In Situ Load Testing of Parking Garage Reinforced Concrete Slabs: Comparison between 24 h and Cyclic Load Testing
Publication: Practice Periodical on Structural Design and Construction
Volume 10, Issue 1
Abstract
This paper reports on the results obtained on the applicability of the diagnostic cyclic load test method in comparison with the existing test procedure adopted in ACI-318. A parking garage, owned by St. Louis County, St. Louis, Missouri, scheduled for demolition during the summer of 2002 was used as a research test bed before demolition. This structure, a two-story steel and reinforced concrete (RC) frame with one-way RC slabs built in 1970’s, was ideal, in terms of size and construction system, for performing comparative field experimentation on load testing. Investigation and validity of acceptance criteria of existing and proposed testing methods were performed. Two identical RC slabs were tested, according to both the standard procedure (ACI-318-02) and the proposed diagnostic load testing. In both instances, the applied total test load was such that the slab did not pass the load test. This allowed characterizing the critical test parameters that govern acceptability and draw conclusions on their values. After load testing, both slabs were loaded until partial collapse was reached. This allowed making observations on the margin of safety with respect to collapse, a determination that is not generally possible in a proof test. The analysis of the experimental data provides professionals with evidence on the validity of in situ assessment for the adequacy of structural members.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgements
The writers acknowledge the financial support from the National Science Foundation Industry/University Cooperative Research Center at the Univ. of Missouri-Rolla and thank the St. Louis County for providing the opportunity for the testing of the structure.
References
American Concrete Institute (ACI). (2002). “Building code requirements for structural concrete and commentary.” ACI 318R-02, Farmington Hills, Mich.
Bick, R. R. (1998). “Ocean Vista power generation station turbine deck rehabilitation project.” 1998 International Concrete Repair Institute Award for Outstanding Concrete Repair Recipient, Southern California Edison, 26.
Bungey, J. H. (1989). The testing of concrete in structures, 2nd Ed., Chapman and Hall, New York.
Concrete Innovation Appraisal Service (CIAS). (2001). “Guidelines for the rapid load testing of concrete structural members.” CIAS Rep. No. 00-1, ACI International, Farmington Hills, Mich.
FitzSimons, N., and Longinow, A. (1975). “Guidance for load tests of buildings” J. Struct. Div. ASCE, 101(7), 1367–1380.
Fling, R. S., McCrate, T. E., and Doncaster, C. W. (1989). Load test compared to earlier structure failure, Concrete International, American Concrete Institute, Vol. 18, No. 11, 22–27.
Gold, W. J., and Nanni, A. (1998). “In situ load testing to evaluate new repair techniques.” Proc., NIST Workshop on Standards Development for the Use of Fiber Reinforced Polymers for the Rehabilitation of Concrete and Masonry Structures, National Institute of Standards and Technology, Gaithersburg, Md., 102–112.
Hall, W. B., and Tsai, M. (1989). “Load testing, structural reliability and test evaluation.” Structural safety, Elsevier Science, New York, Vol. 6, 285–302.
Hogue, T., Conforth, R. C., and Nanni, A. (1999). “Myriad convention center floor system: Issues and needs.” Proc., 4th Int. Symp. on FRP for Reinforcement of Concrete Structures (FRPRCS4).
MacGregor, J. G. (1997). “Reinforced concrete: Mechanics and design.” 3rd Ed., Prentice–Hall, Englewood, N.J.
Mettemeyer, M. (1999). “In situ rapid load testing of concrete structures.” MS thesis, Dept. of Civil Engineering, Univ. of Missouri-Rolla, Rolla, Mo.
Nanni, A., and Gold, W. J. (1998). “Evaluating CFRP strengthening systems in situ.” Concrete Repair Bull., International Concrete Repair Institute, 11(1), 12–14.
Nanni, A., and Mettemeyer, M. (2001). “Diagnostic load testing of a two-way postensioned concrete slab.” Pract. Period. Struct. Des. Constr. 6(2), 73–82.
RILEM Technical Committee 20-TBS. (1984). “General recommendation for static loading test of load-bearing concrete structures in situ (TBS2).” RILEM Technical Recommendations for the Testing and Use of Construction Materials, E & FN Spon, London, 379–385.
Information & Authors
Information
Published In
Copyright
© 2004 ASCE.
History
Received: Sep 1, 2003
Accepted: Dec 2, 2003
Published online: Feb 1, 2005
Published in print: Feb 2005
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.