Comparative Evaluation of Base-Isolated and Fixed-Base Buildings Using a Comprehensive Response Index
Publication: Journal of Structural Engineering
Volume 135, Issue 6
Abstract
Although current code guidelines specify different seismic performance objectives for fixed-base and isolated buildings, the future of performance-based design will allow user-selected performance objectives, motivating the need for a consistent performance comparison of the two systems. Based on response history analysis to a suite of motions, constant ductility spectra are generated for fixed-base and isolated buildings. Both superstructure force (base shear) and deformation demands in base-isolated buildings are lower than in fixed-base buildings responding with identical deformation ductility. To compare the relative performance of many systems or to predict the best system to achieve a given performance objective, a response index is developed and used for rapid prototyping of response as a function of system characteristics. When evaluated for a life safety performance objective, the superstructure design base shear of an isolated building is competitive with that of a fixed-base building with identical ductility, and the isolated building generally has improved response. Isolated buildings can meet a moderate ductility immediate-occupancy objective at low design strengths, whereas comparable ductility fixed-base buildings fail to meet the objective.
Get full access to this article
View all available purchase options and get full access to this article.
References
Applied Technology Council (ATC). (2007). “Guidelines for seismic performance assessment of buildings 35% complete.” Draft prepared for the Department of Homeland Security, Washington, D.C.
Ceccoli, C., Mazzotti, C., and Savoia, M. (1999). “Nonlinear seismic analysis of base-isolated RC frame structures.” Earthquake Eng. Struct. Dyn., 28(6), 633–653.
Chopra, A. K. (2007). Dynamics of structures: Theory and applications to earthquake engineering, 3rd Ed., Prentice-Hall, Upper Saddle River, N.J.
International Conference of Building Officials (ICBO). (1991). Uniform building code, Whittier, Calif.
International Conference of Building Official (ICBO). (1997). Uniform building code, Vol. 2, Whittier, Calif.
Kikuchi, M., Black, C. J., and Aiken, I. D. (2008). “On the response of yielding seismically isolated structures.” Earthquake Eng. Struct. Dyn., 37(5), 659–679.
Krawinkler, H., ed. (2005). “Van Nuys hotel building testbed report: Exercising seismic performance assessment.” PEER 2005-11, Pacific Earthquake Engineering Research Center, Univ. of California, Berkeley, Calif.
Lin, A. N., and Shenton, H. W., III. (1992). “Seismic performance of fixed-base and base-isolated steel frames.” J. Eng. Mech., 118(5), 921–941.
Mayes, R. L., Jones, L. R., and Kelly, T. E. (1990). “The economics of seismic isolation in buildings.” Earthquake Spectra, 6(2), 245–263.
Miranda, E., and Aslani, H. (2003). “Probabilistic response assessment for building specific loss estimation.” PEER 2003-03, Pacific Earthquake Engineering Research Center, Univ. of California, Berkeley, Calif.
Miranda, E., and Taghavi, S. (2005). “Approximate floor acceleration demands in multi-story buildings. II: Application.” J. Struct. Eng., 131(2), 212–220.
Naaseh, S., Morgan, T. A., and Walters, M. T. (2002). “A critical evaluation of current U.S. building code provisions and FEMA guidelines for the design of seismic isolated structures.” Proc., ATC 17-2 Seminar on Seismic Isolation, Passive Energy Dissipation and Active Control, Applied Technology Council, Los Angeles.
Ordonez, D., Foti, D., and Bozzo, L. (2003). “Comparative study of the inelastic response of base isolated buildings.” Earthquake Eng. Struct. Dyn., 32(1), 151–164.
Palazzo, B., and Petti, L. (1996). “Reduction factors for base isolated structures.” Comput. Struct., 60(6), 945–956.
Porter, K., Kennedy, R., and Bachman, R. (2007). “Creating fragility functions for performance-based earthquake engineering.” Earthquake Spectra, 23(2), 471–489.
Ryan, K. L., and Chopra, A. K. (2004). “Estimation of seismic demands on isolators based on nonlinear analysis.” J. Struct. Eng., 130(3), 392–402.
Ryan, K. L., Morgan, T. A., and Sayani, P. (2006). “Consistent performance comparison of seismic-isolated and fixed-base buildings.” Proc., 8th U.S. National Conf. of Earthquake Engineering, San Francisco, Earthquake Engineering Research Institute, Oakland, Calif., Paper No. 1617.
Sayani, P. J., and Ryan, K. L. (2009). “Evaluation of approaches to characterize seismic isolation systems for design.” J. Earthquake Eng., in press.
Shenton, H. W., III, and Lin, A. N. (1994). “Relative performance of fixed-base and base-isolated concrete frames.” J. Struct. Eng., 119(10), 2952–2968.
Somerville, P., Anderson, D., Sun, J., Punyamurthula, S., and Smith, N. (1998). “Generation of ground motion time histories for performance-based seismic engineering.” Proc., 6th U.S. National Conf. of Earthquake Engineering, Seattle, Earthquake Engineering Research Institute, Oakland, Calif.
Structural Engineers Association of California (SEAOC). (1995). Vision 2000—Performance based seismic engineering of buildings, Vols. I, II, Vision 2000 Committee, Sacramento, Calif.
Information & Authors
Information
Published In
Copyright
© 2009 ASCE.
History
Received: Jul 13, 2007
Accepted: Dec 9, 2008
Published online: May 15, 2009
Published in print: Jun 2009
Notes
Note. Associate Editor: Panos Tsopelas
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.