Ultrasonic Guided Waves for Inspection of Grouted Tendons and Bolts
Publication: Journal of Materials in Civil Engineering
Volume 15, Issue 3
Abstract
There is currently a need to improve the nondestructive testing techniques that are used to inspect grouted steel reinforcing tendons, anchors, and rock bolts for corrosion and fracture. A method of inspection using guided ultrasonic waves has been proposed, which uses a pulse-echo technique carried out from the free end of the structure. The maximum inspection range is determined by the amount of attenuation that the wave experiences as a result of leakage into the embedding material and material losses. However, previous work has identified high frequency modes that have low attenuation and so increase the inspection range. Research has been carried out with a focus on the inspection of the posttensioning tendons used to reinforce concrete. The research presented in this paper uses experimental techniques to measure the attenuation in short lengths of grouted tendons, to evaluate the reflection coefficient of the modes from different geometry breaks, and to assess the impact of tendon curvature. The outcome of this research shows that the inspection range for tendons is limited, but the outlook for the inspection of the larger diameter grouted bolts and rebars that are used in the construction industry is promising. Considerable success has already been achieved in the testing of epoxy bonded rock bolts using this method.
Get full access to this article
View all available purchase options and get full access to this article.
References
Beard, M. D., Lowe, M. J. S., and Cawley, P.(2001). “Inspection of rockbolts using guided ultrasonic waves.” Review of Progress in QNDE,20, 1156–1163.
Beard, M. D., Lowe, M. J. S., and Cawley, P.(2002). “Development of a guided wave inspection technique for rock bolts.” Insight, 44(1), 19–24.
Bernard, A., Lowe, M. J. S., and Deschamps, M.(2000). “Guided waves energy velocity in absorbing and non-absorbing plates.” J. Acoust. Soc. Am., 110, 186–196.
Lowe, M. J. S.(1995). “Matrix techniques for modelling ultrasonic waves in multilayered media.” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, Piscataway, N.J., 42, 525–542.
Lowe, M. J. S., and Diligent, O.(2001). “Reflection of the fundamental lamb modes from the ends of plates.” Review of Progress in QNDE, 20, 89–96.
Pavlakovic, B. N., and Lowe, M. J. S.(1999). “A general purpose approach to calculating the longitudinal and flexural modes of multi-layered, embedded, transversely isotropic cylinders.” Review of Progress in QNDE,18, 239–246.
Pavlakovic, B. N., Lowe, M. J. S., Alleyne, D. N., and Cawley, P.(1997). “Disperse: A general purpose program for creating dispersion curves.” Review of Progress in QNDE,16, 185–192.
Pavlakovic, B. N., Lowe, M. J. S., and Cawley, P.(1998). “Guided ultrasonic waves for the inspection of post-tensioned concrete bridges.” Review of Progress in QNDE,17, 1557–1564.
Pavlakovic, B. N., Lowe, M. J. S., and Cawley, P.(1999). “Prediction of reflection coefficients from defects in embedded bars.” Review of Progress in QNDE,18, 207–214.
Pavlakovic, B. N., Lowe, M. J. S., and Cawley, P.(2001). “High frequency low loss ultrasonic modes in imbedded bars.” J. Appl. Mech., 68, 67–75.
Silk, M. G., and Bainton, K. F.(1979). “The propagation in metal tubing of ultrasonic wave modes equivalent to Lamb waves.” Ultrasonics, 17, 11–19.
Vogt, T., Lowe, M. J. S., and Cawley, P.(2001). “Cure monitoring using guided ultrasonic waves in wires.” Review of Progress in QNDE,20, 1642–1649.
Woodward, R., and Williams, F.(1988). “Collapse of the Ynys-Gwas bridge, West Glamorgan.” Proc., Institution of Civil Engineers, London,84, 635–669.
Information & Authors
Information
Published In
Copyright
Copyright © 2003 American Society of Civil Engineers.
History
Received: Feb 20, 2002
Accepted: May 13, 2002
Published online: May 15, 2003
Published in print: Jun 2003
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.