Energy-Storing Wallboard: Flammability Tests
Publication: Journal of Materials in Civil Engineering
Volume 10, Issue 2
Abstract
Flammability tests were conducted on energy-storing wallboard—ordinary gypsum wallboard impregnated with approximately 24% organic phase change material (PCM). Such wallboard is able to store or release a significant amount of thermal energy. The major energy storage factor is the latent heat of the PCM, which is endothermic as PCM melts and exothermic as it crystallizes. A short presentation of the results obtained in the evaluation of such wallboard points out that flammability tests represent almost the last stage in this evaluation. The flammability tests evaluated the surface burning characteristics: flame spread and smoke development classifications determined in a Steiner tunnel, as well as heat and smoke release rates determined by cone calorimeter. The tests indicated that the energy-storing wallboard does not meet all requirements in the National Building Code regarding fire characteristics for building materials. Therefore, the possibility of reducing its flammability is discussed. Comparison of the test results with similar data for other building materials indicates the possibility of reducing the flammability of energy-storing wallboard by the incorporation of a flame retardant.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Feldman, D., Banu, D., and Hawes, D.(1995). “Low chain esters of fatty acids as phase change materials for thermal energy storage in buildings.”Solar Energy Mater. Solar Cells, 36, 311–322.
2.
Feldman, D., Banu, D., Hawes, D., and Ghanbari, E.(1991). “Obtaining an energy storing building material by direct incorporation of an organic phase change material in gypsum wallboard.”Solar Energy Mater., 22, 231–242.
3.
Grayson, S. J., Babrauskas, V., and Hirschler, M. (1994). “A new international standard for flammability testing.”Plastics Engrg., April, 29–31.
4.
Hawes, D., Feldman, D., and Banu, D.(1993). “Latent heat storage in building materials.”Energy and Buildings, 20, 77–86.
5.
Mehaffey, J. R. (1987). “Flammability of building materials and fire growth.”Proc., Building Sci. Insight '87, NRCC 28277. Inst. for Res. in Constr., Nat. Res. Council of Canada, Ottawa, 21–31.
6.
Petrella, R. V.(1994). “The assessment of full scale fire hazards from cone calorimeter data.”J. Fire Sci., 12, 14–43.
7.
Richardson, L. R., and Brooks, M. E. (1991). “Combustibility of building materials.”Proc., 16th Int. Conf. on Fire Safety, San Francisco, Calif., 287–299.
8.
Scalat, S., Banu, D., Hawes, D., Haghighat, F., Paris, J., and Feldman, D.(1996). “Full scale thermal testing of latent heat storage in wallboard.”Solar Energy Mater. Solar Cells, 44, 49–61.
9.
Telkes, M. (1975). “Thermal storage for solar heating and cooling.”Proc., Workshop on Solar Energy Storage Sys. for Heating and Cooling of Buildings, Charlottesville, Va., 17.
Information & Authors
Information
Published In
Copyright
Copyright © 1998 American Society of Civil Engineers.
History
Published online: May 1, 1998
Published in print: May 1998
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.