Splitting Failures in Trapezoidal Steel Roof Cladding
Publication: Journal of Performance of Constructed Facilities
Volume 18, Issue 1
Abstract
High wind events such as hurricanes and storms often cause severe damage to crest-fixed thin steel roof claddings. Past research on wind damage has shown that low cycle fatigue cracking of steel roof sheeting around the fastener holes has been the reason for the premature pull-through failures of roof claddings under fluctuating wind forces. Such a situation will be at its worst if the roof sheeting is already split at the fastener holes. An inspection of trapezoidal steel roofs has shown that roofing has been split in the transverse direction due to overtightening of screw fasteners accidental or caused by poor workmanship. Once split, even slightly, the roofing can survive only a few cycles of wind uplift loading. Therefore an investigation using laboratory experiments and finite element analyses was carried out to study the splitting behavior of two commonly used high tensile steel trapezoidal roof claddings. The analytical and experimental results agree reasonably well and present a good understanding of the splitting behavior of trapezoidal roof claddings. This paper presents the details of this investigation and the results.
Get full access to this article
View all available purchase options and get full access to this article.
References
Beck, V. R., and Stevens, L. K.(1979). “Wind loading failures of corrugated roof cladding.” Civ. Eng. Trans., I. E. Aust., 21(1), 45–56.
Broken Hill Proprietary (BHP) Building Products. (1990). Design and installation manual, Sydney, Australia.
Hibbitt, Karlsson, and Sorensen (HKS). (1997). ABAQUS user manual, Hibbitt, Karlsson, and Sorensen, Pawtucket, R.I.
ITW Construction Products. (1995). Buildex screw book, Melbourne, Australia.
Mahaarachchi, D., and Mahendran, M. (2000). “Pull-through failures of crest-fixed steel claddings initiated by transverse splitting.” Proc., 15th Int. Specialty Conf. on Cold-Formed Steel Structures, Univ. of Missouri at Rolla, Rolla, Mo., 635–646.
Mahendran, M.(1990). “Fatigue behaviour of corrugated roofing under cyclic wind loading.” Civ. Eng. Trans., I. E. Aust., 32(4), 211–218.
Mahendran, M.(1994a). “Steel roof claddings under simulated cyclonic wind forces.” Civ. Eng. Trans., I. E. Aust., 36(1), 1–10.
Mahendran, M.(1994b). “Behaviour and design of crest-fixed profiled steel roof claddings under high wind forces.” Eng. Struct., 16(5), 368–376.
Mahendran, M.(1995). “Wind-resistant low-rise buildings in the tropics.” J. Perform. Constr. Facil., 9(4), 330–346.
Reardon, G. F., and Mahendran, M. (1988). “Simulated wind loading of a Melbourne brick veneer house.” Technical Rep. No. 34, Cyclone Testing Station, James Cook Univ. of North Queensland, Townsville, Australia.
Tang, R. B., and Mahendran, M. (1999). “Pull-over strength of trapezoidal steel claddings.” Proc., 4th Int. Conf. on Steel and Aluminium Structures, Univ. of Technology, Helsinki, Finland, 609–616.
Information & Authors
Information
Published In
Copyright
Copyright © 2004 American Society of Civil Engineers.
History
Received: Jan 9, 2002
Accepted: Oct 11, 2002
Published online: Jan 16, 2004
Published in print: Feb 2004
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.