Fracture of Plain and Fiber-Reinforced Concrete Slabs under Monotonic Loading
Publication: Journal of Materials in Civil Engineering
Volume 16, Issue 5
Abstract
Monotonic load tests have been conducted on plain and fiber-reinforced concrete slabs on ground to monitor the effect of fiber type and dosage on the strength properties of concrete slabs. The results revealed that simple material tests do not always successfully predict the contribution of fibers in cases where structural geometry and boundary considerations control redistribution of load. The tensile cracking loads of plain and fibrous slabs were found to be similar, which had previously been reported for small- scale fiber specimens, but, there was a significant increase in the flexural strength of fiber-reinforced concrete slabs, relative to plain concrete slabs. Companion beam flexural strength tests also significantly underestimated the concrete slab flexural strength for both the plain and fibrous concrete slabs. The addition of fibers increased the collapse load of slabs, with the key factors affecting the magnitude of the collapse load being fiber type and quantity. Strain and deflection profile measurements showed that fibers assisted in crack propagation resistance, crack bridging, and load redistribution. The shape of the load deflection curves indicated that the synthetic and the steel-fiber-reinforced concrete slabs behaved similarly at different stages of cracking.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
AASHTO-AGC-ARTBA. ( 2001). “The use of state-of-the-practice of fiber reinforced concrete.” Task Force 36 Rep., Subcommittee on New Highway Materials, AASHTO-Associated General Contractors of America-American Road and Transportation Builders Association Joint Committee, Washington, D.C.
2.
American Concrete Institute (ACI). ( 1984). “Fiber reinforced concrete: International symposium.” SP-81, G. C. Hoff, ed., Detroit.
3.
American Concrete Institute (ACI). ( 1994). “Fiber reinforced concrete: Developments and innovations.” SP-142, J. I. Daniel and S. P. Shah, eds., Detroit.
4.
American Concrete Institute (ACI). ( 1997). “State-of-the-art report on fiber reinforced concrete.” ACI 544.1R-96, Farmington Hills, Mich.
5.
ASTM. ( 1986). “Standard test method for compressive strength of cylindrical concrete specimens.” C 39, vol. 4.02, West Conshohocken, Pa.
6.
ASTM. ( 1997). “Standard test method for flexural toughness and first crack strength of fiber reinforced concrete (using beam with third point loading).” C 1018, vol. 4.02, West Conshohocken, Pa.
7.
ASTM. ( 2002). “Standard specification for concrete aggregates.” C 33-02a, vol. 4.02, West Conshohocken, Pa.
8.
Barros, J. A. O., and Figueiras, J. A. (2001). “Model for the analysis of steel fibre reinforced concrete slabs on ground.” Comput. Struct., 79, 97–106.
9.
Baumann, R. A., and Weisgerber, F. E. (1983). “Yield-line analysis of slabs-on-grade.” J. Struct. Eng., 109(7), 1553–1568.
10.
Beckett, D. (1990). “Comparative tests on plain, fabric reinforced and steel fibre reinforced concrete ground slabs.” Concrete, 24(3), 43–45.
11.
Beckett, D. (1995). “Thickness design of concrete industrial ground floors.” Concrete, 29(4), 21–23.
12.
Beckett, D. (1998). “Thickness design methods for concrete industrial ground floors.” Concrete, 32(6), 12–16.
13.
Beckett, D. (2000). “Concrete ground slabs: An appraisal of corner loading.” Concrete, 34(8).
14.
Beckett, D., and Humphreys, J. ( 1989). “Comparative tests on plain, fabric reinforced and steel fibre reinforced concrete ground slabs.” Rep. No. TP/B/1, Thames Polytechnic School of Civil Engineering, Dartford, U.K.
15.
Beckett, D., Van De Woestyne, T., and Callens, S. (1999). “Corner and edge loading on ground floors reinforced with steel fibers.” Concrete 33(3), 22–24.
16.
Bentur, A., and Mindess, S. ( 1990). “Fibre reinforced cementitious composites.” Elsevier Applied Science, London.
17.
Concrete Society. ( 1994). “Concrete industrial ground floors — a guide to their design and construction.” Slough, Technical Rep. 34, 2nd Ed.
18.
Falkner, H., Huang, Z., and Teutsch, M. (1995). “Comparative study of plain and steel fibre reinforced concrete ground slabs.” Concr. Int., 17(1), 45–51.
19.
Falkner, H., and Teutsch, M. ( 1993). “Comparative investigations of plain and steel fibre reinforced industrial ground slabs.” No. 102, Institut Für Baustoffe, Massivbau und Brandschutz, Technical Univ. of Brunswick, Germany.
20.
Khazanovich, L. ( 1994). “Structural analysis of multi-layered concrete pavement systems.” PhD thesis, Univ. of Illinois, Urbana, Ill.
21.
Kukreja, C.B., et al. ( 1987). “Ultimate strength of fiber reinforced concrete slabs.” Proc. Int. Symp. on Fiber Reinforced Concrete, Madras, 1, 237–255.
22.
Meyerhof, G. G. (1962). “Load-carrying capacity of concrete pavements.” J. Soil Mech. Found. Div., 883, 89–116.
23.
Moens, J., and Nemegeer, D. (1991). “Designing fiber reinforced concrete based on toughness characteristics.” Concr. Int., 13(11), 38–43.
24.
Parker, F. ( 1974). “Steel fibrous concrete for airport pavement applications.” Technical Rep. 5-74-12, U.S. Army Engineer Waterways Experiment Station, Vicksburg, Miss.
25.
Portland Cement Association (PCA). ( 1991). Fiber reinforced concrete, Skokie, Ill.
26.
Rao, K. S. S., and Singh, S. (1986). “Concentrated load-carrying capacity of concrete slabs on ground.” J. Struct. Eng., 112(12), 2628–2645.
27.
Rieder, K. -A., et al. ( 2003). “Highly dispersible reinforcing polymeric fibers.” U.S. Patent No. 6,569,526.
28.
Roesler, J.R. ( 1998). “Fatigue of concrete beams and slabs.” PhD thesis, Univ. of Illinois, Urbana, Ill.
29.
Roesler, J.R., and Barenberg, E.J. ( 1999). “Effect of static and fatigue cracking on concrete strain measurements.” Transportation Research Record 1684, Washington, D.C. 51–60.
30.
Roesler, J.R., Lange, D., and Ulreich, G. ( 2003). “Fracture behavior of full-scale, fiber-reinforced concrete slabs.” Rep. prepared for W. R. Grace, Inc., Univ. of Illinois, Urbana, Ill.
31.
Rollings, R.S. ( 1981). “Corps of Engineers design procedures for rigid airfield pavements.” Proc., 2nd Int. Conf. on Concrete Pavement Design, Purdue Univ., West Lafayette, Ind.
32.
Romualdi, J. P., and Batson, G. B. (1963). “Mechanics of crack arrest in concrete.” J. Eng. Mech. Div., 89, 147–168.
33.
Romualdi, J. P., and Mandel, J. A. (1964). “Tensile strength of concrete affected by uniformly distributed closely spaced short lengths of wire reinforcement.” J. Am. Concr. Inst., 61, 657–671.
34.
Shah, S. P. (1991). “Do fibers increase the tensile strength of cement-based matrixes?” ACI Mater. J., 88(6), 595–602.
35.
Sham, S.H. R., and Burgoyne, C.J. ( 1986). “Load tests on dramix steel fibre reinforced concrete slabs.” A Rep. to Sir Frederick Snow and Partners, Consulting Engineers, Imperial College of Science and Technology, Dept. of Civil Engineering, Concrete Laboratories.
36.
Shentu, L., Jiang, D., and Hsu, C.-T. T. (1997). “Load-carrying capacity for concrete slabs on grade.” J. Struct. Eng., 123(1), 95–103.
37.
Tabatabaie, A. M., and Barenberg, E. J. (1980). “Structural analysis of concrete pavement systems.” Transp. Eng. J. ASCE, 106(5), 493–506.
38.
Tatnall, P. C., and Kuitenbrouwer, L. (1992). “Steel fiber reinforced concrete in industrial floors.” Concr. Int., 14(12), 43–47.
39.
Vondran, G. L. (1991). “Applications of steel fiber reinforced concrete.” Concr. Int., 13(11), 44–49.
40.
Westergaard, H. M. (1926). “Stresses in concrete pavements computed by theoretical analysis.” Public Roads, 7(2), 25–35.
Information & Authors
Information
Published In
Copyright
Copyright © 2004 ASCE.
History
Received: Jul 10, 2003
Accepted: Oct 28, 2003
Published online: Oct 1, 2004
Published in print: Oct 2004
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.