Optimal Placement of Actuators and Sensors for Floor Vibration Control
Publication: Journal of Structural Engineering
Volume 126, Issue 12
Abstract
Lightweight floor systems are susceptible to excessive levels of vibration caused by occupant activities such as walking, dancing, and aerobics. Ongoing research utilizes active control to reduce vibration. Placement of multiple actuators and sensors for effective vibration control of flexible systems such as floors is a challenging task. The method proposed in this paper simultaneously determines optimal placements for multiple actuators, sensors, and appropriate output feedback gains of the controller. Instead of carrying out the controller design in the analog domain and then applying a transformation to arrive at a digital implementation, the proposed algorithm provides a digital controller directly. This allows lower sampling rates to be used at the implementation stage. To obtain faster settling times in the presence of external disturbances, a performance index that penalizes system states exponentially is utilized. The nonlinearities associated with actuator saturation due to force/stroke limitations is considered explicitly in the optimization. The proposed algorithm uses an interpolation scheme in case only partial knowledge of the mode shape is available. Hence it is applicable to a wider class of 2D structures that do not possess closed-form expressions for modal shapes and for which one has to resort to finite-element or experimental modal analysis.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Anderson, B. D. O., and Moore, J. B. ( 1990). Optimal control: Linear quadratic methods, Prentice-Hall, Upper Saddle River, N.J.
2.
Arbel, A. ( 1981). “Controllability measures and actuator placement in oscillatory systems.” Int. J. Cont., London, 33(3), 565–574.
3.
Balas, M. J. ( 1979). “Direct velocity feedback control of large space structures.” AIAA J. Guidance Control Dyn., 2(3), 252–253.
4.
Balas, M. J. ( 1982). “Trends in large space structures control theory: Fondest hopes, wildest dreams.” IEEE Tran. Auto. Contr., 27(3), 522–535.
5.
Gawronski, W., and Lim, K. B. ( 1996). “Balanced actuator and sensor placement for flexible structures.” Int. J. Cont., London, 65(1), 131–145.
6.
Grace, A. ( 1994). Optimization toolbox user's guide, for use with MATLAB, The Math-Works, Inc., Natick, Mass.
7.
Hanagan, L. M. ( 1994). “Active control of floor vibrations.” PhD dissertation, Charles E. Via Dept. of Civ. Engrg., Virginia Polytechnic Institute and State University, Blacksburg, Va.
8.
Hanagan, L. M., and Murray, T. M. (1997). “Active control approach for reducing floor vibrations.”J. Struct. Engrg., ASCE, 123(11), 1497–1505.
9.
Hanagan, L. M., and Murray, T. M. ( 1998). “Experimental implementation of active control to reduce annoying floor vibrations.” Engrg. J., 35(4), 123–127.
10.
Kondoh, S., Yatomi, C., and Inoue, K. ( 1990). “The positioning of sensors and actuators in the vibration control of flexible systems.” Int. J., Tokyo, Ser. III, 33(2), 145–162.
11.
Lancaster, P., and Salkauskas, K. ( 1986). Curve and surface fitting: An introduction, Academic, London.
12.
Lee, H.-K., Chen, S.-T., and Lee, A.-C. ( 1996). “Optimal control of vibration suppression in flexible systems via dislocated sensor/actuator positioning.” J. Frank. Inst., 333B(5), 789–802.
13.
Lenzen, K. H. ( 1966). “Vibration of steel joist—Concrete slab floors.” Engrg. J., 3(3), 133–136.
14.
Lewis, F. L. ( 1992). Applied optimal control and estimation: Digital design and implementation, Prentice-Hall, Upper Saddle River, N.J.
15.
Meirovitch, L. ( 1997). Principles and techniques of vibrations, Prentice-Hall, Upper Saddle River, N.J.
16.
Rao, S. S., Pan, T. S., and Venkayya, V. B. ( 1990). “Modeling, control and design of flexible structures: A survey.” Appl. Mech. Rev., Part I, 43(5), 99–117.
17.
Sakata, T., and Hosokawa, K. ( 1990). “Vibration of simply supported orthotropic rectangular plates reinforced by an intermediate beam support.” Int. J., Tokyo, Ser. III, 33(3), 297–303.
18.
Schulz, G., and Heimbold, G. ( 1983). “Dislocated actuator/sensor positioning and feedback design for flexible structures.” AIAA J. Guidance Control Dyn., 6(5), 361–367.
19.
Wilson, E. L., and Habibullah, A. ( 1992). SAP90 structural analysis user's manual, Computers and Structures, Inc., Berkeley, Calif.
Information & Authors
Information
Published In
History
Received: Aug 27, 1999
Published online: Dec 1, 2000
Published in print: Dec 2000
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.