Thermal Performance of an Interlocking Fiber-Reinforced Plastic Building Envelope System
Publication: Journal of Architectural Engineering
Volume 3, Issue 1
Abstract
Fiber-reinforced plastic (FRP) materials are being more frequently used in building construction. Recently, a newly developed concept consisting of a tongue-and-groove fiberglass composite panel system has been developed for use in the construction of building envelope systems. Since little information is available on the thermal characteristics of such panel systems, a testing program was developed to investigate the thermal characteristics of panels that are commercially available at the present. Two full-scale 1.22 m × 1.22 m (4 ft × 4 ft) FRP panels were tested. Two panel thicknesses were considered: 25 mm (1 in.) and 76 mm (3 in.). A calibrated temperature-controlled test plate was used with heat-flow sensors to determine the thermal resistance of the FRP panels at the midsections of panels and at the interfaces (i.e., joints) between two adjoining panels. Two conditions were simulated: “dry joint,” which includes only mechanical interlocking at the joints, and “sealed joint,” in which the joints were sealed with a commercially available sealant. The R-values of the tested panels were approximately 5–46% higher in the sealed-joint condition. Sealed joints decrease heat exchange across the envelope system, thereby increasing the thermal resistance values of the panel system. The relatively high R-value of the 76 mm (3 in.) panel system {2.0 (m2 K)/W [11.36 (h ft2°F)/Btu]} is encouraging, and the possibilities of using the panels in building construction should further be explored.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Abdou, O., and Murali, K. (1994). “The effect of air cells and mortar joints on the thermal resistance of concrete masonry walls.”Energy and Buildings, (21), 111–119.
2.
Heat transmission coefficients for walls, roofs, ceilings, and floors. (1993). Am. Soc. of Heating, Refrigerating and Air-Conditioning Engrs., Inc.
3.
Larson, D. C. (1985). “Thermal resistance measurements with heat flow sensors—application to spray-applied insulation systems.”Building applications of heat flux transducers, ASTM STP 885, E. Bales, M. Bomberg, and G. E. Courville, eds., ASTM, West Conshohocken, Pa., 129–139.
4.
Larson, D. C., and Corneliussen, R. D. (1983). “Thermal testing of roof systems.”Thermal insulation, materials, and systems for energy conservation in the '80s, ASTM STP 789, F. A. Govan, D. M. Greason, and J. D. McAllister, eds., ASTM, West Conshohocken, Pa., 400–412.
5.
Powell, F. J. (1983). “Guarded hot-plate measurements.” Nat. Bureau of Standards, Washington, D.C.
Information & Authors
Information
Published In
Copyright
Copyright © 1997 American Society of Civil Engineers.
History
Published online: Mar 1, 1997
Published in print: Mar 1997
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.