Assessment of Fire Damage to a Reinforced Concrete Structure during Construction
Publication: Journal of Performance of Constructed Facilities
Volume 21, Issue 4
Abstract
This article summarizes an engineering evaluation of the extent of fire damage to a concrete structure under construction. The fire occurred in a portion of the reinforced concrete structure and visibly damaged a load bearing exterior foundation wall. The purpose of the assessment was to promptly evaluate the in situ condition of the wall and recommend necessary repair or replacement options prior to commencement of backfilling and the concrete construction to be supported by the subject wall. The engineering assessment of the damaged wall included a nondestructive evaluation phase consisting of ultrasonic pulse velocity testing and a laboratory testing phase on the concrete cores removed from the damaged wall. Dynamic Young’s modulus of elasticity and an air permeability index of thick disks sawed from the cores were determined. Analysis of properties of concrete specimens permitted assessment of the presence and degree of any damage in smaller depth increments compared to the size of a compressive strength core. Significant differences were not indicated by compressive strength of cores, however, the in situ nondestructive testing and laboratory testing of the disks were effective in determining the depth of damage, as a result of the fire. The results of the nondestructive and laboratory evaluation indicated that the distressed zone of the concrete was limited to a near-surface layer. Repair recommendations were based on removal and replacement of the affected concrete sections identified by the testing program.
Get full access to this article
View all available purchase options and get full access to this article.
References
American Concrete Institute. (2003). “Nondestructive test methods for evaluation of concrete in structures ACI 228.2R.” Committee Rep. 228 American Concrete Institute Manual of Concrete Practice, Vol. 2, Farmington Hills, Mich.
ASTM. (2003a). “Standard test method for pulse velocity through concrete.” Annual book of American Society of Testing and Materials, C 597-02, West Conshohocken, Pa., 04–02.
ASTM. (2003b). “Standard test method for fundamental transverse, longitudinal, and torsional frequencies of concrete specimens.” Annual book of American Society of Testing and Materials, C 215-02, West Conshohocken, Pa., 04–02.
ASTM. (2003c). “Standard test method for penetration resistance of hardened concrete.” Annual book of American Society of Testing and Materials, C 803/C 803M-03, West Conshohocken, Pa., 04–02.
ASTM. (2003d). “Standard test method for obtaining and testing drilled cores and sawed beams of concrete.” C 42-03, Annual book of American Society of Testing and Materials, West Conshohocken, Pa., 04–02.
Chung, H. W., and Law, K. S. (1985). “Assessing fire damage of concrete by the ultrasonic pulse technique.” Cement, concrete, and aggregates, ASTM, 7(2), West Conshohocken, Pa., 84–88.
Dilek, U. (2000). Effects of manufactured sand characteristics on properties of concrete, Doctoral dissertation, North Carolina State Univ., Raleigh, N.C.
Dilek, U., Caldwell, T., Sharpe, E. F., and Leming, M. L. (2003). “Fire damage assessment, prestressed concrete double-tees in a parking deck.” Forensic Engineering: Proc., 3rd Congress, P. A. Bosela et al., eds., ASCE, Reston, Va., 247–258.
Dilek, U., Leming, M. L., and Guth, D. (2004). “The relationship between elastic modulus and permeability of damaged concrete.” Transportation Research Record: J. Transportation Research Board, Transportation Research Board, Washington, D.C., 1893(2004), 5360.
Leming, M. L., Nau, J. M., and Fukuda, J. (1998). “Nondestructive determination of the dynamic modulus of concrete disks.” ACI Mater. J., 95(1), 50–57.
Naik, T. R., and Malhotra, V. M. (1991). “The ultrasonic pulse velocity method.” Handbook on nondestructive testing of concrete, Chapter 7, V. M. Malhotra and N. J. Carino, eds., CRC, Boca Raton, Fla., 169–188.
Schonlin, K., and Hilsdorf, H. K. (1988). “Permeability as a measure of potential durability of concrete—Development of a suitable test apparatus.” Permeability of concrete, SP-108, American Concrete Institute, Detroit, 99–115.
Tovey, A. K. (1986). “Assessment and repair of fire damaged concrete structures—An update.” Evaluation and repair of fire damage to concrete, SP-92, American Concrete Institute, Detroit, p. 50.
Information & Authors
Information
Published In
Copyright
© 2007 ASCE.
History
Received: May 24, 2004
Accepted: Aug 31, 2004
Published online: Aug 1, 2007
Published in print: Aug 2007
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.