Capacity of Oriented Strand Board Shear Walls with Overdriven Sheathing Nails
Publication: Journal of Structural Engineering
Volume 128, Issue 7
Abstract
Eight shear wall specimens sheathed with 11 mm structural oriented strand board panels were assembled with overdriven sheathing nails and tested using a pseudo-dynamic procedure. Specimens used 38×89 mm Douglas Fir-Larch framing members and 8d cooler, gun-driven sheathing nails. Four overdriven nail depths were considered: flush, 1.6, 3.2, and 4.8 mm. Nails were spaced at 76 mm on center along the edges and 305 mm on center along intermediate supports. Edge nailing distance was 9.5 mm. Two specimens were constructed for each aforementioned overdriven depth. To determine a lower bound on capacity, 100% of the sheathing nails in a specimen were driven to the specified depth. Results from this study indicate that any level of sheathing-nail overdrive will reduce the capacity of a shear wall. Compared to specimens with flush-driven nails, specimens with nails overdriven 1.6 mm suffered 5% loss in strength and gained 1% in displacement capacity. Specimens with nails overdriven 3.2 mm had strength and displacement capacity reduced by 12 and 22%, respectively. Specimens with nails overdriven 4.8 mm fared poorly; strength was reduced 24%, and displacement capacity was reduced 56%.
Get full access to this article
View all available purchase options and get full access to this article.
References
Advanced connector systems catalog. (1999). Advanced Connector Systems, Inc., Tempe, Ariz.
American Society for Testing and Materials (ASTM). (1997). “Standard test method for determining bending yield moment of nails.” ASTM F1575-95, Annual book of standards, Vol. 15.08, ASTM, Philadelphia.
APA. (1980). Plywood diaphragm specification, The Engineered Wood Association. Tacoma, Wash.
Andreason, K. A., and Tissell, J. R. (1994). “Effects of overdriven nails in shear walls.” Rep. No. T94-9, APA—The Engineered Wood Association, Technical Services Division, Tacoma, Wash.
Dinehart, D. W., and Shenton, H. W.(1998). “Comparison of static and dynamic response of timber shear walls.” J. Struct. Eng. 124(6), 686–695.
Dolan, J. D. (1999). “Code development for seismic design of woodframe structures: Testing needs. Proc., Invitational Workshop on Seismic Testing, Analysis and Design of Woodframe Construction, F. Seible, A. Filiatrault, and C. Uang, eds., Los Angeles, 9–14.
Ficcadenti, S. J., Castle, T. A., Sandercock, D. A., and Kazanjy, R. K. (1996). “Laboratory testing to investigate pneumatically driven box nails for the edge nailing distance of 3/8" thick plywood shear walls.” Proc., SEAOC 57th Annual Convention, Structural Engineers Association of California, San Francisco, 389–399.
Gray, R. G., and Zacher, E. G.(1988). “Dynamic testing of wood shear panels.” Architecture: AIA J. 77(3), 121–124.
Hall, J. F.(1996). “Northridge earthquake of January 17, 1994: Reconnaissance report, Volume 2.” Earthquake Spectra, 11, 125–176.
International Conference of Building Officials (ICBO). (1997). Uniform Building Code, Whittier, Calif.
Jones, S. N., and Fonseca, F. S. (2000). “Cyclic testing of oriented strand board shear walls with over-driven nails.” Rep. No. CES-00-03, Dept. of Civil and Environmental Engineering, Brigham Young Univ., Provo, Utah.
Karacabeyli, E., and Ceccotti, A. (1998). “Nailed wood-framed shear walls for seismic load: Test results and design considerations.” Proc., Structural Engineers World Congress, San Francisco, paper No. T207-6.
Krawinkler, H., Parisi, F., Ibarra, L., Ayoub, A., and Medina, R. (2000). “Development of a testing protocol for wood frame structures.” Draft Research Rep., CUREE-Caltech Woodframe Project Task 1.3.1.
National Evaluation Service Committee. (1997). “Power-driven staples and nails for use in all types of building construction.” Rep. No. NER-272, Council of American Building Officials.
Structural Engineers Association of Southern California (SEAOSC). (1997). Standard method of cyclic (reversed) load tests for shear resistance of framed walls for buildings, SEAOSC, Whittier, Calif.
Tissell, J. R. (1996). “Wood structural panel shear walls.” Rep. No. 165, APA—The Engineered Wood Association, Technical Services Division, Tacoma, Wash.
Uang, C. M., Filiatrault, A., Seible, F., and Gatto, K. (2001). “Rate of loading and loading protocol effects.” Draft Research Rep., CUREE-Caltech Woodframe Project Task 1.3.1.
Zacher, E. G., and Gray R. G. (1985). “Dynamic tests of wood framed shear walls.” Proc., SEAOC 57th Annual Convention, Structural Engineers Association of California, San Francisco, 41–61.
Zacher, E. G., and Gray, R. G. (1989). “Lessons learned from dynamic tests of shear panels.” Proc., Sessions Related to Design, Analysis and Testing at Structural Congress, A. H-S. Ang, ed., ASCE, New York, 134–142.
Information & Authors
Information
Published In
Copyright
Copyright © 2002 American Society of Civil Engineers.
History
Received: Oct 12, 2000
Accepted: Nov 18, 2001
Published online: Jun 14, 2002
Published in print: Jul 2002
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.