Load Sharing Effects in Light-Frame Wood-Truss Assemblies
Publication: Journal of Structural Engineering
Volume 126, Issue 12
Abstract
Load sharing among repetitive wood members interconnected by structural sheathing strengthens light-frame assemblies beyond that assumed in designing a single member. A repetitive member factor of 1.15 applied to bending resistance has been traditionally included in wood design standards to account for this effect. The focus of this study was to quantify load-sharing effects on members in metal-plate-connected wood trusses. This was accomplished using a detailed structural analysis model and statistical characterizations of lumber stiffness and strength properties. Monte Carlo simulations were conducted on six common truss configurations and one dimension lumber joist floor where wood member properties were randomly selected from distributions representing properties of the lumber grade. The assemblies were analyzed with and without attached sheathing to directly quantify the load-sharing effects in the system. The computed mean load-sharing factors ranged from 1.06 to 1.24 in the truss assemblies and from 1.17 to 1.19 for the joist assembly. The load-sharing factors were found to be applicable to wood truss members subject to tensile or compressive forces in addition to bending forces.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
ASTM. ( 1999). “Standard practice for establishing structural grades and related allowable properties for visually graded lumber.” D 245-98, West Conshohocken, Pa.
2.
Bonnicksen, L. W., and Suddarth, S. K. ( 1966). “Structural reliability analysis of a wood load sharing system.” J. Mat., 1(3), 491–508.
3.
Bulleit, W. M., and Liu, W. (1995). “First-order reliability analysis of wood structural systems.”J. Struct. Engrg., ASCE, 121(3), 517–529.
4.
Cramer, S. M., Shrestha, D. K., and Mtenga, P. V. ( 1993). “Computation of member forces in metal plate connected wood trusses.” Struct. Engrg. Rev., Oxford, England, 5(3), 209–217.
5.
Criswell, M. E. ( 1983). “New floor design procedures.” Proc. 7317, Wall and Floor Sys: Des. and Perf. of Light-Frame Struct., Forest Products Research Society, Madison, Wis., 63–86.
6.
Folz, B., and Foschi, R. O. (1989). “Reliability-based design of wood structural systems.”J. Struct. Engrg., ASCE, 115(7), 1666–1680.
7.
Green, D. W., and Evans, J. W. ( 1987a). Mechanical properties of visually graded lumber: Volume 1. A summary (NTIS PB-88 159 389), U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, Madison, Wis.
8.
Green, D. W., and Evans, J. W. ( 1987b). Mechanical properties of visually graded lumber: Volume 4. Southern pine (NTIS #PB-88 159 413), U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, Madison, Wis.
9.
Liu, W., and Bulleit, W. M. (1995). “Overload behavior of sheathed lumber systems.”J. Struct. Engrg., ASCE, 121(7), 1110–1118.
10.
Load and resistance factor design manual for engineered wood construction. (1996). American Forest and Paper Association, Washington, D.C.
11.
McCarthy, M., and Wolfe, R. ( 1987). “Assessment of truss plate performance model applied to southern pine truss joints.” Res. Paper FPL-RP-483, U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, Madison, Wis.
12.
Mtenga, P. V., Cramer, S. M., Peyrot, A. H., and Wolfe, R. W. (1995). “System factors for light-frame wood truss assemblies.”J. Struct. Engrg., ASCE, 121(2), 290–300.
13.
National design specification for wood construction. (1997). American Forest and Paper Association, Washington, D.C.
14.
PDS—Plywood design specification. (1997). APA—The Engineered Wood Association, Tacoma, Wash.
15.
Philpot, T. A., Rosowsky, D. V., and Fridley, K. J. (1995). “Reliability of wood joist floor systems with creep.”J. Struct. Engrg., ASCE, 121(6), 946–954.
16.
Rosowsky, D., and Ellingwood, B. (1991). “System reliability and load-sharing effects in light-frame wood construction.”J. Struct. Engrg., ASCE, 117(4), 1096–1114.
17.
Stahl, D., Cramer, S., and Wolfe, R. ( 1996). “Behavior of metal plate connected trusses with square-end webs.” Forest Products J., 46(6), 78–84.
18.
Taylor, S. E., and Bender, D. A. ( 1991). “Stochastic model for localized tensile strength and modulus of elasticity in lumber.” Wood and Fiber Sci., 23(4), 501–519.
19.
Truss Plate Institute (TPI). ( 1995). “National standard for metal plate connected wood truss construction.” ANSI/TPI 1-1995, Madison, Wis.
20.
Wolfe, R. W. ( 1990). “Performance of light-frame redundant assemblies.” Proc., 1990 Int. Timber Engrg. Conf., H. Sugiyama, ed., Steering Committee of the International Timber Engineering Conference, 1, 124–131.
21.
Zahn, J. ( 1970). “Strength of multiple-member structures.” U.S. Dept. of Agr. Forest Service Res. Paper FPL 139, Madison, Wis.
22.
Zahn, J. (1986). “Design of wood members under combined load.”J. Struct. Engrg., ASCE, 112(9), 2109–2126.
Information & Authors
Information
Published In
History
Received: Aug 18, 1999
Published online: Dec 1, 2000
Published in print: Dec 2000
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.