Special Perforated Steel Plate Shear Walls with Reduced Beam Section Anchor Beams. I: Experimental Investigation
This article is a reply.
VIEW THE ORIGINAL ARTICLEThis article has a reply.
VIEW THE REPLYPublication: Journal of Structural Engineering
Volume 135, Issue 3
Abstract
This paper presents results of an experimental investigation of specially detailed ductile perforated steel plate shear walls (SPSWs) designed to accommodate utility passage, and having anchor beams with reduced beam sections connections. Single-story, single-bay SPSW frames are subjected to quasi-static cyclic loading up to their maximum strength and displacement capacity. The tested specimens also had low yield strength steel infill panels. Two specimens make allowances for penetration of the panel by utilities. The first, having multiple holes specially laid out in the steel panel, also has the characteristic of reduced panel strength and stiffness compared to the corresponding SPSW having a solid panel. The second such specimen utilizes quarter-circle cutouts in the panel corners, which are reinforced to transfer the panel forces to the adjacent framing. A SPSW with solid panel is also tested for reference purposes. All specimens resisted an imposed input history of increasing displacements to a minimum drift of 3%. The perforated panel reduced the elastic stiffness and overall strength of the specimen by 15% as compared with the solid panel specimen.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This work was supported in part by the Earthquake Engineering Research Centers Program of the National Science Foundation under Award No. NSFECC-9701471 to the Multidisciplinary Center for Earthquake Engineering Research. The assistance of Dr. Gordon Warn during manuscript preparation is also appreciated. However, any opinions, findings, conclusions, and recommendations presented in this paper are those of the writers and do not necessarily reflect the views of the sponsors.
References
AISC. (2005a). “Prequalified connections for special and intermediate steel moment frames for seismic applications.” ANSI/AISC 358-05, American Institute of Steel Construction, Inc., Chicago, Ill.
AISC. (2005b). “Seismic provisions for structural steel buildings.” ANSI/AISC 341-05, American Institute of Steel Construction, Inc., Chicago, Ill.
Applied Technology Council (ATC). (1992). “Guidelines for seismic testing of components of steel structures.” Rep. No. 24, ATC, Redwood City, Calif.
Berman, J. W., and Bruneau, M. (2003a). “Experimental investigation of light-gauge steel plate shear walls for the seismic retrofit of buildings.” Technical Rep. No. MCEER-03-0001, Multidisciplinary Center for Earthquake Engineering Research, Buffalo, N.Y.
Berman, J. W., and Bruneau, M. (2003b). “Plastic analysis and design of steel plate shear walls.” J. Struct. Eng., 129(11), 1148–1156.
Berman, J. W., and Bruneau, M. (2005). “Experimental investigation of light-gauge steel plate shear walls.” J. Struct. Eng., 131(2), 259–267.
CAN/CSA. (2001). “Limit states design of steel structures.” S16-01, Canadian Standards Association, Mississauga, Ontario, Canada.
Computers and Structures Inc. (CSI). (2002). SAP2000: Analysis reference manual, Ver. 8.0, Berkeley, Calif.
Driver, R. G., Kulak, G. L., Kennedy, D. J. L., and Elwi, A. E. (1997). “Seismic behavior of steel plate shear walls.” Structural Engineering Rep. No. 215, Dep. of Civil and Environmental Engineering, Univ. of Alberta.
FEMA. (2000). “Recommended seismic design criteria for new steel moment-frame buildings.” FEMA 350, SAC Joint Venture for the Federal Emergency Management Agency, Washington, D.C.
FEMA. (2003). “FEMA 450: “NEHRP recommended provisions for seismic regulations For new buildings and other structures.” FEMA 450, Building Seismic Safety Council for the Federal Emergency Management Agency, Washington, D.C.
Leontovich, V. (1959). Frames and arches: Condensed solutions for structural analysis, McGraw-Hill, New York.
Roberts, T., and Sabouri-Ghomi, S. (1992). “Hysteretic characteristics of unstiffened perforated steel plate shear panels.” Thin-Walled Struct., 14, 139–151.
Sabelli, R., and Bruneau, M. (2006). “Steel plate shear walls.” Steel design guide, American Institute of Steel Construction, Inc., Chicago, Ill.
Thorburn, L. J., Kulak, G. L., and Montgomery, C. J. (1983). “Analysis of steel plate shear walls.” Structural Engineering Rep. No. 1073, Dept. of Civil Engineering, Univ. of Alberta, Edmonton, Alberta, Canada.
Timler, P. A., and Kulak, G. L. (1983). “Experimental study of steel plate shear walls.” Structural Engineering Rep. No. 114, Dept. of Civil Engineering, Univ. of Alberta, Edmonton, Alberta, Canada.
Vian, D., and Bruneau, M. (2005). “Steel plate shear walls for seismic design and retrofit of building structures.” Tech. Rep. No. MCEER-05-0010, Multidisciplinary Center for Earthquake Engineering Research, State Univ. of New York at Buffalo, Buffalo, N.Y.
Xue, M., and Lu, L.-W. (1994). “Interaction of infilled steel shear wall panels with surrounding frame members.” Proc., 1994 Annual Task Group Technical Session, Structural Stability Research Council: Reports on Current Research Activities, 339–354.
Yang, T. Y., and Whittaker, A. S. (2002). “MCEER demonstration hospitals—Mathematical models and preliminary results.” Technical Rep., Multidisciplinary Center for Earthquake Engineering Research, Univ. at Buffalo, Buffalo, N.Y.
Information & Authors
Information
Published In
Copyright
© 2009 ASCE.
History
Received: Jun 22, 2007
Accepted: Nov 5, 2008
Published online: Mar 1, 2009
Published in print: Mar 2009
Notes
Note. Associate Editor: Benjamin W. Schafer
Authors
Metrics & Citations
Metrics
Citations
Download citation