Experimental Study on Shear Splitting Failure of Full-Scale Composite Concrete Encased Steel Beams
Publication: Journal of Structural Engineering
Volume 128, Issue 9
Abstract
Presented herein is an experimental study that focuses on the shear splitting failure of composite concrete encased steel beams. Nine full-scale specimens were constructed and tested in this study. Significant horizontal cracks along the interface of steel flange and concrete, referred to as the shear splitting failure, appeared in five tested specimens. Observations from the experiments indicate that the steel flange width ratio, defined as the ratio of steel flange width to gross section width, has a dominant effect on the shear splitting failure of composite beams. The test results reveal that the shear splitting failure occurs when the steel flange width ratio of a composite beam reaches 0.67. The test results also show that the application of shear studs has a positive effect on preventing this type of failure for beams with large steel flange ratio. In addition to the experimental study, a new method for predicting the failure mode of composite beams is proposed. The proposed method gives satisfactory predictions as compared to the test results. Finally, a new equation is derived for the design of the stirrups to prevent shear splitting failure of naturally bonded composite beams.
Get full access to this article
View all available purchase options and get full access to this article.
References
ACI (1999). “Building code requirements for structural concrete (ACI 318-99) and commentary (ACI 318R-99)” ACI 318-99, Farmington Hills, Mich.
ACI-ASCE Committee 426 (1973). “The shear strength of reinforced concrete members.” J. Struct. Div. ASCE, 99(ST6), 1148–1157.
AIJ (2001). “Standards for structural calculation of steel reinforced concrete structures.” Architectural Institute of Japan, Tokyo.
AISC (1999). “Load and resistance factor design specification for structural steel buildings.” American Institute of Steel Construction, Chicago.
ASTM (1991a). “Standard methods for compression testing of cylindrical concrete specimens.” C39-72, Philadelphia.
ASTM (1991b). “Standard methods for tension testing of metallic materials.” E8-91, Philadelphia.
BSSC (1997). “NEHRP recommended provisions for the development of seismic regulations for new buildings and other structures.” National Earthquake Hazards Reduction Program, Building Seismic Safety Council, Washington, D.C.
El-Tawil, S., and Deierlein, G. G.(1999). “Strength and ductility of concrete encased composite columns.” J. Struct. Eng., 125(9), 1009–1019.
El-Tawil, S., Sanz-Picòn, C. F., and Deierlein, G. G.(1995). “Evaluation of ACI 318 and AISC (LRFD) strength provisions for composite beam-columns.” J. Constr. Steel Res., 34, 103–123.
Furlong, R. W.(1968). “Design of steel-encased concrete beam-columns,” J. Struct. Eng., 94(1), 267–281.
Hofbeck, J. A., Ibrahim, I. O., and Mattock, A. H.(1969). “Shear transfer in reinforced concrete.” ACI J., 66(2), 119–128.
Johnson, R. P., and May, I. M.(1978). “Tests on restrained composite columns.” Structural Engineers, London, 56B(2), June, 21–28.
Mattock, A. H., and Hawkins, N. M.(1972). “Shear transfer in reinforced concrete—recent research.” J. Prestressed Concr. Inst., 17(2), 55–75.
Mirza, S. A.(1989). “Parametric study of composite column strength variability,” J. Constr. Steel. Res., 14(2), 121–137.
Mirza, S. A., Hyttinen, V., and Hyttinen, E.(1996). “Physical tests and analyses of composite steel-concrete beam-columns.” J. Struct. Eng., 122(11), 1317–1326.
Muñoz, P. R., and Hsu, C.-T. T.(1997a). “Behavior of biaxial loaded concrete-encased composite columns.” J. Struct. Eng., 123(9), 1163–1171.
Muñoz, P. R., and Hsu, C.-T. T.(1997b). “Biaxial loaded concrete-encased composite columns: design equation.” J. Struct. Eng., 123(12), 1576–1585.
Naka, T., Morita, K., and Tachibana, M.(1977). “Strength and hysteretic characteristics of steel-reinforced concrete columns (Part 2).” Trans. AIJ, 250, 47–58.
Procter, A. N.(1967). “Tests on stability of concrete encased I-beams.” Consulting Engineer, London, England, Feb., 56–58, Mar., 59–61.
Ricles, J. M., and Paboojian, S. D.(1994). “Seismic performance of steel-encased composite columns.” J. Struct. Eng., 120(8), 2474–2494.
Roeder, C. W., Chmielowski, R., and Brown, C. B.(1999). “Shear connector requirements for embedded steel sections.” J. Struct. Eng., 125(2), 142–151.
Wakabayashi, M. (1987). “A historical study of research on composite construction in Japan.” Proc., Conf. Composite Construction in Steel and Concrete, ASCE, New York, 400–427.
Information & Authors
Information
Published In
Copyright
Copyright © 2002 American Society of Civil Engineers.
History
Received: Jun 15, 2001
Accepted: Jan 14, 2002
Published online: Aug 15, 2002
Published in print: Sep 2002
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.