The current paper aims at the assessment of the effectiveness of a popular transient-based technique—inverse transient analysis (ITA)—for leak detection in water pipe systems using physical data. Data were collected from two pipe systems made of polyethylene: a laboratory facility at Imperial College London and a quasi-field system at Thames Water Utilities. A hydraulic transient solver especially developed for viscoelastic pipes (typically made of polyethylene) and an optimization algorithm for the simultaneous creep calibration and leak location have been developed for the application of this technique. The evaluation of the presence, location, and size of leaks was carried out using collected data. ITA allowed for the identification of the approximate location of leaks as long as the physical characteristics of the pipeline are well known, the transient is generated by a fast change of flow conditions, the leak has a “reasonable size,” and the transient solver is accurate enough to describe the transient event.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers acknowledge the financial support of this research work to the U.K. Engineering and Physical Sciences Research Council under the EPSRC WITE Grant No. UNSPECIFIEDGR/M68213.
References
Brunone, B. (1999). “Transient test-based technique for leak detection in outfall pipes.” J. Water Resour. Plann. Manage., 125(5), 302–306.
Brunone, B., and Ferrante, M. (2001). “Detecting leaks in pressurised pipes by means of transients.” J. Hydraul. Res., 39(5), 539–547.
Covas, D., and Ramos, H. (1999). “Leakage detection single pipelines using pressure wave behaviour.” Water industry systems: Modeling and optimization applications, D. Savic and G. Walters, eds., Research Studies Press, Hertfordshire, England, 287–299.
Covas, D., Ramos, H., Graham, N., and Maksimovic, C. (2005a). “Application of hydraulic transients for leak detection in water supply systems.” Water Sci. Technol.: Water Supply, 4(5–6), 365–374.
Covas, D., Ramos, H., Young, A., Graham, N., and Maksimovic, C. (2005b). “Uncertainties of leak detection by means of hydraulic transients: From the lab to the field.” Proc., 8th Int. Conf. on Computing and Control for the Water Industry (CCWI 2005), Univ. of Exeter, Exeter, UK, 143–148.
Covas, D., Stoianov, I., Mano, J., Ramos, H., Graham, N., and Maksimovic, C. (2004). “The dynamic effect of pipe-wall viscoelasticity in hydraulic transients. Part I—Experimental analysis and creep characterization.” J. Hydraul. Res., 42(5), 516–530.
Covas, D., Stoianov, I., Mano, J., Ramos, H., Graham, N., and Maksimovic, C. (2005c). “The dynamic effect of pipe-wall viscoelasticity in hydraulic transients. Part II—Model development, calibration and verification.” J. Hydraul. Res., 43(1), 56–70.
Ferrante, M., and Brunone, B. (2003). “Pipe system diagnosis and leak detection by unsteady tests. 2: Wavelet analysis.” Adv. Water Resour., 26, 107–116.
Hunaidi, O., Chu, W., Wang, A., and Guan, W. (1998). “Effectiveness of leak detection methods for plastic water distribution pipes.” Proc., Workshop on Advancing the State of our Distribution Systems—The Practical Benefits of Research. AWWA Dist. System Symp., AWWA, Denver.
Hunaidi, O., Chu, W., Wang, A., and Guan, W. (1999). “Leakage detection methods for plastic water distribution pipes.” Proc., Advancing the Science of Water—AWWA Research Foundation Technology Transfer Conf., AWWA, Denver, 249–263.
Kapelan, Z., Savic, D., and Walters, G. (2003). “A hybrid inverse transient model for leakage detection and roughness calibration in pipe networks.” J. Hydraul. Res., 41(5), 481–492.
Liggett, J. A., and Chen, L. C. (1994). “Inverse transient analysis in pipe networks.” J. Hydraul. Eng., 120(8), 934–955.
Nash, G. A., and Karney, B. (1999). “Efficient inverse transient analysis in series pipe systems.” J. Hydraul. Eng., 125(7), 761–764.
Trikha, A. K. (1975). “An efficient method for simulating frequency-dependent friction in transient liquid flow.” J. Fluids Eng., 97(1), 97–105.
Vardy, A. E., Hwang, K. L., and Brown, J. (1993). “A weighting function model of transient turbulent pipe friction.” J. Hydraul. Res., 31(4), 533–548.
Vitkovsky, J. P., Lambert, M. F., and Simpson, A. R. (2000a). “Advances in unsteady friction modelling in transient pipe flow.” Proc., 8th Int. Conf. on Pressure Surges-Safe Design and Operation of Industrial Pipe Systems, A. Anderson, ed., BHR Group, Suffolk, U.K., 471–498.
Vitkovsky, J. P., Lambert, M. F., Simpson, A. R., and Liggett, J. A. (2007). “Experimental observation and analysis of inverse transients for pipeline leak detection.” J. Water Resour. Plann. Manage., 133(6), 519–530.
Vitkovsky, J. P., Simpson, A. R., and Lambert, M. F. (2000b). “Leak detection and calibration issues using transient and genetic algorithms.” J. Water Resour. Plann. Manage., 126(4), 262–265.
Wang, X. J., Lambert, M. F., Simpson, A. R., Liggett, J. A., and Vitkovsky, J. P. (2002). “Leak detection in pipelines using damping of fluid transients.” J. Hydraul. Eng., 128(7), 697–711.
Information & Authors
Information
Published In
Copyright
© 2010 ASCE.
History
Received: Sep 15, 2006
Accepted: Oct 5, 2009
Published online: Feb 12, 2010
Published in print: Mar 2010
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.