Size Effect in Normal- and High-Strength Concrete with Different Notches under the Axial Load
Publication: Journal of Materials in Civil Engineering
Volume 21, Issue 9
Abstract
This study investigated the fracturing of concrete under triaxial compression. The experimental program involved size effect tests of compression fractures of cylindrical specimens with small notches, large notches, and holes. The geometrically similar columns of large , medium , and small slenderness using a size range of 1:2:4:8 (8 for only medium slenderness) were tested. The study’s columns were built of normal- and high-strength concrete, in which the maximum aggregate size was 10 mm. A strong size effect was observed in the results. It is shown that, with increasing strength, the size effect becomes more pronounced as the brittleness is increased.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
Partial support for the experiments was received from Gazi University (Grant No. UNSPECIFIED06/2004–20) and the visiting scholar appointment of the second writer at Northwestern University was partially supported by the Fulbright Foundation. Both are gratefully acknowledged. The writers also thank Associate Professor, Dr. Ferhun Cem Caner for valuable help in this paper.
References
Abusiaf, H. F., Şener, S., and Barr, B. I. G. (1996). “Size effect tests in plain and reinforced columns.” Internal Rep. No. 1, Univ. of Wales, Cardiff.
Barr, B. I. G., Abusiaf, H. F., and Şener, S. (1998). “Size effect and fracture energy studies using compact compression specimens.” Mater. Struct., 31(1), 36–41.
Bazant, Z. P. (1990). “Size effect method for determining fracture energy and process zone of concrete.” Mater. Struct., 23(6), 461–465.
Bazant, Z. P. (2005). Scaling of structural strength, Elsevier, New York, Oxford.
Bazant, Z. P., and Planas, J. (1998). Fracture and size effect in concrete and other quasibrittle materials, CRC, Boca Raton, Boston.
Bazant, Z. P., and Şener, S. (1988). “Size effect in pullout tests.” ACI Mater. J., 85(5), 347–351.
Belgin, Ç., and Şener, S. (2001). “Size effect of notched circular concrete columns.” Proc., Meeting Laboratories Struc. Mech., The Scientific and Technical Research Council of Turkey, Ankara, 115–118 (in Turkish).
Belgin, Ç., and Şener, S. (2008). “Size effect on failure of overreinforced concrete beams.” Eng. Fract. Mech., 75, 2308–2319.
Hillerborg, K. (1985). “The theoretical basis of a method to determine the fracture energy of concrete.” Mater. Struct., 18(4), 291–296.
Jansen, D. C., and Shah, S. P. (1997). “Effect of length on compressive strain softening of concrete.” J. Eng. Mech., 123(1), 25–35.
Koç, V. (2005). “Size effect on normal and high strength concrete element in compression failure.” Ph.D. thesis, Gazi Univ., Ankara (in Turkish).
Şener, S. (1997). “Size effect test of high strength concrete.” J. Mater. Civ. Eng., 9(1), 46–48.
Şener, S., Barr, B. I. G., and Abusiaf, H. F. (1999a). “Size effect tests in unreinforced concrete columns.” Mag. Concrete Res., 51(1), 3–11.
Şener, S., Barr, B. I. G., and Abusiaf, H. F. (2004). “Size effect in axially loaded reinforced concrete columns.” J. Struct. Eng., 130(4), 662–670.
Şener, S., Bazant, Z. P., and Giraudon, E. B. (1999b). “Size effect on failure of bond splices of steel bars in concrete beams.” J. Struct. Eng., 125(6), 653–660.
van Mier, J. G. M., et al. (1997). “Strain-softening of concrete in uniaxial compression.” Mater. Struct., 30(4), 195–209.
Information & Authors
Information
Published In
Copyright
© 2009 ASCE.
History
Received: Apr 10, 2006
Accepted: Mar 26, 2009
Published online: Aug 14, 2009
Published in print: Sep 2009
Notes
Note. Associate Editor: Kolluru V. Subramanian
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.