Abstract
This paper discusses the interpretation of electrical conductivity measurements in concrete to assess water penetration. Specifically, a series of finite element simulations were performed to develop an analytical function that relates the measured electrical conductivity to the position of the moisture front inside a concrete specimen. The effects of specimen size and electrode location were considered in the simulations. An approach is demonstrated whereby the measured conductivity was used to determine the position of the moisture front after rewetting thereby enabling the sorption properties of the cover concrete to be evaluated. The method described in this paper improves on previous approaches in that it enables resolving the position of moisture front based on only one electrical measurement and properties of the saturated and unsaturated concrete. This allows the use of one electrode pair to detect the position of moisture front at any time a measurement is performed.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers gratefully acknowledge the support received from the National Science Foundation (NSF) under Grant No. NSF0134272: a Career Award granted to the second writer. Any opinions, findings and conclusions or recommendations expressed in this material are those of the writers and do not necessarily reflect the views of the National Science Foundation. The writers also gratefully acknowledge the support received from the Center for Advanced Cement-Based Materials (ACBM).
References
Akita, H., Fujiwara, T., and Ozaka, Y. (1997). “A practical procedure for the analysis of moisture transfer within concrete due to drying.” Mag. Concrete Res., 49(179), 129–137.
Bentz, D. P., Ehlen, M. A., Ferraris, C. F., and Garboczi, E. J. (2001). “Sorptivity-based service life predictions for concrete pavements.” Proc., 7th Int. Conf. on Concrete Pavements, Orlando, Fla.
Dhir, R. K., Hewlett, P. C., and Chan, Y. N. (1987). “Near-surface characteristics of concrete: Assessment and development of insitu test methods.” Mag. Concrete Res., 39(141), 183–195.
Figg, J. W. (1973). “Methods for measuring the air and water permeability of concrete.” Mag. Concrete Res., 25(85), 213–219.
Geiker, M. (2004). “On the ingress of chlorides in cracked concrete.” ACBM Semi-Annual Meeting, Evanston, Ill.
Hall, C. (1989). “Water sorptivity of mortars and concretes: A review.” Mag. Concrete Res., 41(147), 51–61.
Hall, C., Hoff, W. D., and Skeldon, M. (1983). “The sorptivity of brick: Dependence on the initial water content.” J. Phys. D, 16(10), 1875–1880.
Hedenblad, G. (1993). Moisture permeability of mature concrete, cement mortar and cement paste, Division of Building Materials, Lund Institute of Technology, Lund, Sweden.
Hooton, R. D., Mesic, T., and Beal, D. C. (1993). “Sorptivity testing of concrete as an indicator of concrete durability and curing efficiency.” Proc., 3rd Canadian Symp. on Cement and Concrete, Ottawa, 264–275.
Kelham, S. (1988). “A water absorption test for concrete.” Mag. Concrete Res., 40(143), 106–110.
Kirkham, D., and Powers, W. L. (1972). Advanced soil physics, Wiley–Interscience, New York.
Levitt, M. (1970). “The ISAT—A non-destructive test for the durability of concrete.” Br. J. Non-Destr. Test., 13(4), 106–112.
McCarter, W. J. (1996a). “Monitoring the influence of water and ionic ingress on cover zone concrete subjected to repeated absorption.” J. Cem., Concr., Aggregates(ASTM), 18(1), 55–63.
McCarter, W. J., Emerson, M., and Ezirim, H. (1995). “Properties of concrete in the cover zone: Developments in monitoring techniques.” Mag. Concrete Res., 47(172), 243–251.
McCarter, W. J., Ezirim, H., and Emerson, M. (1992). “Absorption of water and chloride into concrete.” Mag. Concrete Res., 44(158), 31–37.
McCarter, W. J., Ezirim, H., and Emerson, M. (1996b). “Properties of concrete in the cover zone: Water penetration, sorptivity, and ionic ingress.” Mag. Concrete Res., 48(176), 149–156.
McCarter, W. J., and Garvin, S. (1989). “Dependence of electrical impedance of cement-based materials on their moisture condition.” J. Phys. D, 22(11), 1875–1880.
McCarter, W. J., and Watson, D. (1997). “Wetting and drying of cover-zone concrete.” Proc. Inst. Civ. Eng., Struct. Build., 112, 227–236.
Neville, A. M. (1996). Properties of concrete, 4th Ed., Wiley, New York.
Parrot, L. J. (1988). “Moisture profiles in drying concrete.” Adv. Cem. Res., 1(3), 164–170.
Rajabipour, F. (2003). “Fundamental investigations on utilizing electrical sensing to improve life-cycle modeling of concrete structures.” MSCE dissertation, Purdue Univ., West Lafayette, Ind.
Rajabipour, F., Weiss, J., and Abraham, D. (2004). “Insitu electrical conductivity measurements to assess moisture and ionic transport in concrete.” Advances in Concrete through Science and Engineering; Proc., Int. RILEM Symp., Evanston, Ill.
Schießl, A., Weiss, W. J., Shane, J. D., Berke, N. S., Mason, T. O., and Shah, S. P. (2000). “Assessing the moisture profile of drying concrete using impedance spectroscopy.” Concr. Sci. Eng., 2(2), 106–116.
Weiss, W. J. (1999). “Prediction of early-age shrinkage cracking in concrete.” PhD dissertation, Northwestern Univ., Evanston, Ill.
Weiss, W. J., Shane, J. D., Mieses, A., Mason, T. O., and Shah, S. P. (1999). “Aspects of monitoring moisture changes using electrical impedance spectroscopy.” Proc., 2nd Symp. on Self-Desiccation and Its Importance in Concrete Technology, Lund, Sweden.
Information & Authors
Information
Published In
Copyright
© 2005 ASCE.
History
Received: Aug 31, 2004
Accepted: Nov 22, 2004
Published online: Oct 1, 2005
Published in print: Oct 2005
Notes
Note. Associate Editor: Chiara F. Ferraris
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.