TECHNICAL PAPERS
Nov 14, 2003

Economizer Application in Dual-Duct Air-Handling Units

Publication: Journal of Architectural Engineering
Volume 9, Issue 4

Abstract

Economizers modulate outside air intake to minimize/eliminate mechanical cooling in air-handling units when outside air enthalpy is lower than the return air enthalpy. A theoretical study is conducted to developed analytical economizer models, to investigate potential energy savings, and to develop a potential energy savings calculation method for dual-duct air-handling unit systems. The study found that economizers decrease cooling energy consumption without heating energy penalties for dual-fan, dual-duct air-handling units. Economizers have significant heating energy penalties for single-fan, dual-duct air-handling units.

Get full access to this article

View all available purchase options and get full access to this article.

References

Alley, R. L. (1988). “Selecting and sizing outside and return air damper for VAV economizer systems.” ASHRAE Trans., 94, Part 1.
Avery, G. (1996). “Selecting and controlling economizer dampers.” Heat./Piping/Air Cond., 68.
Brandemuehl, M. J., and Braun, J. E. (1999). “The impact of demand-controlled and economizer ventilation strategies on energy use in buildings.” ASHRAE Trans., 105, Part 2.
Catanese, D. L. (1991). “An energy analysis of low-temperature air distribution systems and reduced economizer-cycle cooling.” ASHRAE Trans., 97, Part 1.
Degelman, L. (1984). “Bin weather data.” American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta.
Joo, I., and Liu, M. (2002). “Performance analysis of dual-fan, dual-duct constant volume air-handling units.” ASHRAE Trans., 108, Part 2.
Liu, M., Claridge, D. E., and Park, B. Y. (1997). “An advanced econo-mizer controller for dual-duct air-handling systems—With a case application.” ASHRAE Trans., 103, Part 2.
Mumma, S. A., and Wong, Y. M. (1990). “Analytical evaluation of outdoor airflow variation vs. supply airflow rate variation invariable-air-volume systems when the outdoor air damper position is fixed.” ASHRAE Trans., 103, Part 2.
Park, C. K., Kelly, G. E., and Kao, J. Y. (1984). “Economizer algorithms for energy management and control systems.” NBSIR 84-2832, National Bureau of Standards, Gaithersburg, Md.
Parken, W. H., Kao, J. Y., and Kelly, G. E. (1982). “Strategies for energy conservation in small office buildings.” NBSIR 84-2489, National Bureau of Standards, Gaithersburg, Md. (now NIST).
Rock, B. A., and Wu, C. T. (1998). “Performance of fixed, air-side economizer, and neural network demand-controlled ventilation in CAV systems.” ASHRAE Trans., 104, Part 2.
Taylor, S. T. (2000). “Comparing economizer relief systems.” ASHRAE J., 42.
Tom, S. T., and Hawks, K. H. (1987). “Demand-controlled economizers.” ASHRAE Trans., 93, Part 1.
Wacker, P. C. (1989). “Economizer savings study.” ASHRAE Trans., 95, Part 1.
Zmeureanu, R. (1989). “A case study of energy savings due to the economizer system in Montreal.” Energy (Oxford), 14(9).

Information & Authors

Information

Published In

Go to Journal of Architectural Engineering
Journal of Architectural Engineering
Volume 9Issue 4December 2003
Pages: 126 - 133

History

Received: Nov 6, 2002
Accepted: Mar 25, 2003
Published online: Nov 14, 2003
Published in print: Dec 2003

Permissions

Request permissions for this article.

Authors

Affiliations

Ik-Seong Joo
Graduate Student, Univ. of Nebraska–Lincoln, 243 PKI, 1110 S 67th St., Omaha, NE 68182.
Mingsheng Liu, P.E.
Associate Professor, Univ. of Nebraska–Lincoln, 206C PKI, 1110 S 67th St., Omaha, NE 68182.

Metrics & Citations

Metrics

Citations

Download citation

If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.

Cited by

View Options

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Get Access

Access content

Please select your options to get access

Log in/Register Log in via your institution (Shibboleth)
ASCE Members: Please log in to see member pricing

Purchase

Save for later Information on ASCE Library Cards
ASCE Library Cards let you download journal articles, proceedings papers, and available book chapters across the entire ASCE Library platform. ASCE Library Cards remain active for 24 months or until all downloads are used. Note: This content will be debited as one download at time of checkout.

Terms of Use: ASCE Library Cards are for individual, personal use only. Reselling, republishing, or forwarding the materials to libraries or reading rooms is prohibited.
ASCE Library Card (5 downloads)
$105.00
Add to cart
ASCE Library Card (20 downloads)
$280.00
Add to cart
Buy Single Article
$35.00
Add to cart

Media

Figures

Other

Tables

Share

Share

Copy the content Link

Share with email

Email a colleague

Share