Feasibility Study of Determination of Seismic Performance Factors for Structural Insulated Panels
Publication: Journal of Architectural Engineering
Volume 21, Issue 2
Abstract
The authors present the results of a feasibility study to apply the major steps of the methodology to quantify seismic performance factors (SPFs) for structural insulated panels (SIPs) as the seismic force–resisting system for residential and light commercial buildings. This methodology uses collapse evaluation to determine acceptable SPFs. Structural response prediction was assessed through the combination of building code seismic provisions, nonlinear dynamic analyses, and risk-based assessment techniques. The SIP system in this study consisted of a rigid foam insulation core sandwiched between two sheets of oriented strand board. Analytical modeling was carried out using seismic analysis software. The results of the preliminary study show that the methodology and the seismic analysis software used in this study can lead to the determination of SPFs for SIP systems, but extensive experimental test results among other data are needed for a comprehensive project to quantify SPFs.
Get full access to this article
View all available purchase options and get full access to this article.
References
ASCE. (2006). “Minimum design loads for buildings and other structures.” ASCE/SEI 7-05, Reston, VA.
ASTM. (2006). “Standard practice for static load test for shear resistance of framed walls for buildings.” E564-06, West Conshohocken, PA.
ASTM. (2009). “Standard test methods for cyclic (reversed) load test for shear resistance of vertical elements of the lateral force resisting systems for buildings.” E2126-09, West Conshohocken, PA.
Ayoub, A. (2007). “Seismic analysis of wood building structures.” Eng. Struct., 29(2), 213–223.
Black, G. O. (2009). “Development and application of an empirical loss analysis for woodframe buildings subject to seismic events.” Master’s thesis, Univ. of Delaware, Newark, DE.
Deierlein, G. G., Liel, A. B., Haselton, C. B., and Kircher, C. A. (2008). “ATC 63 methodology for evaluating seismic collapse safety of archetype buildings.” Proc., Structures Congress 2008: Crossing Borders, D. Anderson, C. Ventura, D. Harvey, and M. Hoit, eds., ASCE, Reston, VA, 1–10.
Donovan, L. T., and Memari, A. M. (2011). “Determination of seismic performance factors for structural insulated panel shear walls based on FEMA P695 methodology.” PHRC Research Series Rep. No. 110, Pennsylvania Housing Research Center (PHRC), University Park, PA.
Federation of American Scientists (FAS). (2010). “Analysis of the seismic performance of SIPs: A white paper.” 〈http://fas.org/programs/energy/btech/advanced%20technologies/sip_testing.html〉 (Jan. 15, 2010).
FEMA. (2004a). “NEHRP recommended provisions for seismic regulations for new buildings and other structures. Part 1: Provisions.” FEMA 450-1, 2003 Ed., Washington, DC.
FEMA. (2004b). “NEHRP recommended provisions for seismic regulations for new buildings and other structures. Part 2: Commentary.” FEMA 450-2, 2003 Ed., Washington, DC.
FEMA. (2009). “Quantification of building seismic performance factors.” FEMA P695, Washington, DC.
Folz, B., and Filiatrault, A. (2001). “Cyclic analysis of wood shear walls.” J. Struct. Eng., 433–441.
Folz, B., and Filiatrault, A. (2004a). “Seismic analysis of woodframe structures. I: Model formulation.” J. Struct. Eng., 1353–1360.
Folz, B., and Filiatrault, A. (2004b). “Seismic analysis of woodframe structures. II: Model implementation and verification.” J. Struct. Eng., 1361–1370.
International Code Council (ICC). (2006a). International building code, Country Club Hills, IL.
International Code Council (ICC). (2006b). International residential code for one- and two-family dwellings, Country Club Hills, IL.
International Code Council (ICC). (2009). “Acceptance criteria for prefabricated wood shear panels.” AC130, ICC Evaluation Service (ICC-ES), Whittier, CA.
Jamison, J. B. (1997). “Monotonic and cyclic performance of structurally insulated panel shear walls.” M.S. thesis, Virginia Polytechnic Institute and State Univ., Blacksburg, VA.
Krawinkler, H., Parisi, F., Ibarra, L., Ayoub, A., and Medina, R. (2001). “Development of a testing protocol for woodframe structures.” CUREE-Caltech Woodframe Project Rep. No. W-02, Stanford Univ., Stanford, CA.
Mosalam, K. M., Hagerman, J., and Kelly, H. (2008). “Seismic evaluation of structural insulated panels.” Proc., 5th Int. Engineering and Construction Conf. (IECC’5), ASCE, Reston, VA.
Network for Earthquake Engineering Simulation (NEES). (2005). “Development of a performance-based seismic design philosophy for mid-rise wood-frame construction.” NEESWood, 〈http://nees.buffalo.edu/projects/NEESWood〉 (Dec. 21, 2011).
Pacific Earthquake Engineering Research Center (PEER). (2006). “PEER NGA database.” 〈http://peer.berkeley.edu/nga/〉 (Dec. 21, 2011).
Pang, W., Rosowsky, D. V., Pei, S., and van de Lindt, J. W. (2010). “Simplified direct displacement design of six-story woodframe building and pretest seismic performance assessment.” J. Struct. Eng., 813–825.
Pei, S., and van de Lindt, J. W. (2007). User’s manual for SAPWood for Windows: Seismic analysis package for woodframe structures, Colorado State Univ., Fort Collins, CO.
SAPWood [Computer software]. Fort Collins, CO, Colorado State Univ.
Terentiuk, S., and Memari, A. M. (2011). “Performance of structural insulated panels with different fasteners and splines under monotonic and cyclic loading.” PHRC Research Series Rep. No. 109, Pennsylvania Housing Research Center (PHRC), University Park, PA.
Terentiuk, S., and Memari, A. M. (2012). “In-plane monotonic and cyclic racking load testing of structural insulated panels.” J. Archit. Eng., 261–275.
Vamvatsikos, D., and Cornell, C. A. (2002). “Incremental dynamic analysis.” Earthquake Eng. Struct. Dynam., 31(3), 491–514.
Information & Authors
Information
Published In
Copyright
© 2014 American Society of Civil Engineers.
History
Received: Aug 20, 2013
Accepted: Sep 22, 2014
Published online: Oct 30, 2014
Published in print: Jun 1, 2015
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.