Experimental and Numerical Investigation of the Tensile Behavior of Blind-Bolted T-Stub Connections to Concrete-Filled Circular Columns
Publication: Journal of Structural Engineering
Volume 134, Issue 2
Abstract
This paper presents the results of two series of experimental and analytical studies on the structural behavior of an innovative moment-resisting connection to concrete-filled circular hollow sections using blind bolts. The first part of the paper presents a large-scale T-stub connection with full instrumentation tested to failure in tension, and the second part presents a series of pullout tests to explore the anchorage behavior of cogged bars within concrete-filled steel tubes. The favorable strength and stiffness characteristics of this type of connection showed that it could be an alternative to conventional welded moment-resisting connections. A 3D finite-element (FE) model was developed to simulate the behavior of blind-bolted T-stub connections when subject to tension. The FE model took into account material nonlinearities, geometrical discontinuities, and complex contact interactions among the bolt heads, tube wall, end plates, and nuts. The FE results were found to be in good quantitative agreement with the actual connection behavior. A stiffness model composed of various nonlinear springs was also developed to predict the pullout behavior of cogged bars within concrete-filled steel tubes. The cogged extensions to the blind bolts were very effective in relieving the stress concentration on the thin tube wall. The tensile load can be shared between membrane action of the tube wall and anchorage of the cogged bars. Thus, by using the blind-bolted connections with cogged extensions to connect the beam flanges to the column, moment transfer between the beam and column can be effectively achieved within a structural frame of composite construction.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writers would like to thank Smorgon Steel Group for donation of steel tubes for testing; GFC Industries for performing the welding of the cogged extensions to the bolts; AJAX Engineered Fasteners for their technical support; and the Australian Earthquake Engineering Society for a partial student award.
References
Ajax Engineered Fasteners. (2002). “ONESIDE brochure.” B-N012 data sheet, Victoria, Australia.
American Concrete Institute. (ACI). (2002). Building code requirements for structural concrete (ACI 318-02) and commentary (ACI 318R-02), ACI Committee 318, Farmington Hills, Mich., 183–185.
ANSYS Inc. (2003). User’s manual, ANSYS documentation, version 8.1, Southpointe, Canonsburg, Pa.
Barnett, T., Tizani, W., and Nethercot, D. A. (2000). “Blind bolted moment resisting connections to structural hollow sections.” Proc., Connections in Steel Structures IV: Steel Connections in the New Millennium, AISC, Chicago, 340–348.
Comité Euro-International du Béton (CEB). (1993). CEB-FIP model code 1990, Thomas Telford, London, 82–86.
Eligenhausen, R., Popov, E. P., and Bertero, V. V. (1983). “Local bond stress-slip relationships of deformed bars under generalized excitations.” Rep. No. UCB/EERC-83/23, Earthquake Engineering Research Center, Univ. of California, Berkeley, Calif., 102.
France, J. E., Davison, J. B., and Kirby, P. A. (1999). “Moment-capacity and rotational stiffness of endplate connections to concrete-filled tubular columns with flowdrilled connectors.” J. Constr. Steel Res., 50(1), 35–48.
Fujimoto, T., Inai, E., Kai, M., Mori, K., Mori, O., and Nishiyama, I. (2000). “Behaviour of beam-to-column connection of CFT column system.” 12th World Conf. on Earthquake Engineering, Silverstream, Auckland, New Zealand.
Gardner, A. P., and Goldsworthy, H. M. (2005). “Experimental investigation of the stiffness of critical components in a moment-resisting composite connection.” J. Constr. Steel Res., 61(5), 709–726.
Goldsworthy, H., and Gardner, A. P. (2006). “Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns.” Struct. Eng. Mech., 24(4), 463–478.
Grigorian, C. E., and Popov, E. P. (1994). “Energy dissipation with slotted bolted connections.” Rep. No. UCB/EERC-94/02, Earthquake Engineering Research Center, Univ. of California, Berkeley, Calif.
Heath, D. J., Corvetti, J., Gad, E. F., and Wilson, J. L. (2004). “Development of a photogrammetry system to monitor building movement.” Proc., 2004 Conf., Australian Earthquake Engineering Society, Victoria, Australia.
Klippel, S. (1998). “Recent design developments with blind mechanically operated bolt systems for use with hollow section steelwork.” J. Constr. Steel Res., 46(1–3), 267–268.
Korol, R. M., Ghobarah, A., and Mourad, S. (1993). “Blind bolting W-shape beams to HSS columns.” J. Struct. Eng., 119(12), 3463–3481.
Nakada, K., and Kawano, A. (2003). “Load-deformation relations of diaphragm-stiffened connections between H-shaped beams and circular CFT columns.” Proc., Int. Conf. on Advances in Structures, G. J. Hancock et al., eds, Sydney, Australia.
Popov, E. P., Blondet, M., and Stepanov, L. (1996). “Application of dog bones” for improvement of seismic behaviour of steel connections.” Rep. No. UCB/EERC-96/05, Earthquake Engineering Research Center, Univ. of California, Berkeley, Calif.
Schneider, S. P., and Alostaz, Y. M. (1998). “Experimental behaviour of connections to concrete-filled steel tubes.” J. Constr. Steel Res., 45(3), 321–352.
Sherbourne, A. N., and Bahaari, M. R. (1996). “3D simulation of bolted connections to unstiffened columns. I: T-stub connection.” J. Constr. Steel Res., 40(3), 169–187.
Soroushian, P., Obaseki, K., Nagi, M., and Rojas, M. C. (1988). “Pullout behavior of hooked bars in exterior beam-column connections.” ACI Struct. J., 85(3), 269–276.
Standards Australia. (2001). Concrete structures, AS3600, Standards Association of Australia, NSW, 130.
Swanson, J. A., Kokan, D. S., and Leon, R. T. (2002). “Advanced finiteelement modelling of bolted T-stub connection components.” J. Constr. Steel Res., 58(5–8), 1015–1031.
Swanson, J. A., and Leon, R. T. (2000). “Bolted steel connections: Tests on T-stub components.” J. Struct. Eng., 126(1), 50–56.
Yang, T. S., and Popov, E. P. (1995). “Experimental and analytical studies of steel connections and energy dissipators.” Rep. No. UCB/EERC-95/13, Earthquake Engineering Research Center, Univ. of California, Berkeley, Calif.
Yao, H., Goldsworthy, H. M., and Gad, E. F. (2007). “Study on blind-bolted split tee connection to concrete-filled steel tubes for steel moment-frame buildings.” 4th Int. Structural Engineering and Construction Conf., Taylor & Francis, London, 119–126.
Information & Authors
Information
Published In
Copyright
© 2008 ASCE.
History
Received: Dec 6, 2006
Accepted: Aug 3, 2007
Published online: Feb 1, 2008
Published in print: Feb 2008
Notes
Note. Associate Editor: Scott A. Civjan
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.