Abstract
This paper addresses practical applications of the type curve method and modified linear curve fitting method described in a companion paper for evaluating the hydraulic conductivity of a vertical cutoff wall. Sensitivity analyses were performed for factors that might influence results from a slug test in a vertical cutoff wall. The factors considered are (1) width of the vertical cutoff wall, (2) eccentricity of a well location, (3) well aspect ratio, and (4) distance from the upper and lower boundaries of the wall to a well intake and discharge section. In addition, the effects of variable hydraulic properties—hydraulic conductivity and specific storage —on the results of a slug test are evaluated. Also, the effect of initial slug size and difference between a rising and falling head slug test are investigated in connection with the variability of the hydraulic properties. Analyses show that the compressibility of the porous medium has a dominant effect. Various errors can arise from the simplifying assumptions used in slug test analysis, but these errors often tend to offset one another. Performing sequential slug tests can yield progressively lower hydraulic conductivity as a result of consolidation of the barrier wall material.
Get full access to this article
View all available purchase options and get full access to this article.
References
Bouwer, H., and Rice, R. C. (1976). “A slug test for determining hydraulic conductivity of unconfined aquifer with completely or partially penetrating wells.” Water Resour. Res., 12(3), 423–428.
Britton, J. P., Filz, G. M., and Little, J. C. (2002). “Shape factors for single-well tests in soil-bentonite cutoff walls.” Proc., 4th Int. Congress on Environmental Geotechnics, de Mello and Almeida, eds., 639–644.
Chirlin, G. R. (1991). “Type curve for a slug test in an infinitely or semi-infinitely thick aquifer.” Proc., Int. Symp. on Ground Water, 169–174.
Choi, H. (2002). “Analysis of slug tests to determine hydraulic conductivity of vertical cutoff walls.” Ph.D. thesis, Univ. of Illinois, Urbana-Champaign, Ill.
Choi, H., and Daniel, D. E. (2006). “Slug test analysis in vertical cutoff walls. I: Analysis methods.” J. Geotech. Geoenviron. Eng. 132(4), 429–438.
Daniel, D. E., and Choi, H. (1999). “Hydraulic conductivity evaluation of vertical barrier walls.” Geo-engineering for underground facilities, G. Fernandez and R. A. Bauer, eds., ASCE, Reston, Va., 140–161.
D’Appolonia, D. J. (1980). “Soil-bentonite slurry trench cutoffs.” J. Geotech. Eng. Div., Am. Soc. Civ. Eng., 106(4), 399–417.
EMCON. (1995). M-11/15, M-17/21, and M-26/E-29 slurry walls post-construction performance evaluation, West Contra Costa Sanitary Landfill, Richmond, Calif.
Evans, J. C., and Cooley, B. (1993). “Slurry wall performance.” Progress in geotechnical engineering, Hershey, Pa.
Filz, G. M., Boyer, R. D., and Davidson, R. R. (1997). “Bentonite-water slurry rheology and cutoff wall trench stability.” In situ remediation of the geoenvironment, J. C. Evans, ed., ASCE, Reston, Va., 139–153.
Filz, G. M., Henry, L. B., Heslin, G. M., and Davidson, R. R. (2001). “Determining hydraulic conductivity of soil-bentonite using the API filter press.” Geotech. Test. J., 24(1), 61–71.
Freeze, R. A., and Cherry, J. A. (1979). Groundwater, Prentice-Hall, Englewood Cliffs, N.J.
Henry, L. B., Filz, G. M., and Davidson, R. R. (1998). “Formation and properties of bentonite filter cakes.” Filtration and drainage in geotechnical/geoenvironmental engineering, L. N. Reddi and M. V. S. Bonalo, eds., ASCE, Reston, Va., 69–88.
Hvorslev, M. J. (1951). “Time lag and soil permeability in ground-water observation.” Bulletin No. 36, Waterways Experiment Station, United States Army Corps of Engineers, Vicksburg, Miss.
Hyder, Z. (1994). “Analysis of slug tests in partially penetrating wells.” Ph.D. thesis, Univ. of Kansas, Lawrence, Ks.
Hyder, Z., Butler, J. J., McElwee, C. D., and Liu, W. (1994). “Slug tests in partially penetrating wells.” Water Resour. Res., 30(11), 2945–2957.
Khoury, M. A., Fayad, P. H., and Ladd, R. S. (1992). “Design, construction and performance of a soil-bentonite cutoff wall constructed in two stages.” Slurry wall: Design, construction, and quality control, STP 1129, ASTM, Philadelphia, 289–308.
McCandless, R. M., and Bodocsi, A. (1987). “Investigation of slurry cutoff wall design and construction methods for containing hazardous wastes.” EPA 600-S2-87/063, Environmental Protection Agency, Cincinnati.
Mesri, G., and Rokhsar, A. (1974). “Theory of consolidation for clays.” J. Geotech. Eng. Div., Am. Soc. Civ. Eng., 100(8), 889–904.
Rumer, R. R., and Mitchell, J. K. (1995). Assessment of barrier containment technologies, United States Department of Energy, United States Environmental Protection Agency, and DuPont Company.
Teeter, R. M., and Clemence, S. P. (1986). “In-place permeability measurement of slurry trench cutoff wall.” Proc., In Situ’ 86, Use of In Situ Tests in Geotechnical Engineering, Geotechnical Special Publication No. 6, 1049–1061.
Terzaghi, K. (1945). “Stability and stiffness of cellular cofferdams.” Trans. Am. Soc. Civ. Eng., 110, 1083–1119.
Terzaghi, K., Peck, R. B., and Mesri, G. (1996). Soil mechanics in engineering practice, 3rd Ed., Wiley, New York.
Yang, D. S., Luscher, U., Kimoto, I., and Takeshima, S. (1993). “SMW wall for seepage control in levee reconstruction.” Proc., 3rd Int. Conf. on Case Histories in Geotechnical Engineering, 487–492.
Information & Authors
Information
Published In
Copyright
© 2006 ASCE.
History
Received: May 13, 2003
Accepted: Apr 11, 2005
Published online: Apr 1, 2006
Published in print: Apr 2006
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.