 2, 2022
Published in print: Jun 1, 2022
Discussion open until: Aug 2, 2022
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.
Cited by
- Ayat Elkhazindar, Sahar N. Kharrufa, Mohammad S. Arar, The Effect of Urban Form on the Heat Island Phenomenon and Human Thermal Comfort: A Comparative Study of UAE Residential Sites, Energies, 10.3390/en15155471, 15, 15, (5471), (2022).