Experimental Seismic Study of Adjacent Buildings with Fluid Dampers
Publication: Journal of Structural Engineering
Volume 129, Issue 2
Abstract
A comprehensive experimental investigation on the dynamic characteristic and seismic response of adjacent buildings linked by fluid dampers is carried out using a 4 m×4 m seismic simulator. Two building models are built as one five-story steel frame 5 m high and the other six-story steel frame 6 m high. The fluid dampers connecting the two building models are of linear force–velocity property. Two types of ground motions are applied to the adjacent buildings. The control performance of fluid dampers is first assessed through the comparison of the dynamic characteristic and seismic response of the adjacent buildings linked by fluid dampers with those linked by rigid rods or without any connections. The effects of the number, location, and linking pattern of fluid dampers and the effects of ground motion on control performance are then investigated. The first natural frequency ratio of the two building models is finally changed and its effect on control performance is evaluated. The experimental results show that the installation of fluid dampers can significantly reduce the seismic responses of both buildings. The number, location, and linking pattern of fluid damper, the frequency ratio of adjacent buildings, and the type of ground motion should be considered properly to achieve good control performance.
Get full access to this article
View all available purchase options and get full access to this article.
References
Christenson R. E., Spencer, B. F., and Johnson, E. A. (1999). “Coupled building control using active and smart damping strategies.” Proc., 5th Int. Conf. on Application of Artificial Intelligence to Civil Engineering and Structural Engineering, Civil-Comp Press, Edinburgh, Scotland, 187–195.
Constantinou, M. C., and Symans, M. D. (1993). “Experimental study of seismic response of buildings with supplemental fluid dampers.” The structural design of tall buildings, Vol. 2, 93–132.
Klein, R. G., and Healy, M. D. (1985). “Semiactive control of wind induced oscillations in structures.” Proc., 2nd Int. Conf. on Structural Control, Univ. of Waterloo, Ontario, Canada, 354–369.
Kobori, T., Yamada, T., Takenaka, Y., Maeda, Y., and Nishimura, I. (1988). “Effect of dynamic tuned connector on reduction of seismic response: Application to adjacent office buildings.” Proc., 9th World Conf. on Earthquake Engineering, Tokyo–Kyoto, Japan, Vol. 5, 773–778.
Luco, J. E.and De Barros, F. C. P.(1998). “Optimal damping between two adjacent elastic structures.” Earthquake Eng. Struct. Dyn., 27, 649–59.
Seto, T. and Matsumoto, Y. (1996). “A structural vibration control method of flexible buildings in response to large earthquakes and strong winds.” Proc., 2nd Int. Workshop on Structural Control, Hong Kong Univ. of Science and Technology, Hong Kong, 490–496.
Westermo, B.(1989). “The dynamics of interstructural connection to prevent pounding.” Earthquake Eng. Struct. Dyn., 18, 687–699.
Xu, Y. L., He, Q., and Ko, J. M.(1999). “Dynamic response of damper-connected adjacent buildings under earthquake excitation.” Eng. Struct., 21(2), 135–148.
Xu, Y. L., Zhan, S., Ko, J. M., and Zhang, W. S.(1999). “Experimental investigation of adjacent buildings connected by fluid damper.” Earthquake Eng. Struct. Dyn., 28, 609–631.
Xu, Y. L., and Zhang, W. S.(2002). “Closed-form solution for seismic response of adjacent buildings with LQG controllers.” Earthquake Eng. Struct. Dyn., 31(2), 235–259.
Zhang, W. S., and Xu, Y. L.(1999). “Dynamic characteristics and seismic response of adjacent buildings linked by discrete dampers.” Earthquake Eng. Struct. Dyn., 28, 1163–1185.
Zhang, W. S., and Xu, Y. L.(2000). “Vibration analysis of two buildings linked by Maxwell model-defined fluid dampers.” J. Sound Vib., 233, 775–796.
Information & Authors
Information
Published In
Copyright
Copyright © 2003 American Society of Civil Engineers.
History
Received: May 30, 2001
Accepted: May 1, 2002
Published online: Jan 15, 2003
Published in print: Feb 2003
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.