Balancing Lateral Loads Using Tendon-Based Supplemental Damping System
Publication: Journal of Structural Engineering
Volume 126, Issue 8
Abstract
A new design and retrofit concept that deals with the placement and functional attributes of dampers for the seismic protection of buildings is presented. The configuration for the proposed concept is referred to as load balancing prestressed tendon-fuse + damper system. The system is based on the notion of prestressed load-balancing and uses a combination of tendons, fuse-bars, and dampers; the latter preferably possessing recentering and preload characteristics. It is shown that the system has a direct effect in reducing the overturning moment demand on the main structural elements. The new approach is first contrasted with the concept that is currently used by designers and advocated in FEMA 273. Next, an overall strategy is presented for the various phases of the design process. This includes the facets of conceptual and preliminary design as well as the final design verification process. The efficacy of the preliminary design phase is improved by a well-conceived single-degree-of-freedom idealization of the structural system. The general normalized design parameters for the supplemental system are then transformed for the multi-degree-of-freedom system based on specific configuration details. Finally, the seismic design and evaluation of a nine-story steel building is presented as an example of the applicability of the proposed design algorithm and system configuration.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Chopra, A. K. (1995). Dynamics of structures: Theory and applications to earthquake engineering, Prentice-Hall, Englewood Cliffs, N.J.
2.
Federal Emergency Management Agency (FEMA). (1997). “NEHRP guidelines for the seismic rehabilitation of buildings.” FEMA 273 (Guidelines) and 274 (Commentary), Washington, D.C.
3.
Hall, J. F., Heaton, H. T., Marvin, W. H., and Wald, D. J. (1995). “Near-source ground motion and its effects on flexible buildings.” Earthquake Spectra, 11(4), 569–605.
4.
Kunnath, S. K., Reinhorn, A. M., and Lobo, R. F. (1992). “IDARC version 3.0: A program for the inelastic damage analysis of reinforced concrete structures.” Tech. Rep. NCEER-92-0022, National Center for Earthquake Engineering Research, Buffalo.
5.
Naeim, F., Skliros, K., Reinhorn, A. M., and Sivaselvan, M. V. (1998). “Effects of hysteretic deterioration characteristics on seismic response of moment resisting structures.” Rep. on Task 5.4.4 of System Performance Investigation of SAC Joint Venture, JAMA Rep. 98/8428.58, John A. Martin & Associates, Inc., Los Angeles.
6.
Pekcan, G. ( 1998). “Design of seismic energy dissipation systems for reinforced concrete and steel structures.” PhD dissertation, State University of New York at Buffalo, Buffalo.
7.
Pekcan, G., Mander, J. B., and Chen, S. S. (1995). “The seismic response of a 1:3 scale R.C. structure with elastomeric spring dampers.” Earthquake Spectra, 11(2), 249–267.
8.
Pekcan, G., Mander, J. B., and Chen, S. S. (1999a). “Fundamental considerations for the design of nonlinear viscous dampers.” Earthquake Engrg. and Struct. Dyn., 28(11), 1405–1425.
9.
Pekcan, G., Mander, J. B., and Chen, S. S. (1999b). “Design and retrofit methodology for building structures with supplemental energy dissipating systems.” Tech. Rep. MCEER-99-0021, Multidisciplinary Center for Earthquake Engineering Research, Buffalo.
10.
Pekcan, G., Mander, J. B., and Chen, S. S. (2000). “Experiments on steel MRF building with supplemental tendon system.”J. Struct. Engrg., ASCE, 126(4), 437–444.
11.
Prakash, V., Powell, G. H., and Filippou, F. C. (1992). “Drain-2DX: Base program user guide.” Rep. No. UCB/SEMM-92/99, University of California, Berkeley, Berkeley, Calif.
12.
Richter, P. J., Nims, D. K., Kelly, J. M., and Kallenbach, R. M. (1990). “The EDR—Energy dissipating restraint: A new device for mitigation of seismic effects.” Proc., 1990 SEAOC Convention.
13.
Tsopelas, P., and Constantinou, M. C. (1994). “NCEER-Taisei Corporation Research Program on sliding seismic isolation systems for bridges: Experimental and analytical study of a system consisting of sliding bearings and fluid restoring force/damping devices.” Tech. Rep. NCEER-94-0014, National Center for Earthquake Engineering Research, Buffalo.
Information & Authors
Information
Published In
History
Received: Jul 12, 1999
Published online: Aug 1, 2000
Published in print: Aug 2000
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.