Component and Cladding Wind Loads for Soffits
Publication: Journal of Structural Engineering
Volume 134, Issue 5
Abstract
The wind induced failure of soffits of low rise structures is a failure mechanism commonly observed in post hurricane damage investigations. The failure of the soffits has the potential to allow both wind and water to enter the attic space of the building. The current US national wind loading standard (ASCE 7) provides no guidance as to the wind load requirements for the design of soffits. In order to address this deficiency, wind tunnel tests on 1:50 scale models of one-, two-, and three-story hip and gable roof buildings were performed where measurements of the wind induced pressures and suctions on the soffits, roofs, and walls were obtained. The wind tunnel tests were performed in open and suburban terrain conditions, with and without surrounding buildings in place. The results of the tests clearly show that the soffit pressures are nearly fully correlated with nearby wall pressures, and a simple and accurate solution to the soffit loading deficiency in ASCE 7 is to prescribe that the component and cladding pressures for use in the design of soffits be identical to the component and cladding loads used for the design of wall components.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
This study was funded by the Florida Department of Community Affairs and the State Farm Mutual Insurance Company. The views and opinions expressed in this paper are those of the writer.
References
ASCE. (2006). “Minimum design loads for buildings and other structures.” ASCE 7-05, Reston, Va.
ESDU. (1982). “Strong winds in the atmospheric boundary layer. Part I: Mean hourly wind speed.” Engineering sciences data unit item No. 82026, London.
FEMA. (2005a). “Mitigation assessment team report: Hurricane Charley in Florida, observations, recommendations, and technical guidance.” FEMA Rep. No. 488, FEMA, Washington, D.C.
FEMA. (2005b). “Mitigation assessment team report: Hurricane Ivan in Alabama and Florida, observations, recommendations, and technical guidance.” FEMA Rep. No. 489, FEMA, Washington, D.C.
Kopp, G. A., Surry, D., and Mans, C. (2005). “Wind effects of parapets on low buildings: Part I. Basic aerodynamics,” J. Wind. Eng. Ind. Aerodyn., (93), 817–841.
Information & Authors
Information
Published In
Copyright
© 2008 ASCE.
History
Received: Aug 30, 2006
Accepted: Jul 23, 2007
Published online: May 1, 2008
Published in print: May 2008
Notes
Note. Associate Editor: Kurtis R. Gurley
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.