Cyclic Testing of Steel Moment Connections Rehabilitated with RBS or Welded Haunch
Publication: Journal of Structural Engineering
Volume 126, Issue 1
Abstract
The effectiveness of using the reduced beam section (RBS) and welded haunch for seismic rehabilitation of pre-Northridge steel moment connections was investigated through cyclic testing of six full-scale specimens—three of them incorporated lightweight concrete slabs. Test results showed that, unless the low-toughness E70T-4 groove weld was replaced by notch-tough weld metal, introducing RBS to the beam bottom flange alone could not prevent brittle fracture in the groove weld of the top flange. The presence of a concrete slab or removing steel backing only improved the cyclic performance slightly. Although two RBS specimens with weld replacement performed well, a new type of ductile fracture along the “k” line of the beam was observed. With E70T-4 groove welds in place, however, the welded haunch specimens performed better than the RBS specimens. No brittle fracture occurred when the slab was present. The composite slab only increased the beam positive flexural strength by about 10%.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
ATC. (1992). “Guidelines for cyclic seismic testing of components of steel structures for buildings.” Rep. No. ATC-24, Applied Technology Council, Redwood City, Calif.
2.
Civjan, S., and Engelhardt, M. D. (1998). “Experimental investigation of methods to retrofit connections in existing seismic-resistant steel moment frames.” Summary Final Rep. to the National Institute of Standards and Technology, Phil M. Ferguson Struct. Engrg. Lab., University of Texas at Austin, Austin, Tex.
3.
Load and resistance factor design for structural steel buildings. (1993). American Institute of Steel Construction, Chicago, IL.
4.
SAC. (1996a). “Interim Guidelines Advisory No. 1.” Rep. No. SAC-96-03 (Rep. No. FEMA-267A), SAC Joint Venture, Sacramento, Calif.
5.
SAC. (1996b). “Technical report: Experimental investigations of beam-column subassemblies.” Rep. No. SAC-96-01, SAC Joint Venture, Sacramento, Calif.
6.
Salmon, C. G., and Johnson, J. F. (1996). Steel structures: Design and Behavior, 4th Ed., HarperCollins, New York.
7.
Uang, C.-M., and Bondad, D. (1996). “Static cyclic testing of pre-Northridge and haunch repaired steel moment connections.” Rep. No. SSRP-96/02, Div. of Struct. Engrg., University of California at San Diego, La Jolla, Calif.
8.
Uniform building code. (1985). International Conference of Building Officials, Whittier, Calif.
9.
Uniform building code. (1988). International Conference of Building Officials, Whittier, Calif.
10.
Youssef, N., Bonowitz, D., and Gross, J. (1995). “A survey of steel moment-resisting frame buildings affected by the 1994 Northridge earthquake.” Rep. No. NISTIR 5625, NIST, Gaithersburg, Md.
11.
Yu, Q.-S., Noel, S., and Uang, C.-M. (1997). “Experimental and analytical studies on seismic rehabilitation of pre-Northridge steel moment connections: RBS and haunch approaches.” Rep. No. SSRP-97/08, Div. of Struct. Engrg., University of California at San Diego, La Jolla, Calif.
12.
Yu, Q.-S., Uang, C.-M., and Gross, J. (2000). “Seismic rehabilitation design of steel moment connection with welded haunch.”J. Struct. Engrg., ASCE, 126(1), 69–78.
Information & Authors
Information
Published In
History
Received: Mar 2, 1999
Published online: Jan 1, 2000
Published in print: Jan 2000
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.