Two-Dimensional Micromachined Flow Sensor Array for Fluid Mechanics Studies
Publication: Journal of Aerospace Engineering
Volume 16, Issue 2
Abstract
We discuss two types of micromachined flow sensors realized by using novel microfabrication processes—a hot-wire anemometer (based on thermal transfer) and a biologically inspired flow sensor (based on momentum transfer). Both sensors are enabled by a new, efficient three-dimensional assembly technique called the plastic deformation magnetic assembly method. The sensors can be packaged in high-density, two-dimensional arrays efficiently, with each sensor node capable of performing two-component or three-component flow sensing. We first discuss the development of new hot-wire anemometers (HWA). The HWA uses a thermal element (hot wire) that is made of Pt/Ni/Pt film with a measured temperature coefficient of resistance of 2,700 ppm/°C. The thermal element is elevated out of plane by using support beams made of polyimide, a polymer material. Both steady-state and transient characteristics of the sensor have been experimentally obtained. The second type of flow sensor is based on momentum transfer principles and inspired by fish lateral line sensors. Each sensor consists of a vertical cilium attached to a horizontal cantilever. Fluid flow imparts moment on the vertical cilium, and causes the horizontal cantilever to bend. The fabrication process and preliminary measurement data are presented.
Get full access to this article
View all available purchase options and get full access to this article.
Reference
Ayers, J., Zavracky, P. M., McGruer, N., Massa, D., Vorus, V., Mukherjee, and R., Currie, S. (1998). “A modular behavioral-based architecture for biomimetic autonomous underwater robots.” Proc., Autonomous Vehicles in Mine Countermeasures Symposium, Naval Postgraduate School, (CD-Rom), world wide web site 〈http://www.cis.plym.ac.uk/cis/InsectRobotics/biomimetics.htm〉 (1998).
Blackwelder, R. F. (1981). Methods of experimental physics: Fluid dynamics, Vol. 18, Part A, Academic, New York, 99–154.
Boillat, M. A., van der Wiel, A. G., Hoogerwerf, A. C., and de Rooij, N. F. (1995). “A differential pressure liquid flow sensor for flow regulation and dosing systems.” Proc., IEEE Micro Electro Mechanical Systems, 350–2.
Bond, C. E. (1996). Biology of fishes, 2nd Ed., Saunders, Philadelphia.
Brunn, H. H. (1995). Hot-wire anemometry: Principles and signal analysis, Oxford University Press, New York.
de Bree, H. E., Jansen, H. V., Lammerink, T. S. J., Krijnen, G. J. M., and Elwenspoek, M.(1999). “Bi directional fast flow sensor with a large dynamic range.” J. Micromech. Microeng., 9(2), 186–9.
Dittmann, D., Ahrens, R., Rummler, Z., Schlote-Holubek, K., and Schomberg, W. K. (2001). “Low-cost flow transducer fabricated with the AMANDA-process.” 11th Int. Conf. on Solid-State Sensors and Actuators, Munich, Germany, June 10–14, 1472–1475.
Ebefors, T., Kalvesten, E., and Stemme, G. (1998). “Three dimensional silicon triple-hot-wire anemometer based on polyimide joints.” Proc. Eleventh Annual Int. Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems, 93–8.
Enoksson, P., Stemme, G., and Stemme, E. (1996). “A Coriolis mass flow sensor structure in silicon.” Proc., 9th Annual Int. Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems, 156–61.
Freymuth, F. (1977). “Frequency response and electronic testing for constant temperature hot-wire anemometers.” J. Phys. E, 10.
Goldstein, R. J. (1983). Fluid mechanics measurements, Hemisphere, Washington.
HD Microsystems. (1998). “Pyralene polyimide coating for electronics: PI2610 series—Product information and process guidelines.” HD Microsystems.
Jiang, F., Tai, T. C., Ho, C. M., Rainer, K., and Garstenauer, M. (1994). “Theoretical and experimental studies of micromachined hot-wire anemometer.” Digest IEEE Int. Electron Devices Meetings (IEDM), 139–142.
Kalvesten, E., Vieider, C., Lofdahl, L., and Stemme, G.(1996). “An integrated pressure-flow sensor for correlation measurements in turbulent gas flows.” Sens. Actuators A, A52(1–3), 51–8.
Kovacs, G. T. A. (1998). Micromachined transducers sourcebook, McGraw-Hill, New York.
Lofdahl, L., Kalvesten, E., Hadzianagnostakis, T., and Stemme, G. (1996). “An integrated silicon based wall pressure-shear stress sensor for measurements in turbulent flows.” Proc., 1996 Int. Mechanical Engineering Congress and Exposition, 245–51.
Lofdahl, L., Stemme, G., and Johansson, B.(1992). “Silicon based flow sensors used for mean velocity and turbulence measurements.” Exp. Fluids, 12(4–5), 270–6.
Lomas, C. G. (1986). Fundamentals of hot wire anemometry, Cambridge University Press, Cambridge, England.
Middelhoek, S., and Audet, S. A. (1989). Microelectronics and signal processing: Silicon sensors, Academic, New York.
Neda, T., Nakamura, K., and Takumi, T.(1996). “A polysilicon flow sensor for gas flow meters.” Sens. Actuators A, 54, 621–31.
Ozaki, Y., Ohyama, T., Yasuda, T., and Shimoyama, I. (2000). “An air flow sensor modeled on wind receptor hairs of insects.” Proc., MEMS 2000, 531–6.
Padmanabhan, Goldberg, H., Breuer, K. D., and Schmidt, M. A.(1996). “A wafer-bonded floating-element shear stress microsensor with optical position sensing by photodiodes.” J. Microelectromech. Syst., 5(4), 307–15.
Perry, A. E. (1982). Hot wire anemometry, Clarendon, Oxford, England.
Pfann, W. G., and Thurston, R. N.(1961). “Semiconducting stress transducers utilizing the transverse and shear piezoresistance effects.” J. Appl. Phys., 32(10), 2008–19.
Rediniotis, O. K., and Vijayagopal, R.(1999). “Miniature multihole pressure probes and their neural-network-based calibration.” AIAA J., 37(6), pp. 666–74.
Richter, M., Wackerle, M. Woias, P., and Hillerich, B. (1999). “A novelflow sensor with high time resolution based on differential pressure principle.” Proc., 12th Int. Conf. on Micro Electro Mechanical Systems, Orlando, Fla. 118–123.
Svedin, N., Kalvesten, E., Stemme, E., and Stemme, G.(1998). “A new silicon gas-flow sensor based on lift force.” J. Microelectromech. Syst., 7(3), 303–308.
Svedin, N., Stemme, E., and Stemme, G. (2001). “A static turbine flow meter with a micromachined silicon torque sensor.” Technical Digest, MEMS 2001, 14th IEEE Int. Conf. on Micro Electro Mechanical Systems, Interlaken, Switzerland, 208–211.
van Baar, J. J., Wiegerink, R. J., Lammerink, T. S. J., Krijnen, G. J. M., and Elwenspoek, M.(2001). “Micromachined structures for thermal measurements of fluid and flow parameters.” J. Micromech. Microeng., 11(4), 311–8.
van der Wiel, A. J., Boillat, M. A., and de Rooij, N. F. (1995). “A bi-directional silicon orifice flow sensor characterised for fluid temperature and pressure.” Proc., 8th Int. Conf. on Solid-State Sensors and Actuators and Eurosensors IX, Vol. 2, 420–3.
van der Wiel, A. J., Linder, C., de Rooij, N. F., and Bezinge, A.(1993). “A liquid velocity sensor based on the hot-wire principle.” Sens. Actuators A, A37–38, 693.
van Honschoten, J. W., Krijnen, G. J. M., Svetovoy, V. B., de Bree, H. E., and Elwenspoek, M. C. (2001). “Optimization of a two wire thermal sensor for flow and sound measurements.” Proc., 14th Int. Conf. Micro Electro Mechanical Systems (MEMS’2001), 523–526
Weidman, P. D., and Browand, F. K.(1975). “Analysis of a simple circuit for constant temperature anemometry.” J. Phys. E, 8(2), 553–560.
White, F. M. (1999). Fluid mechanics, 4th Ed., McGraw-Hill, New York.
Xu, Y., Jiang, F., Lin, Q., Clendenen, J., Tung, S., and Tai, Y. C. (2002). “Under water shear stress sensor.” Proc., 15th IEEE Int. Conf. on Micro Electro Mechanical Systems (MEMS’02).
Zou, J., Chen, J., and Liu, C.(2001). “Plastic deformation magnetic assembly (PDMA) of out-of-plane microstructures: Technology and application.” IEEE/ASME J. MEMS,10(2), 302–309.
Information & Authors
Information
Published In
Copyright
Copyright © 2003 American Society of Civil Engineers.
History
Received: Nov 6, 2002
Accepted: Nov 6, 2002
Published online: Mar 14, 2003
Published in print: Apr 2003
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.